What can we learn from the above information?

The customer's two switches SWA and SWB are connected together through seven Ethernet cables and configured with dynamic link aggregation . The corresponding ports on switch SWA are Ethernet 1/0 Ethernet 1/0/2 , Ethernet 1/0/3 , Ethernet 1/0/4 , Ethernet 1/0/5 , Ethernet 1/0/6 , Ethernet1/0/7 If switches SWA and...

September 28, 2024No CommentsREAD MORE +

If the interconnection interfaces of switches SWA, SWB, and SWC allow all VLANs to pass, what can we learn from the above information?

The customer's LAN switch SWA is connected to SWB via GigabitEthernet 2/0/1 and to SWC via GigabitEthernet 2/0/2 and the SWA switch has the following configuration: [SWA] smart-link group 1 [SWA-smlk-group1] protected-vlan reference-instance 0 to 32 [SWA-smlk-group1] port gigabitethernet 2/0/1 slave [SWA-smlk-group1] port gigabitethernet 2/0/2 master [SWA-smlk-group1] flush enable control-vlan...

September 28, 2024No CommentsREAD MORE +

Which of the following statements is correct?

In a certain network, it is planned to use an S3610 switch as a RADIUS client and two IMC servers as RADIUS servers to complete user security authentication access. Which of the following statements is correct?  A . When configuring the S3610, the RADIUS server type that should be selected...

September 27, 2024No CommentsREAD MORE +

In the network shown in the figure, the corresponding configuration is completed on the switch SWA, and the switch SWA and each PC have learned the corresponding ARPPCA. When accessing PCB, ICMP request message is sent, and the destination MAC address of the message is?

In the network shown in the figure, the corresponding configuration is completed on the switch SWA, and the switch SWA and each PC have learned the corresponding ARPPCA. When accessing PCB, ICMP request message is sent, and the destination MAC address of the message is? A. FFFF.FFFF.FFFF B. MAC-10 C....

September 27, 2024No CommentsREAD MORE +

If you want to configure link aggregation to aggregate these two links, if the configuration on SWB is correct, which of the following you can know from the above information?

Switches SWA and SWB are connected together through two optical fiber Gigabit Ethernet links, and the following interface configuration is available on switch SWA: [SWA] interface GigabitEthernet 1/0/1 [SWA-GigabitEthernet1/0/1] gvrp [SWA-GigabitEthernet1/0/1] port link-type trunk [SWA-GigabitEthernet1/0/1] port trunk permit vlan 1 10 [SWA] interface GigabitEthernet 1/0/2 [SWA-GigabitEthernet1/0/2] port link-type trunk [SWA-GigabitEthernet1/0/2]...

September 27, 2024No CommentsREAD MORE +

Which of the following descriptions about H3C switch static routing is correct?

Which of the following descriptions about H3C switch static routing is correct?A . Layer 2 switches do not support routing forwarding, so static routing cannot be configured on Layer 2 switches.B . Layer 2 switches can be configured with static routingC . Only Layer 3 switches can be configured with...

September 26, 2024No CommentsREAD MORE +

As shown in the title figure, SWA, SWB, SWC and SWD have STP enabled. SWA, SWB and SWC form a loop. After the topology is stable, SWD and SWB are connected. Assuming that the cost of each link is the same, which of the following statements about the topology change process of STP are correct?

As shown in the title figure, SWA, SWB, SWC and SWD have STP enabled. SWA, SWB and SWC form a loop. After the topology is stable, SWD and SWB are connected. Assuming that the cost of each link is the same, which of the following statements about the topology change...

September 26, 2024No CommentsREAD MORE +

The customer's LAN switch SWA is dual-uplinked to switch SWB and switch SWC, and link reliability is guaranteed by Smart Link. If the MAC address of switch SWA is 000f-e269-42d1, the MAC address of switch SWB is 000f-e269-42d2, and the MAC address of switch SWC is 000f-e269-42d3, what can we learn from the above information?

The customer's LAN switch SWA is dual-uplinked to switch SWB and switch SWC, and link reliability is guaranteed by Smart Link. If the MAC address of switch SWA is 000f-e269-42d1, the MAC address of switch SWB is 000f-e269-42d2, and the MAC address of switch SWC is 000f-e269-42d3, what can we...

September 25, 2024No CommentsREAD MORE +

After executing the display interface Ethernet 1/0/1 command on the switch SWA, the output information is as follows: From the above output, what can be inferred from the above output?

After executing the display interface Ethernet 1/0/1 command on the switch SWA, the output information is as follows: From the above output, what can be inferred from the above output? [SWA] display interface Ethernet 1/0/2 Ethernet1/0/2 current state: UP …………. PVID: 10 Mdi type: auto Link delay is 0 (sec)...

September 25, 2024No CommentsREAD MORE +