Now you need the data stored on the relocation to OceanStor 18000, using the array side data migration function is completed, which of the following statement are correct?

Customers can now network database services running on a storage OceanStor V3 database using a total of six LUN. Now you need the data stored on the relocation to OceanStor 18000, using the array side data migration function is completed, which of the following statement are correct? (Multiple choice)A ....

February 19, 2019 No Comments READ MORE +

Smart Matrix architecture is a multi-network control system architecture that Huawei design according to the enterprise data centers core storage system, based on the principles of Smart Matrix, Huawei OceanStor 18000 supports up to 16 engines (32 controller) clusters.

Smart Matrix architecture is a multi-network control system architecture that Huawei design according to the enterprise data centers core storage system, based on the principles of Smart Matrix, Huawei OceanStor 18000 supports up to 16 engines (32 controller) clusters.A . TRUEB . FALSEView AnswerAnswer: B

February 16, 2019 No Comments READ MORE +

When the OceanStor SNS switch is bound to a port, if the port bound to the license has a physical fault, the license of the port can’t be moved to another port that is not activated and continues to be used.

When the OceanStor SNS switch is bound to a port, if the port bound to the license has a physical fault, the license of the port can’t be moved to another port that is not activated and continues to be used.A . TrueB . FalseView AnswerAnswer: B

February 15, 2019 No Comments READ MORE +

In the process of engineers carry out storage array controller replacement operations, which of the following description is wrong?

In the process of engineers carry out storage array controller replacement operations, which of the following description is wrong?A . Prior to plug the controller, make sure that the business has stopped or has switched to the peer controller.B . before change the business to the opposite end controller, be...

February 15, 2019 No Comments READ MORE +

The advantages of heterogeneous virtualization migration are: (Multiple choice)

The advantages of heterogeneous virtualization migration are: (Multiple choice)A . Fast migration rateB . Uninterrupted businessC . Applicable to all scenariosD . Do not occupy host resourcesView AnswerAnswer: AD

February 14, 2019 No Comments READ MORE +

In the process of engineers carry out storage array controller replacement operations, which of the following description is wrong?

In the process of engineers carry out storage array controller replacement operations, which of the following description is wrong?A . Prior to plug the controller, make sure that the business has stopped or has switched to the peer controller.B . before change the business to the opposite end controller, be...

February 13, 2019 No Comments READ MORE +

In the OceanStor V3 storage system, when NAS file system performs NDMP backup, the backup IP changes. What operations need to be performed to make the backup service run normally? (Multiple choice)

In the OceanStor V3 storage system, when NAS file system performs NDMP backup, the backup IP changes. What operations need to be performed to make the backup service run normally? (Multiple choice)A . Log in DeviceManager, change the backup IP address to the latest backup IP address, and restart the...

February 11, 2019 No Comments READ MORE +

When installing SimPana, the server, which installed the client proxy, has two network cards which has configured IP, how the administrator set up to make the backup tasks communications through the specified IP?

When installing SimPana, the server, which installed the client proxy, has two network cards which has configured IP, how the administrator set up to make the backup tasks communications through the specified IP?A . Add data interface correctlyB . Configure the firewallC . Add host analysisD . Configure host routeView...

February 11, 2019 No Comments READ MORE +

Dual-control 5500V3 online migration S2600 storage, when the migration rate selects "medium speed", what is the maximum migration rate?

Dual-control 5500V3 online migration S2600 storage, when the migration rate selects "medium speed", what is the maximum migration rate?A . 28OMB/SB . 15OMB/SC . 80OMB/SD . 40OMB/SView AnswerAnswer: A

February 11, 2019 No Comments READ MORE +

Which of the following scenarios will cause Oceanstor 18000 to initiate local refactoring? (Multiple choice)

Which of the following scenarios will cause Oceanstor 18000 to initiate local refactoring? (Multiple choice)A . Hard disk failureB . The system detects CK that can’t be repairedC . Insert the drive back within two minutes after it is removed.D . IO access returns SECTOR FAULT errorView AnswerAnswer: BD

February 10, 2019 No Comments READ MORE +