The last two drive slots in a Dell EMC PowerStore 3000 are reserved for which type of drive?

The last two drive slots in a Dell EMC PowerStore 3000 are reserved for which type of drive?A . SAS SSDB . NVMe NVRAMC . NVMe SSDD . NVMe SCMView AnswerAnswer: B Explanation: Reference: https://volumes.blog/2020/05/05/whats-is-powerstore-part-2-hardware/#:~:text=On%20the%20PowerStore%201000%20and,(2)%20NVMe%20NVRAM%20devices.&text=PowerStore%20supports%20four%20types%20of,in%20specific%20locations%20and%20enclosures

February 14, 2024 No Comments READ MORE +

Which Midrange Sizer design path should you take?

You are designing a Dell EMC Unity solution. You need to model expected array performance based om IOPS capability, storage capacity, and RAID type. Which Midrange Sizer design path should you take?A . Application Oriented pathB . Performance Data Input pathC . System Designer pathD . Quick Configuration pathView AnswerAnswer:...

February 14, 2024 No Comments READ MORE +

Based on best practices which solution should the technical architect recommend?

A technical architect is designing a Dell Unity storage solution. The customer has a monthly data access profile where block data is accessed infrequently. The data is accessed frequently for a few days during month-end reporting. Based on best practices which solution should the technical architect recommend?A . A single-tier...

February 14, 2024 No Comments READ MORE +

Which parameters can be selected when sizing a Dell Unity XT 480F using the System Design method?

Which parameters can be selected when sizing a Dell Unity XT 480F using the System Design method?A . Drive count and RAID level Percentage of random writes and readsB . Data reduction ratio Percentage of sequential writes and readsC . One of four workload types Drive count and RAID levelD...

February 13, 2024 No Comments READ MORE +

What should be your response?

A customer has invested much time using the Dell PS Series Host Integration Toolkit (HIT) to integrate SAN snapshot protection with Microsoft SQL Server native snapshot technology. The customer expresses concern about whether Dell EMC SC Series cross-platform replication supports that capability. What should be your response?A . Recreate integration...

February 13, 2024 No Comments READ MORE +

What initiates an automatic NAS server failover to the peer SP?

What initiates an automatic NAS server failover to the peer SP?A . Network link failureB . Resource balancing algorithmC . Assisted internal migrationD . SP hardware faultView AnswerAnswer: D Explanation: An SP hardware fault initiates an automatic NAS server failover to the peer SP in Dell Unity systems. This ensures...

February 13, 2024 No Comments READ MORE +

Which SAS SSDs are supported by Dell EMC PowerStore?

Which SAS SSDs are supported by Dell EMC PowerStore?A . 960 GB, 1920 GB, 3840 GB, and 7680 GBB . 960 GB, 1920 GB, and 3840 GB onlyC . 1920 GB, 3840 GB, 7680 GB, and 15360 GBD . 1920 GB, 3840 GB, and 7680 GB onlyView AnswerAnswer: C Explanation:

February 13, 2024 No Comments READ MORE +

drag to right to correct sep

DRAG DROP drag to right to correct sep. View AnswerAnswer: Explanation: Diagram Description automatically generated

February 13, 2024 No Comments READ MORE +

What is the recommended minimum amount of Flash that they should specify?

A technical architect is designing a Dell Unity XT 480 using the System Designer option of Sizer. What is the recommended minimum amount of Flash that they should specify?A . 15%B . 7%C . 5%D . 10%View AnswerAnswer: B Explanation: 7% is the recommended minimum amount of Flash that a...

February 13, 2024 No Comments READ MORE +

What is the minimum number of drives required to expand the pool?

A customer has a Dell EMC Unity 680F array with a single pool consisting of 10 drives configured with RAID 5 (4+1). What is the minimum number of drives required to expand the pool?A . 1B . 5C . 6D . 7View AnswerAnswer: A