- All Exams Instant Download
During Huawei OceanStor Kunpeng V5 and Dorado V6 controller expansion, which switch is used for controller inter-connection?
During Huawei OceanStor Kunpeng V5 and Dorado V6 controller expansion, which switch is used for controller inter-connection?A . IP switchB . PCle switchC . FC switchD . WAN switchView AnswerAnswer: C
Which storage technologies provide redundancy protection?
Which storage technologies provide redundancy protection?A . RAID 0B . RAID 5C . RAID 10D . RAID 1View AnswerAnswer: BCD
In NAS cross-protocol access, the Windows permission is the same as the Linux permission.
In NAS cross-protocol access, the Windows permission is the same as the Linux permission.A . TrueB . FalseView AnswerAnswer: B
Which between NVMe (PCle) and NVMe-oF (RoCE v2) features better scalability?
Which between NVMe (PCle) and NVMe-oF (RoCE v2) features better scalability?A . NVMe-oF (RoCE v2)B . NVMe (PCle)View AnswerAnswer: B
Which of the following are NOT true about OceanStor Dorado V6?
Which of the following are NOT true about OceanStor Dorado V6?A . Tolerance for failures of 7 out of 8 controllers for every modelB . NVMe available for every model.C . Up to 20 million IOPSD . As low as 1 ms latencyView AnswerAnswer: B
The recovery time objective (RTO) in a disaster recovery system refers to the time point to which the system and data must be recovered after a disaster occurs.
The recovery time objective (RTO) in a disaster recovery system refers to the time point to which the system and data must be recovered after a disaster occurs.A . TrueB . FalseView AnswerAnswer: A
What is the specification of the OceanStor Dorado V6 high-end controller?
What is the specification of the OceanStor Dorado V6 high-end controller?A . 3 controllers per 3uB . 4 controllers per 4uC . 4 controllers per 3UD . 2 controllers per 2uView AnswerAnswer: B
Which features would you recommend to the customer?
A customer wants to purchase an object storage system for use of different departments. These departments are independent and one cannot access the data of another. The expenses are shared by the departments. Which features would you recommend to the customer?A . BillingB . ReplicationC . QuotaD . Multi-tenantView AnswerAnswer:...
To reduce costs, general-purpose servers are commonly used for object storage.
To reduce costs, general-purpose servers are commonly used for object storage.A . TrueB . FalseView AnswerAnswer: B
Which product models can tolerate the failure of three out of four controllers?
Which product models can tolerate the failure of three out of four controllers?A . OceanStor 6800 V5 KunpengB . OceanStor 5600 V5 KunpengC . OceanStor 18000 v5 KunpengD . OceanStor 5800 vs KunpengView AnswerAnswer: ABCD