Beginning with VxRail version 4.7, which product license option has changed?
Beginning with VxRail version 4.7, which product license option has changed?A . VSANB . vCenterC . VMware Log InsightD . vSphereView AnswerAnswer: A
How much space needs to be available to rack all the VxRail nodes?
A VxRail Moel E560 Cluster will be deployed in a 1 GbE network. The system is delivered in its largest supported configuration. How much space needs to be available to rack all the VxRail nodes?A . 4UB . 8UC . 16UD . 64UView AnswerAnswer: B
What components of a VxRail node must be assigned IP addresses?
What components of a VxRail node must be assigned IP addresses?A . ESXi host. Center. ESRB . and iDRACC . ESXi host, vSAD . Center. and ESRSE . ESXi host, vSAF . vMouon. and iDRACG . vSAH . Center. vRealize Log Insight. and vMotionView AnswerAnswer: C
What command is used to restart the Loudmouth process on a VxRail node?
What command is used to restart the Loudmouth process on a VxRail node?A . /usr/lib/vmware/loudmouth/bin/loudmouth restartB . systemctl restart loudmouthC . systemctl restart vmware-loudmouthD . /etc/init.d/loudmouth restartView AnswerAnswer: A
What is the minimum node configuration?
A VxRail Stretched Cluster deployment will have E560F nodes. The Cluster must allow local protection with both erasure coding options at either site. What is the minimum node configuration?A . 3+3 nodesB . 4+4 nodesC . 6+6 nodesD . 8+8 nodesView AnswerAnswer: B
What is the minimum number of VxRail nodes required for a SAN storage policy with FTT = 2 and FTM set to Erasure Coding?
What is the minimum number of VxRail nodes required for a SAN storage policy with FTT = 2 and FTM set to Erasure Coding?A . 4B . 5C . 6D . 7View AnswerAnswer: C
What is the purpose of the PTAgent on a PowerEdge-based VxRail node?
What is the purpose of the PTAgent on a PowerEdge-based VxRail node?A . Hardware monitoring, SATADOM updating and firmware installationB . Hardware discovery, hardware monitoring, and VxRail VIB installationC . Hardware monitoring, SATADOM updating, and VxRail node electionD . Hardware discovery, hardware monitoring, and firmware installationView AnswerAnswer: D
Which requirement must be met when expanding a VxRail G560F 3 node Cluster with a 4th G Series node in the same chassis?
Which requirement must be met when expanding a VxRail G560F 3 node Cluster with a 4th G Series node in the same chassis?A . Node must be a hybrid nodeB . Node requires only the same processor typeC . Node requires only the same drive configurationD . Node must be...
What is the correct order of steps to finish the upgrade?
You have determined that you need to execute a RASR factory upgrade of a VxRail v4.7.1xx node. You download the RASR ISO from the Dell Support site. What is the correct order of steps to finish the upgrade? View AnswerAnswer:
What is the maximum number of separate vCenter instances that an OMNI plug-in can be registered with in a single fabric?
You are configuring SmartFabric Services on a VxRail running version 4.7.x. What is the maximum number of separate vCenter instances that an OMNI plug-in can be registered with in a single fabric?A . 1B . 2C . 5D . 10View AnswerAnswer: D