A 2-node cluster hosts only NAS data UFs. Allnodes lose access to the cluster network.
Referring to the exhibit, which statement is correct?
- A . Both nodes race to takeover the other, one node will takeover the other node.
- B . No takeover event will occur and NAS data UFs will not be accessible.
- C . All nodes in the cluster reset and NAS data UFs are not accessible after reboot.
- D . NAS data UFs are accessible on only the node that has Epsilon.
You have a new VMware vSphere cluster with ESXI 7.0U2 hosts. The hosts are connected to a 4-node AFF A400 NetApp ONTAP9.8 cluster with FC LUNs. You have a requirement to identify and follow I/Os from each VM on the shared FC LUN-backed datastores for troubleshooting purposes.
In this scenario, which VMware feature Is supported by ONTAP software to accomplish this task?
- A . Network I/O Control (NIOC)
- B . Virtual machine ID (VMID)
- C . Storage I/O Control (SIOC)
- D . vSphere Cluster Services (vCLS)
The motherboard of Node-01 is being replaced. To perform this task, a takeover was Initiated from Node-02. Node-02 panics showing the string below.
PANIC; Permanent errors on all HA mailbox disks (while marshalling header) in SKprocess fnmbx_instanceWorker on release 9.5P8 (C)
What has happened in this situation?
- A . While in maintenance mode, the sldiag device show command was executed.
- B . While in maintenance mode, the fcadmin device_map command was executed.
- C . While in maintenance mode, the HA_config show command was executed.
- D . While in maintenance mode, the mailbox destroy local command was executed.
Your customer added a new DS4246 shelf to their FAS2750 single-node system and created a new aggregate on the new shelf. Two weeks later, they log into Active IQ and discover the Medium Impact error shown below.
Shelves with both connections via the same SAS path detected
Referring to the exhibit, which statement is correct?
- A . In a FAS2750 system, the internal shelf is only seen on one path, and the external shelves are seen on two paths.
- B . The cables are cabled Incorrectly on the SAS stack.
- C . This situation is normal for a FA57750 single-node system.
- D . Active IQ Is not aware of the shelf configuration for a single-node system.
Referring to the exhibit, what do you need to do to return the MetroCluster to a normal state?
- A . Enter the metroclustor switchback command on Site B.
- B . Enter the metrocluster switchback command on Site A.
- C . Enter the storage failover giveback command on Site B.
- D . Enter the storage failover giveback command on Site A.
Your customer has deployed a two petabyte NetAppONTAP FlexGroup volume across their 4-node ONIAP 9.8 cluster. They plan to store over three billion files. They want to prevent file 10 conflicts since files are placed into the FlexGroup volume.
In this scenario, which two NFS SVM parameters should be enabled? (Choose two.)
- A . -v3-64bit-identifiers
- B . -v4-fsid-change
- C . -v3-fsid-change
- D . -v4-64bit-idantifiers
Your customer complains about missing volume snapshot copies on a SnapMlrror destination. While investigating this case, you notice an executed SnapMirror resync operation in the event logs of the system.
In this scenario, what Is the cause of this problem?
- A . Newer Snapshot copies than the common snapshot that was chosen for resync were removed automatically at the destination.
- B . The autodelete option removed Snapshot copies before the resync.
- C . Snapshot copies were manually removed from the destination after the resync.
- D . NetApp ON TAP System Manager removed these snapshot copies due to a snapshot schedule.
You receive the panic message shown in the exhibit.
In this scenario, which component should you troubleshoot first?
- A . the PCI card in slot 3
- B . the MetroCluster FC-Vl card in slot 6
- C . the memory module in slot 1
- D . the CPU
You are attempting to connect a NetApp ONTAP cluster to a very complex network that requires LIFs to fail over across subnets.
How would youaccomplish this task?
- A . Configure an equal number of UFs on each subnet.
- B . Configure VIP LIFs using OSPF.
- C . Configure VIP LIFs using BGP.
- D . Configure a I IF failover policy for each subnet inside a single broadcast domain.
Your customer wants to access a LUN on a FAS 8300 system from a VMware ESXi server through the FC protocol. They already created a new SVM, volume. LUN, and igroup for this purpose. The customer reports that the server’s FC HBA port Is online, but the LUN does not show up.
Referring to the exhibit, what is the reason for this problem?
- A . The FC service has not been configured on the SVM.
- B . The zoning on the FC switches Is Incorrect.
- C . The LUN Is not mapped to the correct SCSI ID.