NACE NACE-CIP1-001 Coating Inspector Level 1 Online Training
NACE NACE-CIP1-001 Online Training
The questions for NACE-CIP1-001 were last updated at Nov 20,2024.
- Exam Code: NACE-CIP1-001
- Exam Name: Coating Inspector Level 1
- Certification Provider: NACE
- Latest update: Nov 20,2024
When performing tests for oil and grease using an ultra-violet light, the NACE Inspector should be aware that:
- A . Chloride salt may produce a false positive
- B . Synthetic oil or grease may not be identified
- C . Ultra-Violet light may contaminant the surface
- D . Presence of weld spatter may produce a false positive
To achieve consistently accurate results with ALL alt test equipment
- A . wear gloves when sampling.
- B . wash your hands before sampling.
- C . avoid placing the sample discs on a surface.
- D . calibrate the instrument in the field.
When holiday testing is required the Inspector is always required to enforce NACE SP 0188:
- A . True
- B . False
If the specifier does not identify a restriction level in accordance with SSPC PA 2, the default restriction level is:
- A . Level 1
- B . Level 2
- C . Level 3
- D . Level 4
Fine cracks in the surface of a coating that rarely reach the substrate are called
- A . cracking.
- B . alligatoring.
- C . checking.
- D . blistering.
It is good practice for the NACE Inspector to have instrument calibration certificates available:
- A . At all times
- B . In the office only
- C . In the field only
- D . Only if the specification requires it
In a non-convertible coating the role of the primary solvent is to:
- A . To make the coating flow out better
- B . To dissolve the resin
- C . To promote faster cure
- D . To control the evaporation rate
Removal of welds splatter is required:
- A . On every job
- B . When ISO abrasive blast standards are specified
- C . When NACE/SSPC abrasive blast standards are specified
- D . When specifically identified in the owner’s specification
Common errors that may produce inaccurate readings when using a Dial-Type Magnetic Pull-Off Dry Filth Thickness (DFT) gauge include:
Select All That Apply
- A . Failing to determine the base metal reading (BMR)
- B . Rotating the dial too fast when taking measurements
- C . Taking measurements too far from the edge of a surface
- D . Measuring ditty, tacky, or soft films
Conventional spray is a good choice when:
- A . High production rates are required
- B . High quality finishes are required
- C . High transfer efficiency is required
- D . High viscosity coatings are being applied
If you haven’t done the practical training, then you have to do it and pass the practical exam. Then you will take a (Computer Base Training)written exam online after. Once you pass this two stages, then you will get Certification, and a license to do inspection.
what more do I need to do to get nace level 1 inspector certification once I pass the online study and test? is there some other testing facility I will have to attend or am I immediately eligible to hire out and begin inspecting?