What is a consideration when sizing?

You are sizing a PowerScale Gen6 cluster for a small organization that is concerned about the availability of the journal during an extended power outage. What is a consideration when sizing?A . Journal must be protected by an external UPS.B . Journal is written to nonvolatile storage if power is...

January 26, 2024 No Comments READ MORE +

What would be a good prequalifying question to ask?

You meet a customer for the first time. They explain that their current environment for NAS does not meet their needs. You want to make sure that Isilon is a good fit for their needs. What would be a good prequalifying question to ask?A . What Applications access this storage?B...

January 26, 2024 No Comments READ MORE +

What is the sector size of an Isilon 8 TB drive?

What is the sector size of an Isilon 8 TB drive?A . 1024 bytesB . 2048 bytesC . 4096 bytesD . 512 bytesView AnswerAnswer: C

January 26, 2024 No Comments READ MORE +

A large hospital organization is looking for a vendor neutral archive solution for their imaging data. When proposing an Isilon solution, which benefits should be discussed?

A large hospital organization is looking for a vendor neutral archive solution for their imaging data. When proposing an Isilon solution, which benefits should be discussed?A . Consolidation of imaging applications and ability to switch PACS systemsB . Deduplication of image data and Data at Rest EncryptionC . Data at...

January 26, 2024 No Comments READ MORE +

What is an accurate statement concerning shared journals on node pairs?

What is an accurate statement concerning shared journals on node pairs?A . Requires a minimum of 4 nodesB . Directly linked through mid-plane of the chassisC . When a node boots, it first checks its paired node's resourcesD . Nodes 1 and 3 and nodes 2 and 4 form node...

January 26, 2024 No Comments READ MORE +

What is the recommended configuration for the physical network interfaces?

There is a requirement to use dynamic link aggregation to maximize throughput and resiliency on a new Isilon cluster servicing SMB and NFS data. What is the recommended configuration for the physical network interfaces?A . FECB . Round robinC . Active/passive failoverD . LACPView AnswerAnswer: D

January 26, 2024 No Comments READ MORE +

What would satisfy the customer’s needs?

A customer wants to use their large Gen 6 Isilon cluster for ILM. All of their data is written to and read from a single file pool. They need to use multiple file pools, so slightly used data is stored on less expensive, large disks. Heavily used data is stored...

January 26, 2024 No Comments READ MORE +

How should you configure the switches and Isilon networking to provide your desired network redundancy?

Refer to the exhibit. You want to add redundancy to your network configuration, rather than performance. You have configured all interfaces into the default SmartConnect zone. How should you configure the switches and Isilon networking to provide your desired network redundancy?A . Configure the switch ports for LACP and use...

January 25, 2024 No Comments READ MORE +

What should be avoided when designing snapshot schedules?

What should be avoided when designing snapshot schedules?A . Setting an expirationB . Running the SnapshotDelete jobC . Manual snapshot deletionD . Using aliasesView AnswerAnswer: C

January 25, 2024 No Comments READ MORE +

What are two output options from the PowerScale cluster events log? (Select 2)

What are two output options from the PowerScale cluster events log? (Select 2)A . Hardware IssuesB . OneFS IssuesC . SMTP EmailD . LogsView AnswerAnswer: CD

January 25, 2024 No Comments READ MORE +