DELL EMC DES-1D11 Specialist, Technology Architect | Midrange Storage Solutions Online Training
DELL EMC DES-1D11 Online Training
The questions for DES-1D11 were last updated at Nov 23,2024.
- Exam Code: DES-1D11
- Exam Name: Specialist, Technology Architect | Midrange Storage Solutions
- Certification Provider: DELL EMC
- Latest update: Nov 23,2024
A customer wants to replace a PowerVault MD that has SAS-connected rack-mount 13G PowerEdge servers. The servers need to remain unmodified.
Which Dell EMC SC Series solution is recommended?
- A . SCv2000 and SC8000
- B . SC4020 and SCv2000
- C . SC4020 and SC8000
- D . SC9000 and SC8000
A customer wants to add self-encrypting SSDs to a Dell EMC SC8000 system running SCOS version 6.5. They have deployed a SafeNet Key Management server in the network.
Does the customer need to do anything else?
- A . No. Add and manage the SSDs in the disk folder.
- B . Yes. Upgrade the hardware to SC9000 and SC220 enclosures.
- C . Yes. Upgrade to SCOS 6.7 release or newer.
- D . Yes. Add a new enclosure exclusively for the SSDs.
Which Dell EMC tool uses an HTML5 interface and best practices to predict storage performance?
- A . Unity Sizer
- B . Unity Designer
- C . MiTrend
- D . Analyzer Helper
Why is the drive size a threshold in Dell EMC SC Series for Dual Redundancy?
- A . RAID protection level during a disk allocation failure
- B . RAID stripe reconstruction time during a disk failure
- C . Data Progression run times are longer with larger drives
- D . Cost per GB on larger drives is less
Which Dell EMC Unity technology is the Local LUN Move feature architecture built upon?
- A . Inband Migration Tool
- B . Copy on First Write
- C . SanCopy Push
- D . Transparent Data Transfer
Using customer-supplied information, you have designed a solution using a Dell EMC Unity 400F with 250 drives. The customer now wants to increase the drive count to 340 drives at the lowest cost.
Which Unity model configuration should be recommended?
- A . Keep the Unity 400F and add two 80-drive DAEs
- B . Keep the Unity 400F and add four 25-drive DAEs
- C . Upgrade to a Unity 500F and add two 80-drive DAEs
- D . Upgrade to a Unity 500F and add two 25-drive DAEs
What are the Dell EMC midrange storage offerings for capacity efficiency?
- A . Unity: Compression and Post-Process DeduplicationSC Series: Inline Compression
- B . Unity: Intelligent Compression and DeduplicationSC Series: Inline Compression and Deduplication
- C . Unity: Post-Process Compression and DeduplicationSC Series: Inline Compression and Deduplication
- D . Unity: Compression for BlockSC Series: Intelligent Compression and Deduplication
Which logical drives are reserved for the Dell EMC Unity operating system?
- A . Drives 0 C 3 on 12-drive and 25-drive DPE models
- B . Drives 0 C 3 on only a 12-drive DPE modelDrives 1 C 4 on only a 25-drive DPE model
- C . Drives 0 C 3 on only a 25-drive DPE modelDrives 1 C 4 on only a 12-drive DPE model
- D . Drives 1 C 4 on 12-drive and 25-drive DPE models
A Dell EMC SC7020 contains the following drives:
-Tier 1: Write-intensive SSDs
-Tier 2: Read-intensive SSDs
-Tier 3: 7K HDDs
Which tier(s) will qualify for deduplication and compression?
- A . Tier 1 only
- B . Tier 1 and Tier 3 only
- C . Tier 1, Tier 2, and Tier 3
- D . Tier 2 and Tier 3 only
To maximize system performance on Dell EMC Unity systems, what is recommended?
- A . Distribute Flash drives across back-end buses
- B . Use a 12-drive DPE with only Hybrid systems
- C . Build storage pools with only a minimum number of drives
- D . Distribute host connections across as few front-end ports as possible