In which position would the power supply be replaced?

Refer to the exhibit: During a maintenance activity, support requested that the power supply PWS-A2 be replaced to resolve an issue with a PowerMax 8500. In which position would the power supply be replaced?A . 4B . 1C . 2D . 3View AnswerAnswer: D

March 13, 2024 No Comments READ MORE +

Which of the following is a key feature of the Simplified Symmwin tool for FRU procedures in PowerMax systems?

Which of the following is a key feature of the Simplified Symmwin tool for FRU procedures in PowerMax systems?A . It provides an automated scripting interfaceB . It allows for remote FRU managementC . It simplifies the procedure by providing step-by-step guidanceD . It is used for non-Dell EMC hardware...

March 13, 2024 No Comments READ MORE +

What type of RAID configuration does PowerMax 8500 support?

What type of RAID configuration does PowerMax 8500 support?A . RAID 1 and RAID 5 onlyB . RAID 6 and RAID 10 onlyC . Flexible RAID configurations, including RAID 5, 6, and DiamondD . Only proprietary Dell EMC RAID configurationsView AnswerAnswer: C

March 12, 2024 No Comments READ MORE +

Which model is more suitable for environments with high scalability and performance needs?

Which model is more suitable for environments with high scalability and performance needs?A . PowerMax 2000B . PowerMax 8000C . PowerMax 2500D . PowerMax 8500View AnswerAnswer: B

March 12, 2024 No Comments READ MORE +

Which software tool must be used by field personnel to start system management scripts on PowerMax systems?

Which software tool must be used by field personnel to start system management scripts on PowerMax systems?A . Solutions EnablerB . Simplified SymmwinC . SymmwinD . Unisphere for PowerMaxView AnswerAnswer: B

March 12, 2024 No Comments READ MORE +

Which power supplies in the graphic above must be replaced?

Refer to the exhibit: A service engineer was asked to replace both Zone A power supplies on a DME. Which power supplies in the graphic above must be replaced?A . 2 and 4B . 3 and 4C . 1 and 3D . 1 and 2View AnswerAnswer: B

March 12, 2024 No Comments READ MORE +

When replacing a FRU in PowerMax systems, what is a crucial step?

When replacing a FRU in PowerMax systems, what is a crucial step?A . Checking the power supply unitsB . Verifying the compatibility of the new FRUC . Reconfiguring the entire systemD . Updating the system's BIOSView AnswerAnswer: B

March 11, 2024 No Comments READ MORE +

Which two features are included in the PowerMax 2000 and 8000 Essentials software package?

Which two features are included in the PowerMax 2000 and 8000 Essentials software package? (Select 2)A . SRDFB . PowerPathC . D@RED . SnapVXE . AppSync StarterView AnswerAnswer: BE

March 11, 2024 No Comments READ MORE +

What are the two software packages offered for PowerMax 2000 and 8000 arrays?

What are the two software packages offered for PowerMax 2000 and 8000 arrays?A . Enterprise and InclusiveB . Essentials and EnterpriseC . Essentials and ProD . Inclusive and ProView AnswerAnswer: C

March 10, 2024 No Comments READ MORE +

What state is the battery in when the Li-Ion SPS battery position indicator is yellow?

What state is the battery in when the Li-Ion SPS battery position indicator is yellow?A . EngagedB . ParkedC . OffD . ConnectedView AnswerAnswer: B

March 9, 2024 No Comments READ MORE +