What components of a VxRail node must be assigned IP addresses?
- A . ESXi host. Center. ESRS. and iDRAC
- B . ESXi host, vSAN. Center. and ESRS
- C . ESXi host, vSAN. vMouon. and iDRAC
- D . vSAN. Center. vRealize Log Insight. and vMotion
A system administrator wants to check the version of the VxRail Manager Plug-In.
Where can this be done?
- A . vSphere Client > VxRail Cluster > Configure> VxRail Support
- B . vSphere Client > Menu Administration > Client Plug-Ins
- C . vSphere Web Client > Menu Administration > Client Plug-Ins
- D . VxRail Manager URL > System Health > Client Plug-Ins
What is the maximum number of nodes in a VxRail Cluster with 25 GbE?
- A . 32
- B . 64
- C . 96
- D . 128
Beginning with VxRail version 4.7, which product license option has changed?
- A . VSAN
- B . vCenter
- C . VMware Log Insight
- D . vSphere
What type of license does the Dell 4100 OS 10 Switch require to support SmartFabric Services beyond the initial trial period?
- A . Feature specific licensing for SmartFabric Services
- B . Full Fabric Mode licensing
- C . SmartFabric licensing
- D . Perpetual licensing
A VxRail Cluster setup with P570F nodes is used for product evaluation purposes at customer sites. Before moving the Cluster to another customer site. it needs to be reset.
Where is the image located to complete this task?
- A . MB Server
- B . IDSDM
- C . SATADOM
- D . BOSS
How long does it take for the Primary node to be selected for a VxRail deployment after all nodes have been powered on?
- A . 15 to 20 seconds
- B . 5 to 10 minutes
- C . 5 to 10 seconds
- D . 15 to 20 minutes
What are all of the menu option choices available in the RASR factory reset procedure when booting from the RASR ISO?
- A . RASR RESET
CREATE RASRUSB
FACTORY RESET
UPDATE FIRMWARE
EXIT - B . RASR RESET
CREATE RASRUSB
FACTORY RESET
REBOOT
UPDATE FIRMWARE
QUIT - C . RASR RESET
CREATE RASRUSB
FACTORY RESET
QUIT - D . RASR RESET
CREATE RASRUSB
FACTORY RESET
REBOOT
UPDATE FIRMWARE
EXIT
You are validating a VxRail deployment of six V570F nodes each with four 10 Gb connections. The VxRail nodes have not been powered on.
You need to ensure that the Dell EMC ToR switch is configured correctly.
Which command should you use to do this?
- A . show port-channel summary
- B . show interface status
- C . show interface trunk
- D . show running-config
How many nodes can be added simultaneously to an easting VxRail Cluster?
- A . 1
- B . 2
- C . 4
- D . 6
You have determined that you need to execute a RASR factory upgrade of a VxRail v4.7.1xx node. You download the RASR ISO from the Dell Support site.
What is the correct order of steps to finish the upgrade?
What VxRail VSAN storage policy should NOT be changed or deleted after the initial setup?
- A . VM Encryption Policy
- B . VSAN Default Storage Policy
- C . VxRAIL-STORAGE-PROFILLE
- D . VxRAIL-SYSTEM-STORAGE-PROFILE
In which VxRail models is the iDRAC NIC Selection Setting set to Dedicated?
- A . P570, V570, and S570 only
- B . E560 and G560 only
- C . P570, V570, S570 and G560
- D . E560, P570. V570, and S570
What is the correct sequence of steps used by the VxRail NVT workflow?
What is the primary use of the VxRail PEQ Addendum?
- A . Specifying Dell EMC- deployed switches and Stretched Clusters
- B . Generating the NVT/FDC JSON configuration file
- C . Deploying customer provided, non-Dell EMC network switches
- D . Manually configuring VxRail Manager
What is the default VLAN ID of the Private Management VLAN network on a VxRail 4.7.x node?
- A . 0
- B . 1
- C . 3939
- D . 4095
Where are the vSAN logs stored?
- A . Standard ESXi host logs
- B . Master vSAN node
- C . VSAN appliance VM
- D . vCenter logs
By design, which network is required to have IPv6 Multicast enabled in order to set up a VxRail with version 4.7.100?
- A . Public management network
- B . VSAN network
- C . vMotion network
- D . Private management network
Which requirement must be met when expanding a VxRail G560F 3 node Cluster with a 4th G Series node in the same chassis?
- A . Node must be a hybrid node
- B . Node requires only the same processor type
- C . Node requires only the same drive configuration
- D . Node must be identical to the other three nodes
During a VxRail 2 node Cluster deployment, what is a valid connectivity option?
- A . 2×10 GbE
- B . 4×25 GbE
- C . 4 x1 GbE
- D . 2×25 GbE
A VxRail Stretched Cluster will be configured with four All-Flash nodes at each site based on the following requirements:
– PFTT=1
– SFTT=1
– FTM=Erasure Coding
Based on the required usable capacity, what should be the planned capacity of the design?
- A . Single Site Capacity=200%
Total Cluster Capacity=400% - B . Single Site Capacity= 133%
Total Cluster Capacity=266% - C . Single Site Capacity = 100%
Total Cluster Capacity= 200% - D . Single Site Capacity=150%
Total Cluster Capacity=300%
You have just upgraded a VxRail Cluster from version 4.5.x to version 4.7.x. You need to ensure that new VxRail 4.7.x nodes will be discovered without having to make any changes to the nodes.
What action should you take on the existing configuration?
- A . In vCenter, set the VLAN ID of the Management Network distributed portgroup to 3939
- B . Add a new VLAN to the ToR switches with ID 3939
- C . Add a new VLAN to the ToR Switches with ID 3939
In vCenter, set the VLAN ID of the Management Network distributed portgroup to 3939 - D . Add a new VLAN to the ToR switches with ID 3939
In vCenter, set the VLAN ID of the VxRail Management distributed portgroup to 3939
What is the default network traffic configuration for a VxRail node with 2 x 10 GbE ports?
- A . Management, vMotion, and Virtual Machines on Uplink1
VSAN on Uplink - B . Management and vMotion on Uplink1
VSAN and Virtual Machines on Uplink2 - C . Management and virtual Machines on Uplink1
VSAN and vMotion on Uplink2 - D . Management Virtual Machines, and VSAN on Uplink1
vMotion on Uplink2
Which settings would you expect to find in the VXRAIL-SYSTEM-STORAGE-PROFILE?
- A . FTT = 1
Object space reservation (%) =0 - B . FTT = 2
Object space reservation (9o) =0 - C . FTT = 2
Object space reservation (%) =100 - D . FTT = 1
Object space reservation (%) =100
In a VRail Stretched Cluster deployment. what is the required Round Trip Time (RTT) between sites?
- A . Primary to Witness site RTT: < 150 ms
Secondary to Witness site RTT: < 150 ms
Primary to Secondary site RTT: < 10 ms - B . Primary to Witness site RTT: < 250 ms
Secondary to Witness site RTT: < 250 ms
Primary to Secondary site RTT: < 10 ms - C . Primary to Witness site RTT: < 200 ms
Secondary to Witness site RTT: < 200 ms
Primary to Secondary site RTT: < 5 ms - D . Primary to Witness site RTT: < 10 ms
Secondary to Witness site RTT: < 10 ms
Primary to Secondary site RTT: < 6 ms
What is the minimum number of VxRail nodes required for a SAN storage policy with FTT = 2 and FTM set to Erasure Coding?
- A . 4
- B . 5
- C . 6
- D . 7
What command is used to restart the Loudmouth process on a VxRail node?
- A . /usr/lib/vmware/loudmouth/bin/loudmouth restart
- B . systemctl restart loudmouth
- C . systemctl restart vmware-loudmouth
- D . /etc/init.d/loudmouth restart
A VxRail solution will be deployed with the embedded VCenter and Log Insight. Prior to deployment, DNS records must be created for which entities?
- A . vCenter Server, ESXi hosts. VxRail Manager, and Log Insight only
- B . vCenter Server, Platform Services Controller ESXi hosts, VxRail Manager, and Log Insight only
- C . ESXi Hosts, VxRail Manager Log Insight, and iDRAC only
- D . vCenter Server, Platform Services Controller ESXi hosts, VxRail Manager, Log Insight, and iDRAC
What data protection methods are included with the VxRail Appliance?
- A . Stretched Clusters
NetBackup
vSphere Replication - B . Stretched Clusters
RecoverPoint for VMs
vSphere Replication - C . vSphere Replication
RecoverPoint for VMs
Avamar - D . RecoverPoint for VMs
Data Domain
Stretched Clusters
What are the categories that can be validated by the VxRail NVT?
- A . Network Services, TOR Switches and Upstream Switches
- B . TOR Switches and Upstream Switches only
- C . VxRail Appliance, Network Services, and ToR Switches
- D . VxRail Appliance, ToR Switches, and Upstream Switches