Network Appliance NS0-184 NetApp Certified Storage Installation Engineer, ONTAP Online Training
Network Appliance NS0-184 Online Training
The questions for NS0-184 were last updated at Nov 23,2024.
- Exam Code: NS0-184
- Exam Name: NetApp Certified Storage Installation Engineer, ONTAP
- Certification Provider: Network Appliance
- Latest update: Nov 23,2024
After completing an installation, the customer wants to know how they can manually open a new technical case with NetApp Global Support.
What are three ways to accomplish this task? (Choose three.)
- A . Use the support site.
- B . Use the NetApp Field Portal.
- C . Use the mobile app.
- D . Use a telephone.
- E . Use AutoSupport.
You completed the installation of an AFF A700s with NetApp CN1610 switches. You used ports e0a and e0f with breakout cables to connect the controllers to the interconnect switches. After completing the cluster setup, ports e0e and e0i are not visible in OnCommand System Manager.
In this scenario, what caused this problem?
- A . Breakout cables were used and the second port on the same ASIC became disabled.
- B . This is a hardware error and you must open a case with NetApp Support.
- C . You must first enable the ports using the network port modify command.
- D . You are missing a license to enable those ports.
Which switch vendor is supported for the cluster network switches?
- A . Juniper Networks
- B . Cisco
- C . Brocade
- D . Hewlett-Packard
You want to add two new nodes to an existing 4-node cluster.
In this situation, what must be considered regarding the cluster interconnect?
- A . When a new node joins a cluster, IP addresses are generated automatically
- B . When a new node joins a cluster, IP addresses are used from the data LIF.
- C . When a new node joins a cluster, the customer must give you IP addresses from the customer’s local IP range.
- D . When a new node joins a cluster, you must use "class A" subnet settings.
An iSCSI LIF fails to migrate during a storage failover test. In this scenario, why did the LIF not migrate?
- A . A failover port was not defined
- B . LIFs that serve block protocols do not failover
- C . The failover policy was not configured
- D . LIF failover was not enabled
Click the Exhibit button.
You are asked to install a new cluster with six FAS8060 nodes. While running Config Advisor, you see the messages shown in the exhibit. The customer does not want ACP cabled on their cluster.
Which two actions would allow the installation to be completed successfully? (Choose two.)
- A . Advise NGS that the customer has a controller in an unsupported state.
- B . Advise the customer that they must acknowledge that they are not using ACP on the installation.
- C . Advise the sales team that the customer is operating without ACP and that the customer is asking you to leave it that way.
- D . Advise the customer that the error will cause the controller to not operate properly and create an unsupported state.
A new AFF8200 has a four-port UTA2 adapter installed in slot 2. Using the ucadmin command, you see that these ports are configured for FC.
Which port names are correct in this scenario?
- A . e0a/0a, e0b/0b, e0c/0c, e0d/od
- B . e2a/2a, e2b/2b, e2c/2c, e2d/2d
- C . e2a, e2b, e2c, e2d
- D . 2a, 2b, 2c, 2d
When you start a new Service Event Report, what must be entered first?
- A . the case ID number
- B . the project number
- C . the node serial number
- D . the sales order number
What is the main function of ACP?
- A . it allows cabling the shelf to two additional controllers.
- B . It allows the controller to use Ethernet instead of SAS to fetch the storage data.
- C . it allows the controller to nondisruptively reset the SAS expanders.
- D . It enables the automatic shelf ID assignment.
You have a 2-node switchless cluster named clusterA. You are planning on adding two additional nodes to clusterA.
What must you consider before you add the addiHonal nodes to clusterA?
- A . Convert clusterA to a switched cluster by migrating the data lIFs from direct connect to die cluster interconnect switch.
- B . Convert clusterA to a single-node cluster.
- C . Convert clusterA to a switch** cluster by migrating the cluster LIFs from direct connect to the cluster interconnect switch.
- D . Use direct connect to add the additional nodes to clusterA.