What is validated by running the Proactive VM Creation test in vCenter on a VxRail cluster?
- A . vSAN operates successfully
- B . Network firewalls are configured correctly
- C . vSAN has sufficient storage capacity
- D . Network performance is sufficient
A planned VxRail Stretched Cluster will have four All-Flash nodes at each site
What is the recommended storage policy to ensure cross-site and local protection, using storage as efficiently as possible?
- A . Site disaster tolerance – None – keep data on Preferred (stretched cluster) Failures to tolerate – 1 failure – RAID-5 (Erasure Coding)
- B . Site disaster tolerance – Dual site mirroring (stretched cluster) Failures to tolerate – 1 failure – RAID-5 (Erasure Coding)
- C . Site disaster tolerance – Dual site mirroring (stretched cluster) Failures to tolerate – 1 failure – RAID-1 (Mirroring)
- D . Site disaster tolerance – Dual site mirroring (stretched cluster) Failures to tolerate – no data redundancy
Which command can be used from the VxRail Manager VM to restart the loudmouth daemon?
- A . systemctl restart loudmouth
- B . /usr/lib/vmware/loudmouth/bin/loudmouthd restart
- C . /etc/init.d/loudmouth restart
- D . systemctl restart vmware-loudmouth
An implementation engineer is configuring External SRS.
Where can they find the installation files for SRS VE?
- A . VxRail Support Matrix
- B . VxRail Manager
- C . SolVe Online
- D . Dell Support Page
What is the maximum number of supported nodes for a VxRail cluster running on a 1 GbE network?
- A . 4
- B . 5
- C . 16
- D . 32
What is a consideration when performing a VxRail software upgrade from version 4.7.xxx to version 7.0.xxx?
- A . External vCenter server must be upgraded after the VxRail is upgraded
- B . vCenter Server requires a temporary IP address on a different subnet before the upgrade
- C . Secure boot must be enabled on the ESXi hosts for a successful upgrade
- D . VxRail Manager VM must be changed to the default name to avoid an upgrade failure
A VxRail Test Plan has been completed
What is the protocol for recording the results’?
- A . With the implementation team, complete and document each test, test date, and a screenshot of results
- B . In front of a customer, complete each test and document the test date
- C . With the implementation team, complete each test and document the test date
- D . In front of a customer, complete and document each test, test date, and a screenshot of results
Which VxRail model(s) has a non-mirrored IDSDM?
- A . D560/F
- B . All G Series
- C . S570
- D . All E Series
What is a consideration when adding nodes to a VxRail G Series chassis?
- A . G560 and G410 nodes are permitted in the same chassis
- B . In a full G Series chassis, all nodes must have 10GbE ports
- C . Hybrid and All-Flash nodes are permitted, if in different chassis
- D . All nodes in a G Series chassis must be identical
When preparing to generate an As-Built Configuration Report, it is determined that the VxRail Configuration JSON file was not saved from the Deployment Wizard .
What actions must be taken to retrieve the JSON file?
- A . SSH to the VxRail Manager VM with the mystic user
SU to root
Go to the /opt/VxRail/config directory
SCP the initial-config json file to a local location - B . Log in to vCenter with the vSphere Client with the vCenter Server Management user Go to Monitor > VxRail > Last Configuration Data Sent Use the Download option
- C . Open an FTP connection to the VxRail Manager VM with the mystic user
Go to the /var/lib/vmware-marvin directory
GET the config-initial json file - D . Log in to vCenter with the vSphere Client with the vCenter Administration user
Go to Configure > VxRail > System
Use the Product Documentation option
Which series of VxRail nodes supports either Intel or AMD processors and either hybrid or All-Flash storage?
- A . G Series
- B . D Series
- C . E Series
- D . V Series
CORRECT TEXT
A VxRail implementation engineer is validating the network environment with NVT. The proposed switch configuration is shown in the exhibit. The ToR Switch information file is available.
Use the VxRail simulator to set up NVT for switch validation. Import the switch Information and tag the ports based on the exhibit.
DRAG DROP
What is the correct sequence of steps to perform a RASR Factory Reset using an SD card?
An implementation engineer is tasked with setting up RecoverPoint for VMs on a new 4-node E Series VxRail duster How many VMs are licensed to be protected on the cluster?
- A . 5
- B . 10
- C . 20
- D . 25
An implementation engineer logs in to the vSphere Client of a recently deployed VxRail cluster. They want to review the firmware versions on the VxRail nodes.
Which view should they use to gather this information?
- A . Hosts and Clusters > VxRail Host > Configure > VxRail > iDRAC Configuration
- B . Host and Clusters > VxRail Host > Monitor > VxRail > Physical View
- C . Hosts and Clusters > VxRail Cluster > Monitor > VxRail > Appliances
- D . Hosts and Clusters > VxRail Cluster > Configure > VxRail > System
Where can an administrator find steps to perform a manual verification of the customer network?
- A . Customer Simplified Form
- B . Dell EMC VxRail Network Planning Guide
- C . Pre-Engagement Questionnaire (PEQ)
- D . Dell Technologies SolVe Online
Which VxRail model can only be installed with static rack rails?
- A . D Series
- B . P Series
- C . S Series
- D . G Series
A VxRail cluster 4.7.xxx environment is managed by the internal vCenter Server. An implementation engineer plans to deploy a new VxRail cluster using the existing vCenter Server instance, then use the
customer-supplied VDS to manage both VxRail clusters.
What must be done?
- A . Migrate the internal vCenter Server to an external vCenter Server, then merge the PSC
- B . Upgrade the VxRail version from 4.7.xxx to 7.0.000
- C . Migrate the internal vCenter Server to an external vCenter Server, then upgrade the VxRail 4.7.xxx to 7.0.100
- D . Upgrade the internal vCenter Server to version 7.0
What is a requirement for the vSAN Data-at-Rest Encryption?
- A . All-Flash or AII-NVMe VxRail
- B . VxRail with at least 3 nodes
- C . External Key Management Server
- D . External customer provided vCenter
An implementation engineer is reviewing the customer requirements for a VxRail implementation. The customer has specified noncontiguous hostnames and IP addresses
What option should the engineer select in the VxRail Deployment Wizard to input the hostnames and IP addresses?
- A . Autofill – with the correct incrementor
- B . Advanced
- C . Autofill – with the correct offset
- D . Custom
What is a valid 2-node VxRail cluster configuration?
- A . 2x 10 GbE and 2x 25 GbE in a switch configuration and external vCenter
- B . 2x 1 GbE and 2x 10 GbE in a direct-connect configuration and external vCenter
- C . 2x 1 GbE and 2x 10 GbE in a switch configuration and internal vCenter
- D . 2x 10 GbE and 2x 25 GbE in a direct-connect configuration and internal vCenter
What is a valid 2-node VxRail cluster configuration?
- A . Series with 4x 25 GbE in a direct-connect configuration
- B . Series with 4x 10 GbE in a switch configuration
- C . Series with 4x 1 GbE in a direct-connect configuration
- D . Series with 2x 25 GbE in a switch configuration
A company needs to enable vSphere GPU capabilities on their VxRail cluster. To do so, they need to purchase a specific entitlement.
What licensing satisfies this requirement?
- A . vSphere Enterprise Plus
- B . vSAN Enterprise Plus Edition
- C . vSAN Advanced Edition
- D . vSphere Standard
A VxRail Manager VM must be configured as follows:
* IP address: 192 168.10.16
* Net mask: 255.255.255.0
* Gateway: 192 168 10 254
Which command must be used?
- A . vxrail-network-config –ip 192 168 10.16-netmask 255.255.255.0-gateway 192 168 10.254
- B . vxrail-prrmary -config –ip 192 168 10 16 -netmask 255 255 255 0 -gateway 192 168 10 254
- C . vxrail-primary -config –vxrail-address 192.168.10 16 –vxrail-netmask 255 255 255 0 – vxrail-gateway 192.168,10 254
- D . vxrail-network -config –vxrail-address 192.166 10 16 –vxrail-netmask 255 255.255 0 — vxrail-gateway 192.168.10.254
Which command is used to restart the Loudmouth process on an ESXi node?
- A . /usr/IibAmiware/loudmouth/bin/loudmouthd restart
- B . systemcti restart loudmouth
- C . /etc/int.d/loudmouth restart
- D . systemcti restart vmware-loudmouth
An implementation engineer is tasked with setting up RecoverPoint for VMs on a single G Series chassis .
How many VMs are licensed to be protected on the cluster?
- A . 5
- B . 10
- C . 15
- D . 20
During the activation of Internal SRS, the implementation engineer receives a message that the deployment has failed
What is a possible cause?
- A . SRS VE Gateway on the same subnet as the VxRail Manager
- B . VxRail status already set to installed’ in IB database
- C . Site ID mismatch between the IB database and the SRS Wizard
- D . Witness Gateway not configured following Dell best practices
An implementation engineer places a VxRail node into maintenance mode using the Ensure accessibility setting
What is the engineer likely planning to do?
- A . Extensive maintenance
- B . Temporary maintenance
- C . Permanent removal of host from cluster
- D . Shutdown of an entire cluster
An implementation engineer is performing a precheck on a VxRail cluster before expansion. During validation, they find out that the host is not compatible.
Use the VxRail simulator to describe why the host is Incompatible.
Note: It is necessary to close (x) the simulator window before you can select a response to this question.
- A . bmc and bios are running older versions
- B . Insufficient number of vSphere licenses
- C . Firmware of ESXi host needs to be updated
- D . Invalid vCenter 5erver license
What data protection option is included with VxRail?
- A . vSphere Replication NetWorker
- B . PowerProtect Software Data Domain Cloud Tier
- C . RecoverPoint for VM vSphere Replication
- D . RecoverPoint for VM Avamar
Which service determines the primary node after powering on the VxRail nodes during the deployment of a VxRail cluster?
- A . Loudmouth
- B . Election
- C . Marvin
- D . Mystic
What is a consideration when expanding a VxRail cluster? (Choose two.)
- A . Mixing of All-Flash and all-NVMe nodes in a cluster is not allowed
- B . Expanding a cluster to 64 nodes requires a 25 GbE network
- C . G Series clusters can be expanded only with G Series nodes
- D . 1 GbE must be hybrid and single processor node type
A systems engineer is performing a VxRail upgrade in a VMware Horizon VDI cluster All hosts are put in Maintenance Mode.
What action does the engineer need to perform on each host once the upgrade has been completed?
- A . From the Connection Server run IcMaintcmd to delete the parent VMs and exit Maintenance Mode for each host
- B . From the Connection Server, run IcMaintcmd to take the hosts out of Maintenance Mode and reboot them
- C . Set the InstantClone Maintenance annotation value to the original value
- D . Set the InstantClone Maintenance annotation value to 2
The VxRail Deployment Wizard is being used on a VxRail cluster with a customer-supplied VDS .
Which settings must be used to ensure successful installation?
- A . Use the VxRail vCenter Server
Upload a configuration file (JSON) - B . Join an external vCenter Server
Use the step-by-step method - C . Use the VxRail vCenter Server
Use the step-by-step method - D . Join an external vCenter Server
Upload a configuration file (JSON)
Which two files are used to automate VxRail deployment and validate the network configuration?
- A . Appliance JSON file
PEQ data file - B . VxRail Configuration Portal
PEQ data file - C . VxRail Test Plan
SPEQ - D . Appliance JSON file
SPEQ
What is validated by running the Proactive Network Performance test in vCenter on a VxRail cluster?
- A . Latency and bandwidth measurement to the witness host
- B . Network configuration and performance for vSAN
- C . Network performance for virtual machines
- D . Latency measurement between DCs for Stretched Clusters
DRAG DROP
Match each VxRail API request with the information to be retrieved.
In addition to hardware monitoring, what is the purpose of the Dell PTAgent service on a VxRail node?
- A . Hardware discovery and firmware installation
- B . VxRail node discovery and software upgrades
- C . BOSS upgrade and firmware installation
- D . Hardware discovery and VxRail VIB installation
What is the minimum number of VxRail nodes required for a vSAN storage policy with RAID-6 (Erasure Coding)?
- A . 4
- B . 5
- C . 6
- D . 7
A VxRail cluster is being deployed in a DMZ environment .
What is the recommended deployment option?
- A . External vCenter Server with customer-supplied VDS
- B . External vCenter Server with VxRail-deployed VDS
- C . Internal vCenter Server with internal DNS
- D . Internal vCenter Server with external DNS