Network Appliance NS0-591 NetApp Certified Support Engineer – ONTAP Specialist Online Training
Network Appliance NS0-591 Online Training
The questions for NS0-591 were last updated at Jan 01,2025.
- Exam Code: NS0-591
- Exam Name: NetApp Certified Support Engineer - ONTAP Specialist
- Certification Provider: Network Appliance
- Latest update: Jan 01,2025
Refer to the exhibit.
A volume move operation has been initiated to move a volume named Mirrsrc from one aggregate to another. The operation failed with the error that is shown in the exhibit.
In this scenario, which statement is correct?
- A . Manually trigger the cutover process in order to restart the job.
- B . The volume move cannot be completed at this time because of high use on the node.
- C . There are too many snapshots on the source volume.
- D . Cancel and restart the volume move operation.
Refer to the exhibit.
You are troubleshooting a system in which the customer reports that aggregates on Stack 6c/12b are having slow response times from system NETAPP1CLUS-02.
Referring to the exhibit, which two statements are correct? (Choose two.)
- A . The aggregates have only one PHY running at six gigabits per second on 6c.
- B . PHY 2 is running at six gigabits per second; on system NETAPPCLUS-02, reseat IOM6 Module A
on Shelf 10. - C . The shelf module firmware is downrev; on system NETAPPCLUS-01, replace IOM6 Module A on
Shelf 10. - D . The aggregates have only one PHY running at six gigabits per second on 12b.
What is a major difference between NFSv3 and NFSv4.x?
- A . NFSv4.x is stateful, and NFSv3 is stateless.
- B . NFSv4.x requires an auxiliary protocol for status monitoring, and NFSv3 does not.
- C . NFSv4.x is stateless, and NFSv3 is stateful.
- D . NFSv4.x requires an auxiliary protocol for mounting, and NFSv3 does not.
A customer is attempting to move from NFSv3 to NFSv4 and reports that all attempts to mount using NFSv3 continue to be successful, however, all of their NFSv4 mount attempts fail with an "access denied" error.
Which two statements would cause this error? (Choose two.)
- A . The NFS server does not have NFSv4 enabled.
- B . The SVM’s root volume allows execute access for all users.
- C . The export policy applied to the data volume does not allow clients to access it using NFSv4.
- D . The export policy applied to the SVM’s root volume does not allow the NFSv4 clients to access it.
In a 4-node cluster, nodes 1 and 2 are an HA pair, and nodes 3 and 4 are an HA pair. The following error appears in the log.
In this scenario, which two statements are correct? (Choose two.)
- A . All LUNs are offline in the cluster.
- B . All LUNs are online in the cluster.
- C . Node 1 takes over node 2.
- D . Node 2 takes over node 1.
Refer to the exhibit.
The storage administrator for the company exampie.com is attempting to join an SVM to their Active Directory as svmi. The computer account must also be joined to the secure organizational unit. Attempts to perform this action using the CLI fail with the error message shown in the exhibit.
What is a reason for this error?
- A . The requested OU Secure does not exist in the Active Directory and must be created by the Active Directory administrator.
- B . The requested OU Secure has the incorrect principal and errored with KRB5KDC_ERR_S_PRINCIPAL_UNKNOWN.
- C . The administrator account password used in vserver cifs create was not entered correctly.
- D . The syntax is incorrect; it should be vserver cifs create -cifs-server svml -domain example.com -ou ou=Secure,dc=example,dc=com.
Refer to the exhibit.
You are investigating an AutoSupport Disk Redundancy Failed alert. Cluster A lost connectivity to storage bridge BrB1, while cluster B lost connectivity to storage bridge BrA1.
Referring to the exhibit, which three components need investigation? (Choose three.)
storage bridges BrB1
- A . FC switch SwA1
- B . FC switch SwB1
- C . FC switch SwA2
- D . ISL cables
Two weeks ago, your customer experienced a data center outage, which caused their MCC to switch over. When the power was restored, they found that 14 disks over three RAID groups had failed, which caused two data aggregates to lose their mirror plexes.
In this situation, before you perform a switchback, which three actions should be taken? (Choose three.)
- A . Delete the failed plexes.
- B . Initiate the aggregate healing phases.
- C . Adjust bridge configuration for the replaced disks.
- D . Mirror the unmirrored aggregates.
- E . Assign all disks on the remote site to the surviving nodes.
After you replaced the motherboard, the node stopped in the "waiting for the cluster application to come online" state.
Which two actions would you perform to troubleshoot this problem? (Choose two.)
- A . Check the status of the HA with the interconnect-up field of storage faiiover show command.
- B . Verify the setting of the cluster interconnect switch.
- C . Verify that the physical links on the cluster ports are up.
- D . Check the status of the cluster with the cluster ring show command.
For restore purposes, a storage administrator on an ONTAP system created a FlexClone of a volume that contains a LUN from a specific snapshot. This LUN cannot be seen by a Windows client after a disk rescan is performed by using Disk Management.
In this scenario, which statement is correct?
- A . The cloned LUN must be brought online.
- B . The cloned LUN needs to be mapped to an initiator group.
- C . The cloned volume must be split from the source volume before the LUN can be used.
- D . The cloned LUN must be renamed to a different name than the name of the source LUN.d