Question #1

After expanding a two-node AFF A300 cluster with two AFF A700 nodes, you observe latencies when data is accessed indirectly. The system node run -node -command netstat command shows retransmits and packet drops on the LIFs. The AFF A700 nodes with 40 Gbps and the AFF A300 connect with 10 Gbps to the cluster interconnect. You are using Cisco Nexus 3132Q cluster interconnect switches. You just updated to ONTAP 9.8 software.

In this scenario, what is causing this problem?

  • A . The 10 Gbps to 10 Gbps cluster Interconnect is creating a speed mismatch.
  • B . AFF A300 and AFF A700 node mixing Isnot supported in ONTAP 9.8 software.
  • C . The AFF A300 Is using an adapter card for the cluster Interconnect, but only onboard ports are supported.
  • D . There is an NXOS firmware mismatch, verify in the Interoperability Matrix (1MTJ for a supportedversion.

Reveal Solution Hide Solution

Correct Answer: A
Question #2

You created a new NetApp ONTAP FlexGroup volume spanning six nodes and 12 aggregates with a total size of 4 TB. You added millions of files to the FlexGroup volume with a flat directory structure totaling 2 TB, and you receive anout of apace error message on your host.

What would cause this error?

  • A . The maximum number of volume constituents has been reached in the ONTAP software.
  • B . All constituent volumes are full.
  • C . The inode limit is exceeded in the ONTAP software.
  • D . The maxdirsize Is exceeded in the ONTAP software.

Reveal Solution Hide Solution

Correct Answer: C
Question #3

A customer’s storage administrator Informs you about the deactivated Automatic Switchover (AUSO) feature on their MetroCluster IP environment.

What Information would you tell your customer in this scenario?

  • A . The AUSO feature cannot be activated due to a non-mirrored aggregate.
  • B . The AUSO feature is not available in Metrocluster IP installations by design.
  • C . A faulty link automatically deactivated the AUSO feature.
  • D . This is a configuration failure, you can activate that feature for the customer.

Reveal Solution Hide Solution

Correct Answer: A
Question #4

A system panic due to an "L2 watchdog timeout hard reset" error occurred. You have found a FIFO message in the SP log.

Which FIFO message Is useful for Investigating this Issue?

  • A . before NMI BBSP:C=00 L=00 FIFO: F3 F2 F1 F0 5 B2 0 0 0 80 20 E F E3 C0 C2 3 4 6 7 9 9 A
  • B . BIOS exit BBSP:C=2F L=20 FIFO: 2 C8 C9 C4 24 4 6 18 7 8 11
  • C . before Reset BBSP:C=00 L=00 FIFO:
  • D . ONTAP Shutdown BBSP:C=00 L=2F FIFO:

Reveal Solution Hide Solution

Correct Answer: A
Question #5

You have a customer complaining of long build times from their NetApp ONTAP-based datastores. They provided you packet traces from the controller and client. Analysis of these traces shows an average service response time of 1 ms. QoS outputconfirms the same. The client traces are reporting an average of 15 ms in the same time period.

In this situation, what would be your next step?

  • A . The cluster is responding slowly and requires further investigation using performance archives.
  • B . The client that reports high latency should be investigated.
  • C . The cluster interconnects should be investigated.
  • D . A sync core should be triggered.

Reveal Solution Hide Solution

Correct Answer: B
Question #6

You receive the "Unable to connect to the management gateway server"error when trying to connect to a node management IP.

In this situation, how do you determine whether core dumps are generated for the mgwd user space process?

  • A . Log in to the nodeshell using the node console and collect the core dumps from the nodeshell.
  • B . Log in to the service processor and collect the core dumps from the service processor.
  • C . Log in to the clustershell using the node console and collect the core dumps from the clustershell.
  • D . Log in to the systemshell and collect core dumps from thesystemshell.

Reveal Solution Hide Solution

Correct Answer: D
Question #7

Your customer mentions that they have accidentally destroyed both rootaggregates in their two-node cluster.

In this scenario, what are two actions that must be performed? (Choose two.)

  • A . Rejoin the second node to the re-created cluster.
  • B . Re-create the cluster from the local backup.
  • C . Install ONTAP from a USB device.
  • D . Re-create the cluster from the remote backup.

Reveal Solution Hide Solution

Correct Answer: A,C
Question #8

Which two automation methods does NetApp ONTAP Select support? (Choose two.)

  • A . REST
  • B . Anslble
  • C . Docker
  • D . PHP

Reveal Solution Hide Solution

Correct Answer: A,B
Question #9

You have a 2-node NetApp FAS2750 switchless cluster with twenty-four 1.8 TB disks that is experiencing performance issues.

Upon investigation, you discover severaltype B consistency points.

Referring to the exhibit, which corrective action would address these consistency points?

  • A . Create additional data LIFs.
  • B . Convert the 2-node switchless cluster to a 2-node switched cluster.
  • C . Add an additional shelf oftwenty-four 1.8 TB disks.
  • D . Replace the twenty-four 1.8 TB disks with twelve 4 TB disks.

Reveal Solution Hide Solution

Correct Answer: C
Question #10

You notice poor performance on your FlexGroup and execute the system node run -node * flexgroup show command for more Information. You notice the "Urge" column has non-zero values.

In this scenario, which statement is true?

  • A . The aggregate is completely full.
  • B . The constituent volumes are out ofInodes.
  • C . The data placement is uneven.
  • D . The constituent volumes are completely full.

Reveal Solution Hide Solution

Correct Answer: C

Question #11

A 2-node cluster hosts only NAS data UFs. Allnodes lose access to the cluster network.

Referring to the exhibit, which statement is correct?

  • A . Both nodes race to takeover the other, one node will takeover the other node.
  • B . No takeover event will occur and NAS data UFs will not be accessible.
  • C . All nodes in the cluster reset and NAS data UFs are not accessible after reboot.
  • D . NAS data UFs are accessible on only the node that has Epsilon.

Reveal Solution Hide Solution

Correct Answer: C
Question #12

You have a new VMware vSphere cluster with ESXI 7.0U2 hosts. The hosts are connected to a 4-node AFF A400 NetApp ONTAP9.8 cluster with FC LUNs. You have a requirement to identify and follow I/Os from each VM on the shared FC LUN-backed datastores for troubleshooting purposes.

In this scenario, which VMware feature Is supported by ONTAP software to accomplish this task?

  • A . Network I/O Control (NIOC)
  • B . Virtual machine ID (VMID)
  • C . Storage I/O Control (SIOC)
  • D . vSphere Cluster Services (vCLS)

Reveal Solution Hide Solution

Correct Answer: B
Question #13

The motherboard of Node-01 is being replaced. To perform this task, a takeover was Initiated from Node-02. Node-02 panics showing the string below.

PANIC; Permanent errors on all HA mailbox disks (while marshalling header) in SKprocess fnmbx_instanceWorker on release 9.5P8 (C)

What has happened in this situation?

  • A . While in maintenance mode, the sldiag device show command was executed.
  • B . While in maintenance mode, the fcadmin device_map command was executed.
  • C . While in maintenance mode, the HA_config show command was executed.
  • D . While in maintenance mode, the mailbox destroy local command was executed.

Reveal Solution Hide Solution

Correct Answer: D
Question #14

Your customer added a new DS4246 shelf to their FAS2750 single-node system and created a new aggregate on the new shelf. Two weeks later, they log into Active IQ and discover the Medium Impact error shown below.

Shelves with both connections via the same SAS path detected

Referring to the exhibit, which statement is correct?

  • A . In a FAS2750 system, the internal shelf is only seen on one path, and the external shelves are seen on two paths.
  • B . The cables are cabled Incorrectly on the SAS stack.
  • C . This situation is normal for a FA57750 single-node system.
  • D . Active IQ Is not aware of the shelf configuration for a single-node system.

Reveal Solution Hide Solution

Correct Answer: C
Question #15

Referring to the exhibit, what do you need to do to return the MetroCluster to a normal state?

  • A . Enter the metroclustor switchback command on Site B.
  • B . Enter the metrocluster switchback command on Site A.
  • C . Enter the storage failover giveback command on Site B.
  • D . Enter the storage failover giveback command on Site A.

Reveal Solution Hide Solution

Correct Answer: B
Question #16

Your customer has deployed a two petabyte NetAppONTAP FlexGroup volume across their 4-node ONIAP 9.8 cluster. They plan to store over three billion files. They want to prevent file 10 conflicts since files are placed into the FlexGroup volume.

In this scenario, which two NFS SVM parameters should be enabled? (Choose two.)

  • A . -v3-64bit-identifiers
  • B . -v4-fsid-change
  • C . -v3-fsid-change
  • D . -v4-64bit-idantifiers

Reveal Solution Hide Solution

Correct Answer: BD
Question #17

Your customer complains about missing volume snapshot copies on a SnapMlrror destination. While investigating this case, you notice an executed SnapMirror resync operation in the event logs of the system.

In this scenario, what Is the cause of this problem?

  • A . Newer Snapshot copies than the common snapshot that was chosen for resync were removed automatically at the destination.
  • B . The autodelete option removed Snapshot copies before the resync.
  • C . Snapshot copies were manually removed from the destination after the resync.
  • D . NetApp ON TAP System Manager removed these snapshot copies due to a snapshot schedule.

Reveal Solution Hide Solution

Correct Answer: A
Question #18

You receive the panic message shown in the exhibit.

In this scenario, which component should you troubleshoot first?

  • A . the PCI card in slot 3
  • B . the MetroCluster FC-Vl card in slot 6
  • C . the memory module in slot 1
  • D . the CPU

Reveal Solution Hide Solution

Correct Answer: D
Question #19

You are attempting to connect a NetApp ONTAP cluster to a very complex network that requires LIFs to fail over across subnets.

How would youaccomplish this task?

  • A . Configure an equal number of UFs on each subnet.
  • B . Configure VIP LIFs using OSPF.
  • C . Configure VIP LIFs using BGP.
  • D . Configure a I IF failover policy for each subnet inside a single broadcast domain.

Reveal Solution Hide Solution

Correct Answer: C
Question #20

Your customer wants to access a LUN on a FAS 8300 system from a VMware ESXi server through the FC protocol. They already created a new SVM, volume. LUN, and igroup for this purpose. The customer reports that the server’s FC HBA port Is online, but the LUN does not show up.

Referring to the exhibit, what is the reason for this problem?

  • A . The FC service has not been configured on the SVM.
  • B . The zoning on the FC switches Is Incorrect.
  • C . The LUN Is not mapped to the correct SCSI ID.
  • D . The esxserver igroup contains incorrect IQNs.

Reveal Solution Hide Solution

Correct Answer: C