What must the engineer do to control the first blade with a connected monitor, keyboard, and mouse?
An engineer has connected a monitor, keyboard, and mouse to a VRTX chassis. The engineer is unable to see or control the first blade. What must the engineer do to control the first blade with a connected monitor, keyboard, and mouse?A . Map the KVM to the first blade in...
What is causing this issue?
An engineer is updating the IOM Infrastructure Device firmware from the CMC GUI. The IOMINF device is NOT listed as a device that can be updated. What is causing this issue?A . IOMINF firmware is up to date.B . IOMINF firmware can NOT be updated from CMD . The update...
Which step should the engineer take to perform this task?
An engineer needs to limit the power consumption of a chassis without powering down any server nodes. Which step should the engineer take to perform this task?A . Use the CMC to configure the System Input Power Cap for the chassisB . Use the iDRAC to configure the Power Cap...
What additional software should the engineer install?
An engineer needs to enable automated proactive support from Dell for ProSupport entitled assets discovered in OpenManage Essentials. What additional software should the engineer install?A . Dell ProSupport for ServersB . Dell SupportAssist for ServersC . Dell Phone Home for OpenManage EssentialsD . Dell SupportAssist for OpenManage EssentialsView AnswerAnswer: D
How can the engineer exclude a firmware update while still using the Dell Online Catalog source?
An engineer is performing system updates on a large number of systems using OpenManage Essentials. The engineer has been instructed NOT to update network adapter firmware at this time. How can the engineer exclude a firmware update while still using the Dell Online Catalog source?A . Delete the firmware update...
Which two steps are required to complete this task?
An engineer needs to assign two PCIe NICs and a GPU to a server node in a VRTX chassis. Which two steps are required to complete this task? (Choose two. )A . Enable PCIe Ride-throughB . Upgrade the CMC licenseC . Power off the nodeD . Update all firmwareView AnswerAnswer:...
What is the most cost effective way to update firmware in each location?
Company servers are in the branch offices located at different geographic locations. All servers are running ESXi hypervisor. The are no network connections between the branch office and central office. What is the most cost effective way to update firmware in each location?A . Send a server administrator on site...
How should the engineer perform this task?
An engineer needs to perform hardware configuration, including RAID, on a new batch of 30 identical server nodes. OpenManage Essentials is installed, and the sever nodes have been discovered via iDRAC. The engineer needs the most efficient way to replicate the configuration from a single configured system without losing connectivity...
What additional configuration needs to be done to be informed via email of the detailed server failure?
An engineer configures an Alert Action in the CMC to send an email on Warning and Critical events. Chassis fan and power events are showing up as expected. Server-specific failures such as memory module failures only indicate that the server has gone into a Critical or Warning state. What additional...
Which step should the engineer take to perform this task?
An engineer needs to limit the power consumption of a chassis without powering down any server nodes. Which step should the engineer take to perform this task?A . Use the CMC to configure the System Input Power Cap for the chassisB . Use the iDRAC to configure the Power Cap...