When using VxRail Manager, what is the source of information that can help validate good VxRail system post-deployment status?

When using VxRail Manager, what is the source of information that can help validate good VxRail system post-deployment status?A . Last Heartbeat, Last Configuration Sent, Network Environment Settings, Cluster MonitorB . System Diagnostic, Events, Health Logical View, Health Physical View, Log BundleC . MARVIN-Virtual-SAN-Cluster > Manage > Health and PerformanceD...

March 8, 2024 No Comments READ MORE +

Which VxRail node type support only hybrid storage?

Which VxRail node type support only hybrid storage?A . S SeriesB . E SeriesC . G SeriesD . V SeriesView AnswerAnswer: A

March 8, 2024 No Comments READ MORE +

Where is the VxRail Manager pre-installed on a newly shipped, 4 node VxRail Model G410 system?

Where is the VxRail Manager pre-installed on a newly shipped, 4 node VxRail Model G410 system?A . Node with the highest serial numberB . Bottom-right node from the frontC . All nodesD . First nodeView AnswerAnswer: D

March 8, 2024 No Comments READ MORE +

What is the recommended way to power up VxRail E, V, P, and S Series nodes?

What is the recommended way to power up VxRail E, V, P, and S Series nodes?A . Ensure the System Health indicator blinks amber for 10 minutes after power onB . Use the power button on the rear panel to power on each nodeC . Wait at least 30 seconds...

March 8, 2024 No Comments READ MORE +

What is the Dell EMC recommendation for VxRail Management VLANs?

What is the Dell EMC recommendation for VxRail Management VLANs?A . Use untagged traffic on the Native VLAN for the Public Management networkB . Use tagged traffic on the Native VLAN for the Public Management networkC . Configure the VLAN ID with a default of 3940D . Configure the VLAN...

March 8, 2024 No Comments READ MORE +

What could be the cause of this issue?

During a node add procedure the new node cannot be discovered. A ping to the IPv6 address is responding. What could be the cause of this issue?A . Only one network interface is up on the new nodeB . vSAN VLAN is not configured correctlyC . Management VLAN ID is...

March 8, 2024 No Comments READ MORE +

Which license is required for vSAN Data-At-Rest Encryption, and what is characteristic of this type of encryption?

Which license is required for vSAN Data-At-Rest Encryption, and what is characteristic of this type of encryption?A . Requires vSAN Enterprise Plus Applies to the entire datastoreB . Requires vSAN Standard Applies on a per VM basisC . Requires vSAN Advanced Applies on a per VM basisD . Requires vSAN...

March 8, 2024 No Comments READ MORE +

What should the administrator do to address this issue?

A system administrator attempts to use the VxRail REST API to obtain system health status for their VxRail environment. The system returns the following error code: 401. What should the administrator do to address this issue?A . Provide vCenter credentials with sufficient rightsB . Ensure that the VxRail Manager IP...

March 8, 2024 No Comments READ MORE +

Which command should they use?

A system administrator wants to collect a generated log file via the VxRail REST API. Which command should they use?A . POST /v1/support/logs/B . GET /v1/support/logs/<Log_ID>/downloadC . GET /v1/support/logs/<Log_ID>D . POST /v1/support/logs/<Log_ID>/downloadView AnswerAnswer: B

March 8, 2024 No Comments READ MORE +

What is validated by running the Proactive VM Creation test in vCenter on a VxRail cluster?

What is validated by running the Proactive VM Creation test in vCenter on a VxRail cluster?A . vSAN operates successfullyB . Network firewalls are configured correctlyC . vSAN has sufficient storage capacityD . Network performance is sufficientView AnswerAnswer: A