When performing a hardness test on a coating which has elastic properties the inspector is likely to likely to observe:
When performing a hardness test on a coating which has elastic properties the inspector is likely to likely to observe:A . A very high readingB . A very low readingC . Cold flow or creepD . No difference from any other coatingView AnswerAnswer: C
You are a NACE Level 2 Coating Inspector who has just arrived on a job in progress where there is no Inspection and Test Plan (ITP). The first morning you arrive the job is behind schedule and you are asked to take DIY Film Thickness readings.
You are a NACE Level 2 Coating Inspector who has just arrived on a job in progress where there is no Inspection and Test Plan (ITP). The first morning you arrive the job is behind schedule and you are asked to take DIY Film Thickness readings. Your FIRST preferred course...
WJ-1 is always performed using UHWJ at pressures above 210 MPa (30,000 PSI)
WJ-1 is always performed using UHWJ at pressures above 210 MPa (30,000 PSI)A . TrueB . FalseView AnswerAnswer: A
You are working as the only in-house NACE Level 2 Inspector in a shop setting when an independent 3 rd party NACE Level 3 Inspector, representing the owner, presents you with a copy of a Non Conformance Report (NCR) he has written for a NACE2/SSPC SP 10 centrifugal blast which you had previously approved.
You are working as the only in-house NACE Level 2 Inspector in a shop setting when an independent 3 rd party NACE Level 3 Inspector, representing the owner, presents you with a copy of a Non Conformance Report (NCR) he has written for a NACE2/SSPC SP 10 centrifugal blast which...
When measuring the Dry Film Thickness Of liquid coatings applied to galvanized ferrous substrates the most commonly used instrument is the:
When measuring the Dry Film Thickness Of liquid coatings applied to galvanized ferrous substrates the most commonly used instrument is the:A . Ultra Sonic DFT GaugeB . Tooke GaugeC . Eddy Current GaugeD . Magnetic GaugeView AnswerAnswer: B
You are the NACE Coating Inspector on a tank lining project and are asked to perform a high voltage holiday test after the coating applicators have completed their final repairs. After meeting all the confined space entry permit you enter the tank and notice a very strong odor of solvent.
You are the NACE Coating Inspector on a tank lining project and are asked to perform a high voltage holiday test after the coating applicators have completed their final repairs. After meeting all the confined space entry permit you enter the tank and notice a very strong odor of solvent....
The coating applicator has ignored a enface preparation hold point and applied coating over the surface without a sign off from you as the inspector.
The coating applicator has ignored a enface preparation hold point and applied coating over the surface without a sign off from you as the inspector. Your FIRST preferred course of action is to:A . Stop the jobB . Require the Applicator to remove the coatingC . Advise the Owner and...
External coatings applied to buried pipelines are generally tested for:
External coatings applied to buried pipelines are generally tested for:A . Gloss levelB . Chalking resistanceC . Cathodic disbondmentD . Solvent resistanceView AnswerAnswer: C
You are working as an inspector in a galvanizing plant for the first time.
You are working as an inspector in a galvanizing plant for the first time. What are some of the hazards you need to be aware of:A . Risk of chemical exposureB . Risk of skinC . Risk of acid or caustic splashesD . a), b), and c)View AnswerAnswer: D
An Inspection and Test Plan is required when:
An Inspection and Test Plan is required when:A . It is always requiredB . When the Coating Applicator requests oneC . When the Owner specifies oneD . When the Inspector requests oneView AnswerAnswer: A