Which two items should the technician verify?
A technician needs to troubleshoot a server. The OS was operational. After an untrained person accesses the System Setup utility on the server, the OS now fails to load. The technician reboots the server, selects F2, accesses the System Setup utility, and selects System BIOS. The technician needs to verify...
What task should be completed to troubleshoot this issue?
An engineer needs to install an additional PSU on an existing, single PSU Dell EMC PowerEdge R740. They complete the initial installation and cabling procedures. They connect an AC cable and the power distribution unit produces normal AC output. The engineer checks power management and sees that the new PSU...
What is a valid password option available from the iDRAC9 Unique ID feature?
What is a valid password option available from the iDRAC9 Unique ID feature?A . Encryption DefaultB . Secure DefaultC . Legacy GeneratedD . Randomly GeneratedView AnswerAnswer: D
How should the technician obtain access to the remaining 2 TB (approximately) of storage?
A technician is creating a virtual disk in the DRAC (2x 4 TB NL-SAS in RAID 1) to install Windows 2016. They manually boot to the OS installation media without using the Lifecycle Controller OS Deployment wizard. Only the first 2048 GB on the virtual disk can be partitioned. How...
What is used by the Lifecycle Controller to directly back up the server profile on a 14G Dell EMC PowerEdge server?
What is used by the Lifecycle Controller to directly back up the server profile on a 14G Dell EMC PowerEdge server?A . vFlash SD cardB . USB Flash driveC . Network shareD . IDSDM SD cardView AnswerAnswer: C
How did this value change?
From PERC8 to PERC9, the maximum number of individual drives upon which a virtual disk can be created changed. How did this value change?A . 8 to 32B . 16 to 64C . 16 to 32D . 8 to 16View AnswerAnswer: B
What method can the technician use to quickly switch to DHCP?
Eight new servers have arrived at a datacenter. All use static IP addresses for iDRAC. The technician needs to enable these servers to contact the DHCP server on the network to obtain new IP addresses. What method can the technician use to quickly switch to DHCP?A . Reboot each server...
What is the reason for the failure?
A system administrator is trying to connect with a mobile device to a Dell PowerEdge 16G server using Quick Sync 2. They failed to make a connection. What is the reason for the failure?A . Bluetooth is disabled on the mobile device.B . NFC is disabled on the mobile device.C...
In addition to selecting the physical drive to be the hot spare disk, what tasks should the technician perform to set up the RAID controller?
A technician needs to install a server with a PERC RAID controller and 24, 2.5" SAS SED drives. The installation requires the following items to be created: - Three equal-sized virtual disks - Encrypted virtual disks - A global hot spare In addition to selecting the physical drive to be...
What is the reason for this issue not being reported to OME?
A user installed OME on a PowerEdge R640 server. OME has discovered and is currently monitoring another 30 remote PowerEdge 14G servers. Each server has the following configuration: - 2x CPUs - 384 GB RAM - 6x 1TB drives in a RAID 6 virtual disk - No hot spare drive...