DELL EMC DEE-1721 Expert – Implementation Engineer, SC Series Exam Online Training
DELL EMC DEE-1721 Online Training
The questions for DEE-1721 were last updated at Jan 30,2025.
- Exam Code: DEE-1721
- Exam Name: Expert – Implementation Engineer, SC Series Exam
- Certification Provider: DELL EMC
- Latest update: Jan 30,2025
You map a volume to a Microsoft Windows 2012 R2 server and scan for disks within the Windows Disk Management Console. You are able to see multiple Instances of the mapped volume. In addition, the operating system was recently installed on the server that is experiencing the issue. No additional features have been added.
Which action should occur within Windows to correct the issue?
- A . Add the Storage Center specific harware ID within Windows MPIO
Select the disk object with the lowest number and delete the rest
Verify the iSCSI Initiator service runs on the server - B . Add the Storage Center specific harware ID within Windows MPIO
Add the “Multipath I/O” server feature
Reboot the server after making the correct configuration changes - C . Select the disk object with the lowest disk number and delete the rest
Add the “Multipath I/O” server feature
Reboot the server after making the correct configuration changes
Verify the iSCSI Initiator service runs on the server
You notice that servers connecting through iSCSI are not performing as expected. After reviewing the graphics, you identify high latency due to an excessive number of retransmissions.
What is causing the performance issue?
- A . System uses the standard MTU size
- B . Switch firmware is out of date
- C . VLAN ID value is set on the properties of the server NIC
- D . Flow Control is disabled
A deployment engineer is installing a dual-controller Storage Center with four FC ports in each controller. This system need to use Legacy Port mode because the AIX version used requires it.
Which two configurations are required to set up the fault domains?
- A . Only two fault domains; one for the primary ports and one for the reserved ports
Primary and reserved ports in the fault domain need to reside on the same controller - B . Only two fault domains; one zone for all ports in each fabric
Primary and reserved ports in the fault domain need to reside on the different controllers - C . A separate fault domain for each set of primary and reserved ports
Primary and reserved ports in the fault domain need to reside on different controllers - D . A separate fault domain for each set of primary and reserved ports
Primary and reserved ports in the fault domain need to reside on the same controller
You want to perform an SCOS ISO update.
However, you need to determine the BMC IP address first.
What is one way to determine the BMC IP address?
- A . Select the “Hardware” tab from the Data Collector to display the BMC IP address for each controller
- B . Select the “Storage Centers” tab from the Data Collector to display the BMC IP address for each controller
- C . In the Dell Storage Manager Client, highlight the controller under the “Hardware” tab and select Edit Settings
- D . Perform a trace route from the controller CLI to the virtual IP address
A company experienced complete storage outages on some of their servers. The outages occurred when network maintenance was performed within their iSCSI network.
Which configuration areas should be investigated to prevent future outage?
- A . Ensure Delayed Acknowledgment has been disabled on the iSCSI adapters.
Ensure all server iSCSI adapter are able to communicate with the storage. - B . Ensure the servers are set up for multipathing with Round Robin.
Ensure Deplayed Acknowledgment has been disabled on the iSCSI dapters. - C . Ensure the iSCSI adapters are set up for Jumbo Frames.
Ensure all server iSCSI adapters are able to communicate with the storage. - D . Ensure the servers are set up for multipagthing with Round Robin
Ensure all server iSCSI adapters are able to communicate with the storage.