Which host OS supports both 512 bytes and 4 KB XtremIO logical block (LB) volumns?

Which host OS supports both 512 bytes and 4 KB XtremIO logical block (LB) volumns?A . VMwareB . LinuxC . IBM AIXD . HP-UXView AnswerAnswer: B

September 17, 2024No CommentsREAD MORE +

What is true about the flow control feature when configuring he iSCSI SAN from the host to the XtremIO cluster?

What is true about the flow control feature when configuring he iSCSI SAN from the host to the XtremIO cluster?A . Disable flow control features on the server, switch(s) and array portsB . Enable flow control features on the server and array port onlyC . Enable flow control features on...

September 16, 2024No CommentsREAD MORE +

What is the block size an XtremIO X2 uses to Optimize I/O handling internally?

What is the block size an XtremIO X2 uses to Optimize I/O handling internally?A . 16 kBB . 32 kBC . 64 kBD . 1024 kBView AnswerAnswer: A

September 12, 2024No CommentsREAD MORE +

At which point is data compressed when a host sends data to the XtremIO Storage system?

At which point is data compressed when a host sends data to the XtremIO Storage system?A . Inline before data is written to the SSDB . Once data is written to the Storage ControllerC . After data is written to the SSDsD . After data is in SSD cacheView AnswerAnswer:...

September 9, 2024No CommentsREAD MORE +

Which port of each storage controller shown in the exhibit should be used?

A customer wants to connect their Storage Controller to Fiber Channel switches using as many Fiber Channel port as possible. Which port of each storage controller shown in the exhibit should be used?A . 1 and 2B . 1,2,3 and 4C . 2 and 3D . 3 and 4View AnswerAnswer:...

September 7, 2024No CommentsREAD MORE +

Which I/O elevator setting should be selected for use with XtremIO?

Which I/O elevator setting should be selected for use with XtremIO?A . CfqB . DeadlineC . NoopD . AnticipatoryView AnswerAnswer: C

September 6, 2024No CommentsREAD MORE +

What is the recommended execution throttle setting for Windows, Linux, and VMware for Qlogic Adapter?

What is the recommended execution throttle setting for Windows, Linux, and VMware for Qlogic Adapter?A . 32B . 1024C . 16384D . 65536View AnswerAnswer: C

September 3, 2024No CommentsREAD MORE +

What should be the LUN queue depth setting per path?

A customer’s environment is configured as follows . Dual X-Brick cluster . 8 ESXi hosts with 2 Emulex HBAs . Each ESXi hosts has 8 LUNs . Each LUN is visible through 4 paths What should be the LUN queue depth setting per path?A . 64B . 128C . 256D...

September 2, 2024No CommentsREAD MORE +

Which DellEMC technology should recommended to the customer to meet these requirements?

A customer what you to design an XtremIO solution for an Oracle RAC application environment. The customer maintains two data centers and requires replication to a third site for disaster recovery purposes. The solution must be fault tolerant and capable of remaining online during planed and unplanned downtime event due...

August 31, 2024No CommentsREAD MORE +

Which Multipathing software is supported by ExtremIO?

Which Multipathing software is supported by ExtremIO?A . PowerPatch/VE and NMP on ESXi HostB . MPIO on non-clustered Microsoft Windows Hosts onlyC . PowerPath/VE on Microsoft Windows VMs hosted by ESXiD . Native MPIO on IBM AIX clustersView AnswerAnswer: C

August 30, 2024No CommentsREAD MORE +