In the Smartlogger WebUI interface, when the “Active Power Control” parameter is configured as “Enable”, the Smartlogger can perform active power control on the managed inverter.
In the Smartlogger WebUI interface, when the “Active Power Control” parameter is configured as “Enable”, the Smartlogger can perform active power control on the managed inverter.A . TrueB . FalseView AnswerAnswer: A
Huawei's SUN2000 inverter communicates by PLC mode when the baud rate defaults to ().
Huawei's SUN2000 inverter communicates by PLC mode when the baud rate defaults to ().A . 400bpsB . 9600bpsC . 1900bpsD . 115200bpsView AnswerAnswer: D
Which components should you use for data ingestion and data preparation?
HOTSPOT You are designing a solution that will analyze bank transactions in real time. The transactions will be evaluated by using an algorithm and classified into one of five groups. The transaction data will be enriched with information taken from Azure SQL Database before the transactions are sent to the...
When installing the AC line of the Huawei SUN2000 inverter, it is recommended that the stripping length of the insulation layer be 2mm~3mm longer than the crimping area of the OT terminal sub cable for convenient wiring. After pressing the terminal, the place of line needs to be covered with a heat shrinkable T bush or insulating rubber tape.
When installing the AC line of the Huawei SUN2000 inverter, it is recommended that the stripping length of the insulation layer be 2mm~3mm longer than the crimping area of the OT terminal sub cable for convenient wiring. After pressing the terminal, the place of line needs to be covered with...
The device that cannot be upgraded by the NetEco1000S system for remote software is ()
The device that cannot be upgraded by the NetEco1000S system for remote software is ()A . SmartLogger 1000B . SmartLogger 2000C . SUN2000 inverterD . Environmental monitorView AnswerAnswer: D
Huawei Smart Array Controller SmartACU2000B is recommended to be larger than () mm from the ground when installing.
Huawei Smart Array Controller SmartACU2000B is recommended to be larger than () mm from the ground when installing.A . 200B . 300C . 500D . 600View AnswerAnswer: D
The incoming and outgoing line mode of Huawei's intelligent sub-array controller SmartACU2000B adopts up-out and down-in.
The incoming and outgoing line mode of Huawei's intelligent sub-array controller SmartACU2000B adopts up-out and down-in.A . TrueB . FalseView AnswerAnswer: B
EHS includes environmental, occupational health and safety. Among them, occupational safety is the most important. Personnel behavior can neglect the impact on the environment and occupational health under the premise of ensuring safety.
EHS includes environmental, occupational health and safety. Among them, occupational safety is the most important. Personnel behavior can neglect the impact on the environment and occupational health under the premise of ensuring safety.A . TrueB . FalseView AnswerAnswer: B
Which of the following inverter parameters can be modified by the advanced user login Huawei SUN2000 APP?
Which of the following inverter parameters can be modified by the advanced user login Huawei SUN2000 APP?A . Secondary overvoltage protection pointB . Secondary undervoltage protection pointC . Primary overvoltage protection pointD . Insulation resistance protection pointView AnswerAnswer: D
Which of the following design is not suitable for a mountain photovoltaic power station system?
Which of the following design is not suitable for a mountain photovoltaic power station system?A . Subarray capacity adaptation terrain designB . Component spacing design is tailored to local conditions, reducing occlusionC . Keep the equipment away from the transformer box and use the mountain road for maintenance.D . Design...