DELL EMC D-PVM-DS-23 Dell PowerMax and VMAX Family Solutions Design 2023 Online Training
DELL EMC D-PVM-DS-23 Online Training
The questions for D-PVM-DS-23 were last updated at Nov 26,2024.
- Exam Code: D-PVM-DS-23
- Exam Name: Dell PowerMax and VMAX Family Solutions Design 2023
- Certification Provider: DELL EMC
- Latest update: Nov 26,2024
What action can an administrator perform on a PowerMax using VSI?
- A . View capacity utilization
- B . Manage re-syncing objects
- C . View replication sessions
- D . Manage High Availability
An architect is configuring BCSD to design SRDF/S between two new PowerMax arrays. The architect has completed the tasks for the local side of the solution, including RA Port Group, Replication Group, and site switch.
What is the correct order of steps the architect needs to take to complete the SRDF setup?
A storage administrator has mounted a snapshot of an existing datastore to the ESXi server and decided to keep its existing signature.
What action is prevented by keeping the existing signature?
- A . Increasing the datastore size
- B . Replicating the datastore
- C . Modifying the datastore configuration
- D . Restoring the datastore
What types of files are supported for import into Sizer?
- A . TTP, DCF, CSV, and configuration files
- B . TTP, CSV, and configuration files only
- C . BTP, DCF, CSV, and configuration files
- D . BTP, DCF, and configuration files only
In what format can loaded and mapped BCSD performance data be exported?
- A . DOC
- B . XML
- C . CSV
- D . PFD
A PowerMax customer has an existing Masking View for a large database environment. The parent Storage Group in this Masking View has three child Storage Groups with different Service Levels (SLs). The customer has been experiencing some database performance issues and wants to set the SL to Platinum for all the devices.
When the storage administrator attempts to set the SL on the parent Storage Group, they receive an error and the operation fails.
What is the cause of the error?
- A . There is insufficient capacity in the Storage Resource Pool
- B . A child Storage Group already has the Platinum SL applied
- C . SLs cannot be set on parent Storage Groups
- D . Platinum SL is not available for Cascaded Storage Groups
What needs to be created in BCSD to link multiple SRDF/A sessions?
- A . Composite Group
- B . Logical relationship
- C . Consistency Group
- D . MSC logical relationship
What action is required on a PowerMax thin device before it can be deleted?
- A . Unmap from front-end ports
- B . Remove from Storage Group
- C . Set to Write Disable
- D . Set to Not Ready
What action is required before performing a restore operation from a TimeFinder SnapVX snapshot?
- A . Copy the snapshot
- B . Remount the production volume
- C . Unmount the production volume
- D . Terminate the snapshot
When implementing SRDF/Metro with Array Witness, what is a requirement of the witness array?
- A . vApp running on a VMware ESXi server
- B . Empty RDF group from witness to source and target
- C . Two RDF groups with source and target devices
- D . Minimum of two witness arrays