- All Exams Instant Download
What does this indicate?
Refer to the exhibit. A Storage Administrator noticed a drive LED blinking blue. What does this indicate?A . Is faultedB . Access activityC . Power upD . Identification is onView AnswerAnswer: B
How can the PUHC health check results be viewed?
How can the PUHC health check results be viewed?A . By accessing the Swagger UIB . From syslog serverC . In Details of Appliances and NodesD . From management DBView AnswerAnswer: A
What does the output of the PSTCLI command “nas_server show” display from a Dell EMC PowerStore T?
What does the output of the PSTCLI command “nas_server show” display from a Dell EMC PowerStore T?A . If NAS servers are present if they are either NFS or LicensedB . Memory utilization and thread count for NFS NAS serversC . If NAS servers are present and if they are...
Which component is only replaceable by qualified personnel?
Which component is only replaceable by qualified personnel?A . Battery backup unitB . Embedded I/O moduleC . Memory moduleD . 4-Port mezzanine cardView AnswerAnswer: C
Which component is an FRU?
Which component is an FRU?A . DIMMsB . Embedded IO ModuleC . NodesD . Battery Backup UnitView AnswerAnswer: A
Which NDU software upgrade option is used for this situation?
A Storage Administrator needs to address specific fixes within their Dell EMC PowerStore system. Which NDU software upgrade option is used for this situation?A . HotfixesB . vCenterC . Drive firmwareD . Software releasesView AnswerAnswer: A
Which drive configuration maximizes the base enclosure capacity?
A Storage Administrator needs to add drives to a base enclosure of a Dell EMC PowerStore 7000T system. The system currently contains 10 750 GB NVMe SCM drives. Which drive configuration maximizes the base enclosure capacity?A . 11 15360 GB NVMe SSD drives in slots 10 - 20B . 13...
Match the base enclosure SAS ports in column A to their corresponding expansion LCC ports in column B; when connecting a PowerStore base enclosure to a single expansion enclosure
DRAG DROP Match the base enclosure SAS ports in column A to their corresponding expansion LCC ports in column B; when connecting a PowerStore base enclosure to a single expansion enclosure. View AnswerAnswer:
What describes the system behavior in this circumstance?
A Storage Administrator notices two fans in a Dell EMC PowerStore are faulted. What describes the system behavior in this circumstance?A . A five-minute timer starts upon the second fan fault and the system shuts down automatically after the timer expiresB . CPU clock speed is reduced by 50% to...
What method is used to power down a Dell EMC PowerStore system in a true emergency situation?
What method is used to power down a Dell EMC PowerStore system in a true emergency situation?A . Run svc_node shutdownB . Power Down Cluster in PowerStore GUIC . Turn off the cabinet switchesD . Remove base enclosure power cablesView AnswerAnswer: C Explanation: Reference: https://www.dell.com/support/manuals/pk/en/pkbsd1/powerstore-1000/pwrstr-isg/power-control-procedure-considerations?guid=guid-4352c94e-0ae7-4a2e-8593-9ae135bb9e34&lang=en-us