Site icon Exam4Training

HP HPE2-T37 Using HPE OneView Online Training

Question #1

What is a network set?

  • A . It is a collection of all internal networks defined for a specific type of traffic like vSAN or vMotion.
  • B . It is a collection of untagged Ethernet networks that form a named group to simplify server profile creation.
  • C . It is a collection of tagged Ethernet networks that form a named group to simplify server profile creation.
  • D . It is a collection of all networks configured within HPE OneView regardless of network type.

Reveal Solution Hide Solution

Correct Answer: B
Question #2

what is required to add a remote frame to the primary management ring?

  • A . UUD of the remote HPE Composer
  • B . Serial number of one of the remote frames
  • C . Remote frame Link Module IPv6 address
  • D . Request code from the primary HPE Composer

Reveal Solution Hide Solution

Correct Answer: A
Question #3

How can your customer implement HPE OneView so that it can be used to manage an HPE ProLiant server and HPE BladeSystem?

  • A . As an application running on the server with Windows system.
  • B . As a physical appliance based on HPE ProLiant 360 Gen 10.
  • C . As an application running on the server with CentOS Linux system
  • D . As a virtual appliance running on the supported hypervisor.

Reveal Solution Hide Solution

Correct Answer: D
D

Explanation:

Reference: https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-c03934110

Question #4

DRAG DROP

For each feature. indicate whether it is available with both hpeoneview Standard and hpeoneview Advanced licenses, or only with an hpeoneview Advanced license.

Reveal Solution Hide Solution

Correct Answer:

Explanation:

Graphical user interface, application

Description automatically generated


Question #5

A customer has to deploy 21 HPE Synergy Compute Modules in a boot from SAN setup .

How this task can be simplified while keeping the profile consistent?

  • A . Boot volumes can be created on demand and defined in the server profile template.
  • B . Boot volumes can be prepared in advance and later presented as shared volumes to the Compute Modules.
  • C . An existing volume can be replicated automatically when creating a server profile.
  • D . single SAN volume can be created and utilized by all HPE Synergy Compute Modules.

Reveal Solution Hide Solution

Correct Answer: A
Question #6

You plan to update HPE OneVew to the latest version

What Should you do Mora starting HPE OneView update?

  • A . Disable HPE Remote Support at toe HPE OneView appliance level
  • B . Put all servers managed through HPE OneView to maintenance state
  • C . Run the Update Readiness checker tool to evaluate HPE OneView health status
  • D . Create a support dump for the appliance and for all managed logical interconnects

Reveal Solution Hide Solution

Correct Answer: C
Question #7

Your customer is considering HPE Synergy as a hardware platform for visualization workload. The customer environment is wry dynamic, and they often have to modify hypervisor networking.

Which resource provided by HPE should you discuss with this customer?

  • A . HPE OneView Global Dashboard allows server profile replication and change management.
  • B . PowerShell Library for HPE OneView allows scripted environment modification.
  • C . HPE OneView for VMware vCenter Server will enable host profile functionality and simplify changes.
  • D . HPE Image Streamer provides templates which can be updated to map the hypervisor
    requirements

Reveal Solution Hide Solution

Correct Answer: C
C

Explanation:

Reference: https://developer.hpe.com/blog/powershell-defined-infrastructure/

Question #8

What is the best practice when deploying an HPE OneView appliance?

  • A . Enable VMware Fault Tolerance if the appliance is deployed to a VMware hypervisor.
  • B . deploy the appliance in a hypervisor cluster that Is not managed by OneView.
  • C . Use thin-provisioning for the HPE OneView appliance to save storage capacity.
  • D . Deploy two HPE OneView appliances and configure them in HA mode.

Reveal Solution Hide Solution

Correct Answer: B
Question #9

Your customer wants to manage their HPE Superdome Flex using HPE OneView.

Which component must be added to HPE OneView to accomplish this task?

  • A . Baseboard Management Controller (BMC)
  • B . Rack Management Controller (RMC)
  • C . all nPARs created within the complex
  • D . only the base chassis from the complex

Reveal Solution Hide Solution

Correct Answer: B
B

Explanation:

Reference: http://itdoc.hitachi.co.jp/manuals/rv3000/hard/SDF/Server/SDF280/P06150-401a.pdf

Question #10

Refer to the exhibit.

After adding SAN Manager to HPE OneView. you noticed that all SANs are in the discovered state .

How will this affect HPE OneView storage management capabilities?

  • A . Snapshot functionality will be limited only to the volumes not using these SANs.
  • B . Volume presentation through server profile will work with the discovered state.
  • C . Auto-zoning functionality will not work until SANs are associated with networks.
  • D . Volume provisioning will only work for arrays that ate accessible through these SANs.

Reveal Solution Hide Solution

Correct Answer: C

Question #11

DRAG DROP

For HPE Primera, match each task with the management tool that can be used to perform it.

Reveal Solution Hide Solution

Correct Answer:

Explanation:

Graphical user interface, application

Description automatically generated


Question #12

Which components require an HPE OneView license for management?

  • A . HPE Virtual Connect modules
  • B . HPE Apollo XL 170r
  • C . Brocade and Cisco SAN Manager
  • D . HPE Primera and HPE 3PAR

Reveal Solution Hide Solution

Correct Answer: A
Question #13

Which statement regarding HPE OneView backup restore is true?

  • A . During backup restore, users with Administrator privileges can still login to HPE OneView
  • B . An HPE OneView backup can be used to restore individual components like server profile
  • C . Users with Backup Administrator privileges can restore an HPE OneView backup
  • D . Only users with Infrastructure Administrator privileges can restore an HPE OneView backup

Reveal Solution Hide Solution

Correct Answer: A
Question #14

HOTSPOT

Click the option that will prevent the appliance from sending any email notifications or forwarding any SNMP traps that are related to the server hardware.

Reveal Solution Hide Solution

Correct Answer:

Explanation:

Graphical user interface, application

Description automatically generated


Question #15

Your customer plans to use HPE OneView to manage a small environment based on HPE ProLiant servers that includes G7 and Gen 10 systems .

What should you explain to thiscustomer?

  • A . HPE Management Agent must he installed for HPE ProLiant Gen 10 servers.
  • B . HPE ProLiant G7 and Gen10 cannot be managed using the same appliance.
  • C . Not all of the features will be available for HPE ProLiant G7 systems.
  • D . HPE ProLiant Gen 10 servers do not need an HPE OneView license.

Reveal Solution Hide Solution

Correct Answer: C
C

Explanation:

Reference: https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&docId=emr_na-a00036908en_us

Question #16

Your customer wants to optimize GenlO servers for a virtualization workload by configuring all of them with a specific workload profile in the BIOS. All of the servers are managed using HPE OneView.

How can this task be completed?

  • A . Set a specific workload profile within Logical Interconnect Group and update all servers.
  • B . Set a specific workload profile for all managed servers as an HPE OneView global setting.
  • C . Set a specific workload profile within server profile template and update all profiles.
  • D . Set a specific workload profile using IL0 interface for each individual server.

Reveal Solution Hide Solution

Correct Answer: C
Question #17

Refer to the exhibit.

Which statement about the logical interconnect shown is true?

  • A . For FC uplink sets, an additional uplink from second module should be added for redundancy.
  • B . The maximum supported number of the internal networks for logical interconnect is configured.
  • C . Additional uplink ports can be added to ETH-Uplink to increase available bandwidth.
  • D . FC uplinks are not supported and will be converted to FCoE or RoCE uplinks.

Reveal Solution Hide Solution

Correct Answer: C
Question #18

Which licenses are optional to be purchased separately for HPE Synergy?

  • A . Global Dashboard licenses
  • B . FC Upgrade licenses
  • C . HPE OneView licenses
  • D . Virtual Connect licenses

Reveal Solution Hide Solution

Correct Answer: B
B

Explanation:

Licenses were not purchased in the original order for the modules and were ordered separately.

Reference: https://support.hpe.com/hpesc/public/docDisplay?docId=a00045233en_us&docLocale=en_ US

Question #19

Which statement about managing an HPE BiaoeSystem server is true?

  • A . A multi-enclosure Virtual Connect domain can be imported to HPE OneView without disrupting servers
  • B . Both c3000 and C7000 HPE BladeSystems enclosures can be imported to HPE OneView for monitoring
  • C . An HPE server blade cannot be deleted from HPE OneView It must be physically removed from the enclosure
  • D . An HPE server blade can be removed from HPE OneView by deleting the server from the Server Hardware section

Reveal Solution Hide Solution

Correct Answer: B
Question #20

Refer to the exhibit.

Your customer created multiple networks in HPE OneView, but only Eth-1 is available to be used within a server profile .

What is a likely cause of this situation?

  • A . The other networks are not configured with the required Smart Link parameter.
  • B . The other networks are not added to the Logical Interconnect Group configuration.
  • C . The other networks have Private Network’ selected, which hides them from ComputeModules.
  • D . The other networks are configured with a purpose other than General or Management.

Reveal Solution Hide Solution

Correct Answer: B

Question #21

What step must be taken to add an HPE SuperDome Flex to an existing OneView environment

  • A . A Rack Management Controller must be added to HPE OneView.
  • B . HPE Superdome Flex can be added to HPE OneView after at least one nPAR is created.
  • C . Each HPE Superdome Flex chassis must be added Individually using BMC IP.
  • D . HPE Superdome Flex complex can be added by adding base chassis of this complex.

Reveal Solution Hide Solution

Correct Answer: A
Question #22

How will setting the Purpose field within the network definition of a server profile impact the network traffic?

  • A . network purpose can give higher priority for a specific type of traffic
  • B . network purpose will impact the traffic only if Virtual Connect modules are used
  • C . network purpose will define QoS within Logical Interconnect
  • D . network purpose does not affect the behavior of the network

Reveal Solution Hide Solution

Correct Answer: D
Question #23

HOTSPOT

Click the option that will allow you to disable virtual MAC addresses or generate a new pool of virtual Worldwide Names.

Reveal Solution Hide Solution

Correct Answer:


Question #24

Which statement about an HPE OneView server profile is true?

  • A . A server profile can be created only for HPE BladeSystem, HPE Synergy, and HPE Superdome Flex servers.
  • B . A server profile created for a specific server hardware type cannot be moved to a server with a different server hardware type.
  • C . A server profile can be used to configure a local storage controller, but cannot be used to configure SAN-based storage.
  • D . A server profile can be used to update firmware and drivers when the operating system on the server is up and running.

Reveal Solution Hide Solution

Correct Answer: B
Question #25

You originally configured boot mode for HPE ProLiant Gen10 server to ‘Legacy BIOS’ in an HPE OneView server profile and deployed an operating system. A few weeks later, you change the boot mode to the ‘UEFI optimized’ to leverage some features provided by this mode.

What must you do next?

  • A . reset an il_0 management processor to activate the new boot mode for the server
  • B . reinstall an operating system, as UEFI is using different drive format than Legacy BIOS
  • C . reset BIOS settings to the defaults so UEFI settings can be applied
  • D . reset BIOS settings to the defaults through the server profile after changing the boot mode

Reveal Solution Hide Solution

Correct Answer: B
Question #26

HOTSPOT

Click the option that will allow you to update the firmware of master and satellite modules.

Reveal Solution Hide Solution

Correct Answer:


Question #27

Which action is allowed on storage pools managed by HPE OneView?

  • A . Volume provisioning
  • B . Setting storage pool replication
  • C . Changing storage pool RAID level
  • D . Changing storage pool capacity

Reveal Solution Hide Solution

Correct Answer: A
Question #28

HOTSPOT

As a part of troubleshooting, you have to reinstall the same version of the firmware on an HPE Synergy Compute Module. Click the area within the Firmware section of the server profile that will allow you to install the same firmware version.

Reveal Solution Hide Solution

Correct Answer:



Question #29

You want to update the firmware for only two HPE Synergy Virtual Connect SE 32Gb FC Modules of a large environment.

From which level must this procedure be initiated?

  • A . Logical Enclosure
  • B . Logical Interconnect Group
  • C . Logical Interconnect
  • D . Server Profile

Reveal Solution Hide Solution

Correct Answer: C
C

Explanation:

Reference: https://cdn.cnetcontent.com/syndication/feeds/hp-ent/inline-content/S7/C/D/CD7C939EFCECEA1124D03234E6E25BC684192820_source.PDF

Question #30

You are creating a Logical Interconnect Group for a three-frame HPE Synergy solution with HPE Virtual Connect SE100Gb F32 Modules for Synergy.

In which scenario should you set redundancy for master modules to be highly available?

  • A . When storm control or loop protection will be enabled for Virtual Connect modules
  • B . When each of the frames has two Virtual Connect modules installed
  • C . When each Virtual Connect module is installed in different frame
  • D . When each Virtual Connect module is installed in different fabric

Reveal Solution Hide Solution

Correct Answer: C

Question #31

Which statement about the volume template is true?

  • A . Users will be able to change sharing type and volume capacity
  • B . A volume created using this template will not support deduplication
  • C . A volume created using this template mil not support snapshots
  • D . Users will be able to select storage pool during volume creation

Reveal Solution Hide Solution

Correct Answer: D
Question #32

Which statement about HPE OneView Global Dashboard is true?

  • A . It is an application that can be installed on Windows or Linux system that will provide automated discovery of HPE OneView instances
  • B . It is a plugin to HPE Oneview that will allow integration of HPE oneView with VMware management and monitoring components
  • C . It is a virtual appliance that can aggregate health and inventory information from multiple HPE OneView appliances or HPE Composers
  • D . It is a plugin to vCenter Server that will allow management of the components added to HPE Oneview from vCenter server interface

Reveal Solution Hide Solution

Correct Answer: C
Question #33

Which statement about a Logical Enclosure for HPE BladeSystem is Hue?

  • A . A logical enclosure can have between 1 to 5 HPE BladeSystem c7000 enclosures.
  • B . A logical enclosure must be created only for monitored HPE BladeSystem C700O enclosures.
  • C . A logical enclosure is created automatically, and it is always based on a single enclosure.
  • D . A logical enclosure can contain a mix of HPE BladeSystem c7000 and C3000 enclosures.

Reveal Solution Hide Solution

Correct Answer: C
Question #34

Refer to the exhibit.

A customer complains that firmware compliance is empty. The customer confirmed that Synergy Service Pack is uploaded to the HPE OneView repository .

How should you respond?

  • A . The refresh procedure must be performed on each logical enclosure to refresh firmware.
  • B . All of the components are up to date and compliant with firmware baseline.
  • C . The firmware repository service must be restarted using maintenance connection.
  • D . The firmware repository is not defined within firmware compliance report.

Reveal Solution Hide Solution

Correct Answer: A
Question #35

Which statement about access to HPE Onboard Administrator is true when an HPE BladeSystem enclosure is added to HPE OneView?

  • A . It is blocked when an HPE BladeSystem enclosure is managed using HPE OneView.
  • B . It is enabled only when an HPE BladeSystem enclosure is monitored using HPE OneView.
  • C . It is enabled when an HPE BladeSystem is either managed or monitored using HPE OneView.
  • D . It is blocked when HPE BladeSystem enclosure is monitored using HPE OneView.

Reveal Solution Hide Solution

Correct Answer: A
Question #36

Your customer asks you if it is possible to perform HPE Synergy initial setup remotely .

How should you respond?

  • A . Remote HPE Synergy setup is possible if HPE Composer 2 is used and a DHCP server Is available in the management network.
  • B . Remote HPE Synergy Installation can be done only if an additional set of the services was purchased together with hardware platform.
  • C . HPE Synergy cannot be deployed remotely, as Initial setup must be performed using a local console connection.
  • D . HPE Synergy can be configured remotely through a secure connection to the FLM if this option was enabled In the factory.

Reveal Solution Hide Solution

Correct Answer: A
A

Explanation:

HPE Synergy 4-port Frame Link Modules have SFP+ ports which enable connections to distant frames and remote subnets.

Reference: https://cdn.cnetcontent.com/syndication/feeds/hp-ent/inline-content/S6/5/0/5029A837AB821E112E962CFFA2E59E065568F85E_source.PDF

Question #37

What event occurs on iLO when an HPE ProLiant server is added to HPE OneView?

  • A . IPMI credentials are configured for the iLO
  • B . REST API plugin is enabled for iLO
  • C . Active Directory configuration is performed on iLO
  • D . SSO certificate is added to the iLO

Reveal Solution Hide Solution

Correct Answer: D
Question #38

Which connection type can be defined within a server profile for an MPE ProLiant DL server?

  • A . iSCSI
  • B . RoCE
  • C . FC
  • D . Ethernet

Reveal Solution Hide Solution

Correct Answer: D
Question #39

HOTSPOT

You want a server profile to be automatically applied when an HPE Synergy Compute Module is replaced.

Click the appropriate configuration option.

Reveal Solution Hide Solution

Correct Answer: Affinity: Device bay + server hardware"
Question #40

Your customer added HPE Primera to HPE OneVlew and enabled volume provisioning on all storage pools. For security reasons, the customer wants to disable volume provisioning using HPE OneView on a specific storage pool.

How can this task be completed?

  • A . The storage pool should be removed from HPE OneView using a PowerShell script.
  • B . The storage pool should be disabled using the array management tool.
  • C . The storage pool state should be changed to discovered using HPE OneView.
  • D . The storage pool should be marked as read-only using HPE OneView.

Reveal Solution Hide Solution

Correct Answer: C

Question #41

You try to add a new connection within a server profile, but an operation fails when you try to commit the changes.

What is a possible reason?

  • A . You tried to add additional connection above the limit
  • B . The server is powered on
  • C . The server does not have an HPE OneView license applied
  • D . The server is powered off

Reveal Solution Hide Solution

Correct Answer: A
Question #42

HOTSPOT

You need to make sure that server ports connected to this network cannot communicate with each other within the logical interconnect. Click the option within the network definition that will allow you to configure the required parameter.

Reveal Solution Hide Solution

Correct Answer:



Question #43

Which statement about RoCE network restrictions is true?

  • A . RoCE networks require Virtual Connect SE 32Gb FC Modules.
  • B . RoCE networks cannot be configured when Virtual Connect modules are used.
  • C . RoCE networks are supported only when PVLANs are enabled.
  • D . RoCE networks are not supported with HPE BladeSystem

Reveal Solution Hide Solution

Correct Answer: D
Question #44

Where is the association between an HPE OneView network and uplink port defined?

  • A . Within an Enclosure Group definition
  • B . Within an HPE OneView network definition
  • C . At the network set level
  • D . At the Logical Interconnect Group level

Reveal Solution Hide Solution

Correct Answer: D
D

Explanation:

Reference: https://techlibrary.hpe.com/docs/synergy/Synergy_D3940/setup_install/238847.htm

Question #45

Which operation can be performed using HPE OneView for VMware vCenter Server?

  • A . Remove a new node from an existing cluster
  • B . Create a new VMware cluster within vCenter Server
  • C . Configure VMware cluster properties tor HA and DRS
  • D . Create a new distributed switch for cluster connectivity

Reveal Solution Hide Solution

Correct Answer: B
Question #46

You are deploying HPE OneView to manage a customer’s HPE ProLiant servers

Is this statement about appliance availability true?

  • A . HA features for HPE OneView are enabled only if the appliance is deployed on an HPE SimpliVity cluster
  • B . HPE OneView has a built-in HA feature that can be activated with an additional license
  • C . HPE OneView availability relies on HA features provoed by the hypervisor
  • D . During hpeoneView deployment customer may select configure proprietary HA mode.

Reveal Solution Hide Solution

Correct Answer: C
Question #47

Your customer has an environment with five HPE Synergy Composers and 15 HPE OneView appliances managing servers that run VMware. The customer is having a hard time managing their servers.

What can the customer do to simplify management of this complex environment?

  • A . deploy HPE OneView for VMware vCenter Server
  • B . deploy HPE OneView Global Dashboard
  • C . use an Ansible playbook
  • D . integrate all HPE OneView appliances and HPE Composers with Active Directory

Reveal Solution Hide Solution

Correct Answer: B
B

Explanation:

Reference: https://cdn.cnetcontent.com/syndication/feeds/hp-ent/inline-content/S6/4/B/4B8377D8B6513D42276243DE3FE6597935C4DBEF_source.PDF

Question #48

Your customer plans to monitor HPE ProLiant DL systems and HPE BladeSystem using HPE OneView Which license is required to accomplish this task?

  • A . HPE One View Global Dashboard license
  • B . HPE OneView Advanced license
  • C . HPE composer 2 license
  • D . HPE OneView standard license

Reveal Solution Hide Solution

Correct Answer: D
Question #49

Refer to the exhibit.

Your customer wants to define a Logical Interconnect Group (UG) and set the redundancy of the master modules to highly available, but this option is not available .

What is a possible reason?

  • A . There are not sufficient frames for highly available setup.
  • B . Some master modules only support a redundant setup.
  • C . Firmware on the master modules is too low to support highly available setup.
  • D . A dedicated license must be added to HPE OneView to enable this feature.

Reveal Solution Hide Solution

Correct Answer: B
Question #50

HOTSPOT

Click option that will allow you to select a FlexNIC function for the specified connection.

Reveal Solution Hide Solution

Correct Answer:

Explanation:

Graphical user interface

Description automatically generated


Exit mobile version