Huawei H13-531_V2.0-ENU HCIE-Cloud Computing (Written) Online Training
Huawei H13-531_V2.0-ENU Online Training
The questions for H13-531_V2.0-ENU were last updated at Dec 25,2024.
- Exam Code: H13-531_V2.0-ENU
- Exam Name: HCIE-Cloud Computing (Written)
- Certification Provider: Huawei
- Latest update: Dec 25,2024
FusionCompute uses IP SAN storage, and the disk creation fails probabilistically. Which of the following may cause this failure?
- A . Data consistency check is enabled on the storage resource
- B . Incorrect VLAN ID setting on the storage interface
- C . LUN has bad blocks
- D . No independent network plane is configured to carry virtualized SAN storage heartbeat traffic
Company A plans to deploy a large number of linked clone desktops and use an OceanStor 5500 as the back-end storage. Which disk solution is more suitable?
- A . 50 2TB SATA disks form a storage pool, using RAID5 type internally
- B . 100 1TB SATA disks form a storage pool, using RAID5 type internally
- C . 50 2TB SATA disks form a storage pool, using RAID6 type internally
- D . 100 1TB SATA disks form a storage pool, using RAID6 type internally
Regarding the description of FusionCompute’s virtual machine live migration, which of the following is correct?
- A . Virtual machines configured with iCache can be live migrated
- B . The CPU of the source host and the target host are incompatible. After enabling the IMC mode in the cluster, the virtual machine migration will fail.
- C . Full migration of virtual machines with "shared" type disks mounted is not supported
- D . FusionCompute only supports virtual machine live migration based on shared storage
When using Rainbow to migrate, the source end can be a physical server, VMware or Hyper-V virtualization platform, and the destination end can be the FusionSphere platform.
- A . TRUE
- B . FALSE
In the FusionSphere private cloud solution, the mongodb service is abnormal due to the abnormal power failure of a host. At this point, you can clear the mongodb ERROR node data, restart mongodb, and automatically synchronize the data to complete the recovery.
- A . TRUE
- B . FALSE
If a storage device is configured with 8 1Gb/s iSCSI storage network cards, and the network bandwidth loss is 15%, which of the following methods can calculate the effective bandwidth (Mb/s) of the storage device?
- A . 8x1024x0.15
- B . 8x1024x1024x0.15
- C . 8x1024x (1-0.15)
- D . 8x1024x1024x (1-0.15)
Huawei ManageOne ServiceCenter provides several default service templates. Regarding the description of service templates, which of the following is incorrect?
- A . The cloud disk instance can be mounted on the running cloud host instance
- B . Unified management of computing, storage and network resources in VDC (Virtual Data Center)
- C . In the general cloud hosting service, support custom host name, key pair, password and other advanced properties
- D . An elastic IP address is a static, public IP address that can associate an elastic IP address with a cloud host
When hardware deployment of the FusionSphere server virtualization cloud platform, which of the following is the recommended hardware deployment sequence from bottom to top in the cabinet?
- A . Storage – Server – Switch
- B . Storage – Switch – Server
- C . Server – Storage – Switch
- D . Server – Switch – Storage
Which of the following roles will not be included in the FusionSphere OpenStack control node?
- A . measure
- B . database_keystone
- C . vcenter-proxy
- D . ceilometer
Configure FusionCompute, if the binding mode of the network card of the CNA host is set to load balancing, the connected switch port must be port aggregation; if the binding mode of the network card of the CNA host is active and standby, the connected switch port must be configured LACP protocol.
- A . TRUE
- B . FALSE