What is the isi diagnostics gather command used for?
What is the isi diagnostics gather command used for?A . Diagnose the CPU.B . Diagnose the TPMC . Gather performance data.D . Gather cluster logsView AnswerAnswer: D Explanation: The isi diagnostics gather command is used in Dell PowerScale (formerly known as Isilon) clusters to collect comprehensive diagnostic information, including system...
Which rack should they use for the A3000 nodes?
A platform engineer must install several Dell PowerScale clusters. Which rack should they use for the A3000 nodes?A . Titan-HDB . Titan-DC . Titan-PView AnswerAnswer: A Explanation: For installing Dell PowerScale A3000 nodes, the appropriate rack to use is the Titan-HD (High Density) rack. The Titan-HD rack is specifically designed...
Which port slot provides management functionality on a PowerScale F600?
Which port slot provides management functionality on a PowerScale F600?A . PCle slot 3B . PCle slot 1C . rNDCstotD . PCle slot 2View AnswerAnswer: C Explanation: On a Dell PowerScale F600 node, the rNDC slot (redundant Network Daughter Card slot) provides management functionality. The rNDC slot hosts the network...
What does a terracotta colored handle indicate on Dell PowerScale Gen6 hardware?
What does a terracotta colored handle indicate on Dell PowerScale Gen6 hardware?A . The FRU must be replaced.B . The node can remain online when replacing a hardware component.C . The node must be shut down for maintenance procedures.D . The component must not be removed while hardware is online.View...
What connection test identifies the problem?
Windows clients cannot connect using the fully qualified domain name when testing the connectivity of a newly created cluster. What connection test identifies the problem?A . DNSB . NFS MountC . Mapping a Windows driveD . WebUI using IP addressView AnswerAnswer: A Explanation: When Windows clients cannot connect to a...
What status is an engineer trying to test if they run the isi_hwmon -s command?
What status is an engineer trying to test if they run the isi_hwmon -s command? A. DIMM B. Sensor C. CPU D. Battery E. SystemView AnswerAnswer: B Explanation: The command isi_hwmon -s is used on Dell PowerScale systems to display the status of various hardware sensors within a node. This...
A customer is planning to expand a Dell PowerScale Gen5 cluster with H500 nodes What is a consideration?
A customer is planning to expand a Dell PowerScale Gen5 cluster with H500 nodes What is a consideration?A . A minimum of three H500 chassis are needed.B . All new nodes must be on the network.C . A minimum of four H500 nodes are needed.D . A minimum of one...
What must the engineer do after powering off the nodes?
A platform engineer must replace a failed chassis on a Dell PowerScale Gen6 cluster. What must the engineer do after powering off the nodes?A . Remove the drive sleds, label them for identification, and place the drive sleds In the newly installed chassis.B . Remove the drive sleds and motherboard...
What are they attempting to do?
An engineer runs ini_reformat_node command. What are they attempting to do?A . Reformat the mirrored FEC data.B . Reformat a node quickly to repurpose a node.C . Reformat the mirrored journals.D . Reformat a node to securely erase all data.View AnswerAnswer: D Explanation: The isi_reformat_node command is a utility used...
What type of drive should a customer use to ensure that their data is encrypted?
What type of drive should a customer use to ensure that their data is encrypted? A. NVMe B. SSD C. SED D. Hard driveView AnswerAnswer: C Explanation: To ensure that their data is encrypted, a customer should use Self-Encrypting Drives (SEDs). SEDs provide hardware-based encryption, securing data at rest without...