DELL EMC D-VXR-DY-23 Dell Technologies VxRail Deploy 2023 Online Training
DELL EMC D-VXR-DY-23 Online Training
The questions for D-VXR-DY-23 were last updated at Jan 31,2025.
- Exam Code: D-VXR-DY-23
- Exam Name: Dell Technologies VxRail Deploy 2023
- Certification Provider: DELL EMC
- Latest update: Jan 31,2025
What is the complete list of menu option choices available in the RASR factory reset procedure when booting from the RASR ISO?
- A . – RASR RESET
– CREATE RASRUSB
– FACTORY RESET
– REBOOT
– UPDATE FIRMWARE
– QUIT - B . – RASR RESET
– CREATE RASRUSB
– FACTORY RESET
– UPDATE FIRMWARE
– EXIT - C . – RASR RESET
– CREATE RASRUSB
– FACTORY RESET
– REBOOT
– UPDATE FIRMWARE
– EXIT - D . – RASR RESET
– CREATE RASRUSB
– FACTORY RESET
– QUIT
An implementation engineer is validating a VxRail deployment of six V570F nodes, each with four 10 Gb connections. The VxRail nodes have not been powered on.
Which command should they run to confirm that the Dell EMC ToR switch is configured correctly?
- A . show port-channel summary
- B . show interface status
- C . show lldp neighbors
- D . show running-config
A customer is performing self-deploy of a VxRail cluster. The VxRail Deployment Wizard fails to launch. The software appears to be corrupted.
What should they do to address the issue?
- A . Use the VMware Host Client and iDRAC to access the nodes and troubleshoot the issue.
- B . Verify that the Configuration file is not corrupt and has all the required values.
- C . Use the vSphere Client and troubleshoot the issue.
- D . Contact Dell support and request the nodes be reimaged.
Which VxRail node type support only hybrid storage?
- A . S Series
- B . E Series
- C . G Series
- D . V Series
Which functionality is provided by the VxRail Physical View for a node?
- A . Hardware alerts, LED indicator activation, and initiating power supply replacement
- B . Hardware alerts, BIOS and firmware versions, and initiating disk replacement
- C . LED indicator activation, initiating disk replacement, and BIOS parameter change
- D . BIOS and firmware versions, cluster shutdown, and initiating BIOS and firmware update
A VxRail cluster 4.7.xxx environment is managed by the internal vCenter Server. An implementation engineer plans to deploy a new VxRail cluster using the existing vCenter Server instance, then use the customer-supplied VDS to manage both VxRail clusters.
What must be done?
- A . Migrate the internal vCenter Server to an external vCenter Server, then merge the PSC
- B . Upgrade the VxRail version from 4.7.xxx to 7.0.000
- C . Migrate the internal vCenter Server to an external vCenter Server, then upgrade the VxRail 4.7.xxx to 7.0.100
- D . Upgrade the internal vCenter Server to version 7.0
When validating the VxRail health just after the VxRail initial configuration, there is a red exclamation mark on the MARVIN-Virtual-SAN-Cluster and the reported health alarm is ‘Component metadata health’.
A "Retest" action in the health service panel is performed and all the nodes in the cluster show health status as failed with the invalid state. Investigation does not reveal any hardware issues with the disks in use by vSAN.
What action should be taken next?
- A . Wait 24 hours, then click the "Retest" button again
- B . Apply the vSphere ESXi600-201611001 patch, then click the "Retest" button again
- C . Evacuate and destroy the disk/disk group that contains the component(s) reporting errors and clear the alarm
- D . Reapply the MARVIN storage policy to the VxRail internal virtual machines
Which vSAN license is included with VxRail?
- A . vSAN Enterprise
- B . vSAN for ROBO
- C . vSAN Advanced
- D . vSAN Standard
A VxRail E560F model was delivered six months ago and is now scheduled to be installed with the target code.
What is the correct order of steps to complete this task?
What is the base URL for the VxRail API call?
- A . http://<VxM_IP>/vxm/v1/
- B . https://<VCenter_IP>/rest/vxm/v1/
- C . https://<VxM_IP>/rest/vxm/v1/
- D . https://<VxM_IP>/API/vxm/v1/