Which two tasks should the engineer perform to improve OME performance and scalability?
An engineer needs to use OME to monitor 4000 servers in the environment. Which two tasks should the engineer perform to improve OME performance and scalability? (Choose two. )A . Increase OME discovery/inventory frequencyB . Install OME on a physical serverC . Install OME in a virtual serverD . Use...
What should be done to restore administrative access to the CMC?
A password to the CMC root account on an M1000e server chassis has been misplaced. What should be done to restore administrative access to the CMC?A . Reset root password using the PASSWORD_RSET jumperB . Issue password reset from a connected blade’s iDRACC . Call Dell tech support and ask...
What two tasks should be completed to troubleshoot this issue?
A new M1000e is being deployed in the data center. All initial power and data cabling is complete. The engineer checks the CMC Chassis Health and sees that one of the six PSUs displays as Failed (No AC). An AC cable is connected, and the power distribution unit produces good...
What is the cause?
An engineer is running an inventory report on a VRTX chassis group for a customer. When the engineer views the report, the engineer notices the inventory of one of the VRTX is missing one of its nodes. What is the cause?A . The VRTX group member is in Chassis Power...
Which cables does the engineer need for this module?
Refer to the exhibit. An engineer receives a pair of the modules shown to install in a pair of MXL switches. Which cables does the engineer need for this module?A . OM4 MTP Crossover Fiber Cable (optics required)B . SFP+ to SFP+, 10GbE, Copper Twinax Direct AttachC . QSFP+ to...
What is the most effective update strategy?
An engineer needs to update BIOS in the following environment: - Over 100 servers are spread over 10 chassis - All servers are in the same data center - The only maintenance window is late Sunday evening when OS patches are applied and servers are rebooted - Less than 10...
What is the cause of this issue?
A VRTX server comes with two server modules. The customer requests to assign three PCIe Adapters per each server module. While performing this configuration, the engineer is unable to assign more than two PCIe Adapters per server module. What is the cause of this issue?A . The VRTX chassis came...
What is causing this message?
An engineer is installing a server node with a quad port 1GbE NIC into SLOT 3 on a VRTX chassis with a 1GbE Pass-Through Module (PTM) in Fabric A. During POST of this server, a message indicates that ports 3 and 4 of the NIC are being disabled. The system...
After downloading and installing Dell OpenManage Essentials with SupportAssist, which two steps must be done to complete this task?
An engineer is deploying Dell SupportAssist to manage a data center. After downloading and installing Dell OpenManage Essentials with SupportAssist, which two steps must be done to complete this task? (Choose two. )A . Run DSET script to collect Dell SupportAssist reports for each server.B . Make sure the OME...
Which option should be used to integrate Dell Server hardware into this monitoring architecture?
An engineer responsible for server lifecycle management (e. g. Monitor, Update, Deploy) needs to build a monitoring strategy for a multi-vendor data center. The company has an established third party software as the monitoring and help desk system. Which option should be used to integrate Dell Server hardware into this...