VPLEX ndu pre-check command reports a time drift between directors and the Management Server. How must the NDU be performed?
- A . The NDU cannot be started. the time drift must be resolved.
- B . The NDU can be started using –skip-confirmations option.
- C . The NDU can be started. the time drift will be automatically fixed during upgrade.
- D . The NDU must be started using the –force option.
You are doing a code upgrade on a VPLEX. In which directory do you put the upgrade files in order to execute the code upgrade?
- A . /tmp/vfs
- B . /diags/collect-diagnostics-out
- C . /tmp/VPlexInstallPackages
- D . /tmp/diags
You are planning to perform a topology upgrade of VPLEX Local to VPLEX Metro.
What is the process you should follow to complete the upgrade successfully?
- A . 1. Upgrade the existing cluster
Run the I/O module upgrade script
Cable the WAN COM connections
Register the cluster
Configure the new cluster - B . 1. Run the I/O module upgrade script
Cable the WAN COM connections
Upgrade the existing cluster
Configure the new cluster
Register the cluster - C . 1. Upgrade the existing cluster
Register the cluster
Configure the new cluster
Run the I/O module upgrade script
Cable the WAN COM connections - D . 1. Cable the WAN COM connections
Run the I/O module upgrade script
Configure the new cluster
Register the cluster
Upgrade the cluster
What is the purpose of the I/O Module Upgrade Script?
- A . To manage the I/O module change during a Metro to Geo topology upgrade.
- B . To install the I/O load balancer module on the Management Server.
- C . To configure the GbE I/O modules when installing VPLEX Geo.
- D . To automate the installation of I/O modules and configuration of the directors.
Which command script must be executed when upgrading a small VPLEX to medium VPLEX?
- A . VPlexadmin add-engines
- B . director add
- C . VPlexadmin set
- D . VPlexadmin add-directors
You are preparing to migrate the topology of an installed VPLEX Local system. What is a supported upgrade path?
- A . Local to Geo to Global
- B . Local to Metro
- C . Local to Global
- D . Local to Metro to Geo
You created a synchronous consistency group, which contains two distributed volumes configured with the rule "set cluster-1-detaches".
What is the expected behavior of the virtual volumes in the event of a WAN-COM failure?
- A . cluster-2 is declared the winner after 5 seconds and I/O will continue at that cluster.
- B . I/O will continue at both clusters.
- C . I/O will be suspended at both clusters until the WAN-COM is repaired.
- D . cluster-1 is declared the winner after 5 seconds and I/O will continue at that cluster.
A new VPLEX cluster has been configured. However, you are unable to register any host initiators. After verifying that the host has been properly zoned to the VPLEX cluster, you still cannot register them. What is a possible cause?
- A . Front end ports have not been enabled.
- B . Back-end ports have not been enabled.
- C . Back-end arrays have not presented any LUNs.
- D . Storage View for host has not been created.
A customer is moving some VMAX devices under a VPLEX Local and is using PowerPath as multipath software.
What is the SCSI product ID assigned to VPLEX volumes?
- A . Invista
- B . VPLEX
- C . PowerPath
- D . VMAX
What components are required to create a storage view?
- A . One or more BE ports; One or more devices; Metadata volume and Logging Volumes
- B . One or more Host Initiators; One or more Virtual Volumes; One or more FE ports
- C . One or more FE ports; One or more BE ports; One or more Virtual Volumes
- D . One or more Host Initiators; One or more extents; One or more BE ports