DELL EMC DEE-1721 Expert – Implementation Engineer, SC Series Exam Online Training
DELL EMC DEE-1721 Online Training
The questions for DEE-1721 were last updated at Jan 30,2025.
- Exam Code: DEE-1721
- Exam Name: Expert – Implementation Engineer, SC Series Exam
- Certification Provider: DELL EMC
- Latest update: Jan 30,2025
Refer to the Exhibit:
If a user expires Replay 2, which page(s) is deleted?
- A . A1 only
- B . A1 and C1
- C . B, D, and E
- D . C1 only
A storage administrator wants to perform an SCOS update to SCOS version 6.7.5. The SC Series is currently at SCOS version 6.5.30. The SC Series storage array is located at a secure facility and does not allow connectivity to any network outside the facility.
The Administrator is attempting to use the Storage Center Update Utility to accomplish this task but has been unsuccessful.
What is the reason for this Issue?
- A . Storage Center has not passed pre-upgrade checks and is blocking the update
- B . Storage Center is not at the minimum required SCOS version to use the utility
- C . Storage Center is not licensed to use the Storage Center Updated Utility
- D . Secure facility is not allowing the administrator’s laptop to connect to the Storage Center across the network.
A site has multiple storage administrators. Some administrators need to be limited to manage only specific volumes. The administrator should be able to create and present volumes within the administrator’s area. Those administrators should NOT be able to see any other volumes created in the Storage Center.
How should the deployment engineer accomplish tins task?
- A . Grant the administrator Volume Manager access. Create server folders and move the desired volumes into them, then assign the server folder to the desired administrator.
- B . Grant the administrator Admin user access. Create server folders and move the desired volumes into them then assign the server folder to the desired administrator.
- C . Grant the administrator Volume Manager access. Create volume folders and move the desired volumes into them, then assign the volume folder to the desired administrator.
- D . Grant the administrator Admin user access. Create volume folders and move the desired volumes into them, then assign the volume folder to the desired administrator.
A company has a four-node Microsoft Windows cluster that runs Microsoft SQL Server databases. Each server boots from its own Boot from SAN volume on the Storage Center. All servers need access to the database volumes. In addition, a server cluster objects has been created with the four servers assigned to it in Dell Storage Manager.
How should the volumes be mapped to these servers using the server cluster?
- A . Map the boot volume of each server individually
Map all database volumes to the cluster’s Leader node - B . Map the boot volume of each server individually
Map all database volumes to the server cluster - C . Map all boot volumes to the server cluster
Map all database volumes to each server individually - D . Map all boot volumes to the server cluster
Map all database volumes to the server cluster
You need to install a dual controller Storage Center with an SC200 enclosure and an SC280 enclosure.
Which exhibit represents the correct back-end cabling?
A)
B)
C)
D)
- A . Option A
- B . Option B
- C . Option C
- D . Option D
You are adding a 4-port FC card into the SC9000 storage array. Slots 4 C 6 are occupied and Slot 4 contains a half-height card.
Which actions should occur to free up the full height slot and add the FC card?
A)
B)
C)
D)
- A . Option A
- B . Option B
- C . Option C
- D . Option D
A company has multiple Storage Centers at their primary site and a disaster recovery system at their remote site. Because there company has an important volume that request high availability protection, an outage on one system at the primary location must not cause data to be inaccessible. In addition, disaster recovery protection is required to protect data even if the primary site goes down.
Which recommended technology meets these requirements?
- A . Live Volume Managed Replication
- B . Fluid Data Architecture
- C . Synchronous Replication
- D . Asynchronous Replication
During the deployment of an SC Series storage array, the redundancy of a tier may be restricted dual redundancy.
What is the cause for this behavior?
- A . Depending on the drive firmware level and drive sire, Dell Storage Manager will enforce dual redundancy
- B . Depending on the drive speed, drive sire, and SCOS version, dual redundancy may be enforced
- C . Depending on the drive manufacturer and SCOS version, Del Storage Manager will enlace dual redundancy
- D . Depending on the number of spares configured on the system and SCOS version, dual redundancy may be enforced
You need to physically install an I/O card into an SC9000 storage array.
What must be considered when installing the I/O card?
- A . I/O card BIOS and IPC connection
- B . ESD and I/O slot priority
- C . I/O slot priority and I/O card BIOS
- D . IPC connection and ESD
A storage administration needs to enable regular Data Progression to move data between storage tiers. While navigating through the Volume Create wizard, which storage profile should be selected?
- A . Low Priority
- B . Medium Priority
- C . High Priority
- D . Recommended