DELL EMC DES-4122 Specialist – Implementation Engineer PowerEdge Version 2.0 Online Training
DELL EMC DES-4122 Online Training
The questions for DES-4122 were last updated at Nov 19,2024.
- Exam Code: DES-4122
- Exam Name: Specialist - Implementation Engineer PowerEdge Version 2.0
- Certification Provider: DELL EMC
- Latest update: Nov 19,2024
A technician is creating a virtual disk in the iDRAC (2x 4 TB NL-SAS in RAID 1) to install Windows 2016 They manually boot to the OS installation media without using the Lifecycle Controller OS Deployment wizard Only the first 2048 GB on the virtual disk can be partitioned
How should the technician obtain access to the remaining 2 TB (approximately) of storage?
- A . Use the Lifecycle Controller OS Deployment Wizard to deploy the OS on this server
- B . Delete the 4 TB virtual disk and create a virtual (boot) disk no larger than 2048 GB
- C . Upgrade to a newer version of the operating system
- D . Use F2 to go into the BIOS, change the BIOS boot mode to UEFI, and try again
Where is the data stored to allow Easy Restore to successfully complete a system board replacement?
- A . NAND Flash module on the disk drive mid plane
- B . IDSDM SD card
- C . vFlash SD card
- D . Serial Flash storage in the server’s front panel
A technician needs to repurpose a Dell EMC PowerEdge server. The server has dual processors with 18 cores each The OS only "sees" 24 threads in total.
Which setting should the technician change in Processor Settings in the System BIOS?
- A . System Profile
- B . Virtualization Technology
- C . HyperThreading
- D . Number of Cores per Processor
What are the default settings used when applying firmware and a configuration to a replaced part using the Lifecycle Controller?
- A . Firmware: Upgrade to latest available version
Configuration Apply always - B . Firmware Allow version upgrade only
Configuration: Disabled - C . Firmware: Match firmware of replaced part
Configuration Apply always - D . Firmware Disabled
Configuration Apply only if firmware match
What is the purpose of the Silicon-Based Hardware Root of Trust feature in Dell EMC PowerEdge 14G servers?
- A . Ensures that the installed operating system is authentic
- B . Ensures that the server has a valid Service Tag number
- C . Ensures that no unauthorized BIOS or firmware codes are run
- D . Ensures that the server boots only when connected to a verified network
DRAG DROP
Match each status LED indicator on the Dell EMC 14G PowerEdge server with its corresponding condition.
An engineer is checking a newly delivered Dell EMC PowerEdge R640 server that will be deployed for a new database environment.
The inventory consists of:
The server power configuration will be set for gnd redundancy. The management switch is 1000 Base-T and the top of rack switches 10Gb
What additional component(s) is needed for this configuration?
- A . Hot-plug power supply, 750 W – qty 1
- B . Hot-plug power supply, 1100W – qty 1
- C . Dell Networking, cable, 40GbE (QSFP+) to 4 x 10GbE SFP+ passive copper breakout cable, 3 meters – qty 2
- D . C20 to C21, PDU style, 250 V, 16 Amp, 3 5 meters power cord – qty 2
What is a systems management console solution optimized for monitoring and managing Dell enterprise and remote office hardware?
- A . SupportAssist Enterprise
- B . iSM
- C . OpenManage Essentials
- D . iDRAC9
DRAG DROP
Refer to the exhibit.
Match each callout to the Dell EMC PowerEdge server model shown.
After completing a disk rebuild operation, a technician needs to configure the system so that the rebuild process happens faster the expense of slowing users down.
Which setting should be changed?
- A . Rebuild Rate in the BIOS settings
- B . System Profile to Performance in the BIOS settings
- C . System Profile to Performance in the iDRAC GUI
- D . Rebuild Rate in the iDRAC GUI