DELL EMC D-PWF-DS-23 Dell PowerFlex Design 2023 Exam Online Training
DELL EMC D-PWF-DS-23 Online Training
The questions for D-PWF-DS-23 were last updated at Nov 26,2024.
- Exam Code: D-PWF-DS-23
- Exam Name: Dell PowerFlex Design 2023 Exam
- Certification Provider: DELL EMC
- Latest update: Nov 26,2024
A customer wants to generate a troubleshooting bundle of PowerFlex system activity.
Which three logs does the report generate? (Select 3)
- A . Cloudlink Center
- B . Dell PowerSwitch
- C . CloudIQ
- D . VMware ESXi
- E . Secure Connect Gateway
What is a primary benefit of using PowerFlex’s software-defined storage approach?
- A . Reduced need for manual intervention
- B . Enhanced hardware durability
- C . Increased data storage limits
- D . Flexibility and ease of management
How can PowerFlex integration be secured against unauthorized access from external networks?
- A . Implementing multi-factor authentication
- B . Disabling encryption protocols
- C . Opening all ports for unrestricted communication
- D . Implementing access control lists (ACLs)
Which of the following are considerations when aligning a PowerFlex solution to specific workload requirements? (Select all that apply)
- A . I/O requirements
- B . Data protection needs
- C . Cooling system capacity
- D . Power consumption
Which two actions can be performed for an existing Protection Domain? (Select 2)
- A . Add extra SDC.
- B . Evacuate all data.
- C . Add extra SDS.
- D . Change the PD name.
- E . Add new Volumes.
Which tools are recommended for troubleshooting performance issues in a PowerFlex cluster? (Select all that apply)
- A . PowerFlex Manager
- B . Performance monitoring utilities
- C . Third-party network analyzers
- D . System logs and error messages
An administrator is configuring an IOPS limit on a snapshot.
What is the minimum number of IOPS that they can set on the snapshot if the default value is not used?
- A . 1
- B . 2
- C . 5
- D . 11
What are the minimum and maximum volume sizes that can be created in the PowerFlex system?
- A . Minimum: 8 GB
Maximum: 1 PB - B . Minimum: 10 GB
Maximum: 1 PB - C . Minimum: 8 GB
Maximum: 10 PB - D . Minimum: 10 GB
Maximum: 10 PB
How does the configuration of Meta Data Managers impact PowerFlex’s performance?
- A . By accelerating hardware replacement cycles
- B . By enhancing metadata management and system efficiency
- C . By reducing the need for software updates
- D . By increasing the overall system security
Why is configuring Protection Domains in PowerFlex crucial?
- A . For defining network segments
- B . For managing different storage types
- C . For data redundancy and fault tolerance
- D . For tracking system usage statistics