HP HPE0-S60 Delta – HPE Compute Solutions Online Training
HP HPE0-S60 Online Training
The questions for HPE0-S60 were last updated at Dec 24,2024.
- Exam Code: HPE0-S60
- Exam Name: Delta - HPE Compute Solutions
- Certification Provider: HP
- Latest update: Dec 24,2024
Which compute node parameters are captured within server hardware type?
- A . Number of the CPUs
- B . installed operating system
- C . Mezzanine card configuration
- D . Size of the memory Installed
DRAG DROP
You need to setup HPE Synergy frames after hardware components are discovered within HPE OneView.
Put the steps to achieve this goal into the coned order in the answer area on the right.
Which statement about manual orchestration during the firmware update is true?
- A . It is supported only for logical enclosures with at least three frames
- B . It provides an ability to select and update one side of the Interconnect topology at a time
- C . It provides the ability to install an older firmware version than currently Installed In the interconnect
- D . It allows all the interconnect modules to be activated manually at the same time.
Which statement about the HPE D3940 storage module is true?
- A . SATA drives requires redundant 10 adapters to be installed in this module
- B . Up to five modules can be installed in a single frame with Gen10 servers
- C . it is configured through CLl available from HPE Synergy console
- D . Only one type of drives (SATA, SAS, SSD) can be installed in each module
Your customer has 6 logical enclosures spanning 18 HPE Synergy frames. The customer needs to add one more logical enclosure based on 5 HPE Synergy frames
How will this change impact the customer environment?
- A . The customer can add a new logical enclosure to the existing setup because the maximum number of logical enclosures in a single management ring is not reached.
- B . The customer has to expand the management ring capacity either by adding HPE Composer 2 modules or adding memory to reach 128GB per module.
- C . The customer has to create a new management ring for new logical enclosure because the maximum number of frames m a single management ring is reached.
- D . The customer can add a new logical enclosure to an existing setup once all required licenses are added lo HPE OneView and associated with the new frames.
Your customer plans to deploy VMware vSAN using D3940 Storage Modules.
Which statement about this solution is true?
- A . The 12Gb SAS modules required for D3940 connectivity can only be installed in the first fabric.
- B . To use the storage controller that will access D3940 storage modules, a second CPU must be installed.
- C . For VMware vSAN deployment, all drives in the D3940 storage modules must be SSD drives.
- D . All drives in the D3940 storage modules must formulate a single logical drive with RAID5 configured
Your customer wants to add dedicated Fibre Channel connectivity to the HPE Synergy frame running HPE Synergy 480 Gen10 compute modules, each with one CPU socket populated Currently they use two 12 Gb SAS switches and two HPE Virtual Connect SE 100Gb F32 Modules for HPE Synergy installed in third fabric.
What must be done to enable dedicated FC connectivity for this HPE Synergy frame?
- A . A second CPU must be installed for all HPE Synergy 480 Gen10 compute nodes.
- B . For Brocade switches, a logical interconnect group must be created in HPE OneView.
- C . For VC-FC modules, all of server facing ports must be property licensed.
- D . SAS switches must be moved to second fabric and FC modules Installed in the first one.
You are troubleshooting an HPE OneView server profile that presents a critical state. The server profile was configured with a Link Aggregation Group
What should you check to fix the issue?
- A . if both FiexNICs are configured with the same speed
- B . If the logical enclosure is built on at least three HPE Synergy frames
- C . if both FiexNICs are connected to different networks
- D . if the logical enclosure is configured with redundant master modules
Your customer plans to expand an existing nPar based on a single HPE Superdome Flex chassis.
Which statement about workload availability during expansion is true?
- A . Powered nPar can be expanded only if HPE Superdome Flex 280 is used
- B . Online expansion is available only if RMC is used for management.
- C . HPE Superdome Flex does not support expansion of powered on nPars
- D . Powered nPar can be expanded if it does not use HPE Persistent Memory
Which tool can be used to evaluate me health of an HPE Oneview appliance before proceeding with an appliance updated.
- A . HPE Composer Maintenance Console
- B . HPE OneView Update Readiness Checker
- C . HPE OneView Global Dashboard
- D . HPE OneView Firmware Compliance Report