You have a two-node NetApp clustered Data ONTAP storage system, a Cisco UCS system with two Fabric Interconnects, and a dual-fabric (Fabric-A and Fabric-B) Fibre Channel topology with the information shown below.
– Node 01 has one 10Gb FCoE connection to Fabric-A and one 10Gb FCoE connection to Fabric-B.
– Node 02 has one 10Gb FCoE connection to Fabric-A and one 10Gb FCoE connection to Fabric-B.
– Fabric Interconnect A has a two-port FCoE port channel to Fabric-A
– Fabric Interconnect B has a two-port FCoE port channel to Fabric-B.
– Each IOM in the Cisco UCS blade chassis has four uplinks into the Fabric Interconnects.
– A service profile running VMware ESXi has one vHBA in Fabric-A and one vHBA in Fabric-B.
How many paths should ESXi see to its FC boot LUN?
A . 2
B . 4
C . 6
D . 8
Answer: C
Latest NS0-176 Dumps Valid Version with 145 Q&As
Latest And Valid Q&A | Instant Download | Once Fail, Full Refund