Exam4Training

DELL EMC D-PST-MN-A-24 Dell PowerStore Maintenance Achievement Online Training

Question #1

How many nodes are in the base enclosure?

  • A . 2 nodes configured as Active-Standby
  • B . 1 node with duel connectivity
  • C . 1 node with high availability enabled
  • D . 2 nodes configured as Active-Active

Reveal Solution Hide Solution

Correct Answer: D
D

Explanation:

Reference: https://www.dell.com/support/manuals/pk/en/pkbsd1/powerstore-9000t/pwrstr-hwg/base-enclosure- component-overview?guid=guid-7914a554-6943-402e-bd38-3e893163657e&lang=en-us

Question #2

Which formats are available to list alerts?

  • A . Standard, NVP, CSV and JSON
  • B . Table, XLS, CSV and JSON
  • C . Table, NVP, CSV and XLS
  • D . Table, NVP, CSV and JSON

Reveal Solution Hide Solution

Correct Answer: D
D

Explanation:

https://downloads.dell.com/manuals/common/pwrstr-clirefg_en-us.pdf (output)

The default output format is table, as shown on the previous tab. You can also show events or alerts in name-value pair (NVP), comma-separated values (CSV), or JavaScript Object Notation (JSON). NVP format shows the full value of each field name and its value,

Question #3

Refer to the exhibit.

What is the result of the network configuration show for a Dell EMC PowerStore T node A management port?

  • A . VLAN 1 and VLAN 1501 pass tagged traffic
  • B . VLAN 1 passes tagged traffic, VLAN 1501 passes untagged traffic
  • C . VLAN 1 passes untagged traffic, VLAN 1501 passes tagged traffic
  • D . VLAN 1 and VLAN 1501 pass untagged traffic

Reveal Solution Hide Solution

Correct Answer: C
Question #4

Refer to the exhibit.

A Storage Administrator noticed a solid amber LED.

What does this mean?

  • A . Drive identification on
  • B . Drive rebuilding
  • C . Power up
  • D . Drive faulted

Reveal Solution Hide Solution

Correct Answer: D
D

Explanation:

Reference: https://www.dell.com/support/article/en-pk/sln321266/powerstore-understanding-led-colors-and-states-for-troubleshooting?lang=en

Question #5

How is a defective embedded module displayed in Dell EMC PowerStore Manager?

  • A . Orange with an empty state
  • B . Orange with a faulted state
  • C . Blue with a faulted state
  • D . Blue with an empty state

Reveal Solution Hide Solution

Correct Answer: B
Question #6

Which LED combination shows a connected and working node?

  • A . power LED: steady green fault LED: amber
  • B . power LED: blinking green fault LED: off
  • C . power LED: blinking green fault LED: blue
  • D . power: LED: steady green fault LED: off

Reveal Solution Hide Solution

Correct Answer: D
Question #7

What is the maximum number of base enclosures in a cluster when planning a Dell EMC PowerStore T installation?

  • A . 1
  • B . 2
  • C . 3
  • D . 4

Reveal Solution Hide Solution

Correct Answer: D
D

Explanation:

Reference: https://www.dellemc.com/en-us/collaterals/unauth/white-papers/products/storage/h18149-dell-emc-powerstore-platform-introduction.pdf

Question #8

What is the last step when adding a drive to a Dell EMC PowerStore system?

  • A . Verify the new drive is seen
  • B . Add the drive to the pool
  • C . Backup the keystore
  • D . Zero the drive

Reveal Solution Hide Solution

Correct Answer: A
Question #9

What is a step in configuring the ToR data switches for a Dell EMC PowerStore T?

  • A . Configure a port for the discovery laptop
  • B . Create VLANs for NAS servers
  • C . Create VLAN for vMotion networks
  • D . Configure ports for management on native VLAN

Reveal Solution Hide Solution

Correct Answer: A
Question #10

What describes the ICM and ICD networks?

  • A . Address type is dynamic and automatically reconfigured on discovery results
  • B . They are NOT encrypted
  • C . Address type is persistent throughout the life of the cluster and CANNOT to be modified
  • D . They are encrypted with IPsec

Reveal Solution Hide Solution

Correct Answer: D

Question #11

Through which network do external hosts connect to the cluster for data access?

  • A . Management
  • B . ICM
  • C . ICD
  • D . Storage

Reveal Solution Hide Solution

Correct Answer: D
D

Explanation:

https://topics-cdn.dell.com/pdf/pwrstr-hcg_en-us.pdf

Question #12

Refer to the exhibit.

What is indicated when the circled LED on the base enclosure is illuminated amber?

  • A . Base enclosure power-on
  • B . Cluster discovery state
  • C . Cluster service mode
  • D . Base enclosure fault

Reveal Solution Hide Solution

Correct Answer: D
D

Explanation:

https://www.dell.com/support/manuals/en-us/powerstore/pwrstr-hwg/base-enclosure-front-view?guid=guid-034671bd-ce1c-4c7f-a4d7-2679611fae51&lang=en-us

Question #13

Refer to the exhibit.

A Storage Administrator is troubleshooting a Dell EMC PowerStore T hardware issue. They observe that the base enclosure LED circled is blue.

What does this indicate?

  • A . Base enclosure hardware is operating normally
  • B . Base enclosure has a component hardware fault
  • C . Cluster has only a single appliance
  • D . Appliance has a node in service mode

Reveal Solution Hide Solution

Correct Answer: A
A

Explanation:

Reference: https://www.dell.com/support/manuals/pk/en/pkbsd1/powerstore-9000t/pwrstr-isg/embedded-module-leds?guid=guid-bc07892c-75cf-43b6-8f17-8a4c49001aeb&lang=en-us

Question #14

Which network is used for internal communication?

  • A . Intra-Cluster Data
  • B . Intra-Cluster Management
  • C . NAD Network
  • D . Inter-Node Network

Reveal Solution Hide Solution

Correct Answer: B
Question #15

DRAG DROP

Order the NDU operational steps.

Reveal Solution Hide Solution

Correct Answer:


Question #16

A Storage Administrator notices two fans in a Dell EMC PowerStore are faulted.

What describes the system behavior in this circumstance?

  • A . A five-minute timer starts upon the second fan fault and the system shuts down automatically after the timer expires
  • B . CPU clock speed is reduced by 50% to lower internal temperatures and the system continues normal operations
  • C . An increased fan speed signal is sent to the surviving fans and the system continues normal operations
  • D . Upon the second fan fault, all host I/O is terminated immediately and the PowerStore goes through the halt and vault process and shuts down

Reveal Solution Hide Solution

Correct Answer: A
Question #17

What does the command “svc_journalctl -f -g “st_io_monitor”” do?

  • A . Retrieves log messages from the specified error and watches for re-occurrence
  • B . Ignores log messages from the specified error and re-occurring errors
  • C . Rotates the log based on the specified error
  • D . Deletes all logs before the specified error

Reveal Solution Hide Solution

Correct Answer: B
Question #18

A Storage Administrator notices a Critical alert present in Dell EMC PowerStore Manager relating to data integrity.

What action within the alert details slide-out panel is helpful in troubleshooting the problem?

  • A . Select the Gather Support Materials from Service and Support
  • B . Access the Repair Flow link to schedule a support engagement
  • C . Examine Notifications to obtain a list of corrective actions
  • D . Re-engage support through previous listed Related Events

Reveal Solution Hide Solution

Correct Answer: C
Question #19

Which option is used when running the journalctl command to query log messages regardless of capitalization?

  • A . option –casesensitive=YES/NO
  • B . option -quotes
  • C . option -ignorecase
  • D . option –casesensitive=TRUE/FALSE

Reveal Solution Hide Solution

Correct Answer: C
Question #20

Which Dell EMC PowerStore network uses an appliance backplane?

  • A . ICD
  • B . MPIO
  • C . Inter-node
  • D . Inter-cluster management

Reveal Solution Hide Solution

Correct Answer: C
C

Explanation:

Reference: https://blocksandfiles.com/2020/05/05/dell-emc-powerstore-midrange-array-launch-analysis/

Question #21

What describes the power requirements for Dell EMC PowerStore?

  • A . Lower model numbered systems require less AC line current than higher model numbered systems
  • B . T models require less total power than X models
  • C . X models require less total power than T models
  • D . Lower model numbered systems require less input voltage (VAC) than higher model numbered systems

Reveal Solution Hide Solution

Correct Answer: A
A

Explanation:

Maximum input power 240 VAC ± 10%, single phase For 100-120V, a customer-supplied step-up transformer is required AC Line Current (operating maximum at 200 VAC) 8.1 A 8.1 A 9.0 A 9.0 A 9.3 A 10.4 A https://www.dell.com/support/manuals/en-us/powerstore-5000/pwrstr-plang/power-requirements-for-powerstore-x-model-and-powerstore-t-model?guid=guid-21e142df-e22c-4bbc-8978-7c6124753654&lang=en-us

Reference: https://www.dell.com/support/manuals/pk/en/pkbsd1/powerstore/pwrstr-plang/power-requirements?guid=guid-21e142df-e22c-4bbc-8978-7c6124753654&lang=en-us

Question #22

What Dell EMC PowerStore reference provides the user access to the entire set of product documentation, knowledge base articles, and product warranty and contracts?

  • A . SolVe Desktop and Online
  • B . Dell EMC Online Support
  • C . Dell EMC PowerStore Series Product Page
  • D . PowerStore Manager in App (Offline) Help

Reveal Solution Hide Solution

Correct Answer: B
Question #23

DRAG DROP

Match the base enclosure SAS ports in column A to their corresponding expansion LCC ports in column B; when connecting a PowerStore base enclosure to a single expansion enclosure.

Reveal Solution Hide Solution

Correct Answer:


Question #24

What describes Dell EMC PowerStore X power down?

  • A . PowerStore X node, appliance, or cluster power down is done entirely with vCenter server commands
  • B . Powering down a PowerStore X node, appliance, or cluster is done in the same manner as a PowerStore T
  • C . PowerStore X node, appliance, or cluster power down utilizes the VSi plugin to perform the needed vCenter server operations
  • D . Powering down a PowerStore X node, appliance, or cluster requires additional vCenter server commands

Reveal Solution Hide Solution

Correct Answer: A
Question #25

DRAG DROP

When connecting a PowerStore base enclosure to 2 expansion enclosures, match the base SAS ports in column A to their corresponding expansion LCC ports in column B.

Reveal Solution Hide Solution

Correct Answer:

Explanation:

B B —> B A

A A —> B B

A B —> A A

B A —> A B


Question #26

While on-site installing a Dell EMC PowerStore system, the node A and embedded module fault LEDs are alternating blue and amber (blue for 3 seconds).

What does this indicate?

  • A . The system is booting
  • B . Nodes are in service mode
  • C . The system is not initialized
  • D . Nodes are in degraded mode

Reveal Solution Hide Solution

Correct Answer: C
Question #27

From where can a data collection be initiated within Dell EMC PowerStore Manager?

  • A . Appliance, node, and storage resource
  • B . Cluster, appliance, and alerts
  • C . Cluster, appliance, and event log
  • D . Node, storage resource, and alerts

Reveal Solution Hide Solution

Correct Answer: B
B

Explanation:

Collecting Support Materials can be initiated several ways from PowerStore Manager. Data Collections can be started at the Cluster, Appliance, Storage Resource, and Alerts level.

Question #28

What safety equipment is critical to have on hand to avoid equipment failure before replacing any components in a Dell EMC PowerStore array?

  • A . Maintenance Kit
  • B . ESD Kit
  • C . Stabilization Kit
  • D . Rail Kit

Reveal Solution Hide Solution

Correct Answer: B
Question #29

How can the PUHC health check results be viewed?

  • A . By accessing the Swagger UI
  • B . From syslog server
  • C . In Details of Appliances and Nodes
  • D . From management DB

Reveal Solution Hide Solution

Correct Answer: A
Question #30

When a Dell EMC PowerStore node powers up in service mode, what are the commands and sequence used from the appliance SSH client to restore the node back to normal?

  • A . svc_rescue_state clear
    svc_node reboot
  • B . svc_node restart
    svc_rescue_state start
  • C . svc_rescue_state normal
    svc_node start
  • D . svc_node shutdown
    svc_rescue_state clear

Reveal Solution Hide Solution

Correct Answer: A

Question #31

A Storage Administrator needs to address specific fixes within their Dell EMC PowerStore system.

Which NDU software upgrade option is used for this situation?

  • A . Hotfixes
  • B . vCenter
  • C . Drive firmware
  • D . Software releases

Reveal Solution Hide Solution

Correct Answer: A
Question #32

What is the default log collection schedule?

  • A . Weekly
  • B . As scheduled during install
  • C . Hourly
  • D . Daily

Reveal Solution Hide Solution

Correct Answer: B
Question #33

Refer to the exhibit.

What is indicated when the circled LED on an expansion enclosure is illuminated amber?

  • A . Expansion enclosure faulted
  • B . SAS bus link up
  • C . SAS bus link down
  • D . Expansion enclosure power-on

Reveal Solution Hide Solution

Correct Answer: A
Question #34

Which component is only replaceable by qualified personnel?

  • A . Battery backup unit
  • B . Embedded I/O module
  • C . Memory module
  • D . 4-Port mezzanine card

Reveal Solution Hide Solution

Correct Answer: C
Question #35

Refer to the exhibit.

What type of cable is used for the ToR switch configuration shown for the S5248F-ON switches?

  • A . 10 GigE Cat 6 Ethernet RJ-45
  • B . 25 GigE Twinax
  • C . 100 GigE QSFP28
  • D . 10 GigE SFP optical cable

Reveal Solution Hide Solution

Correct Answer: C
C

Explanation:

Reference: https://www.dellemc.com/resources/en-us/asset/technical-guides-support-information/solutions/h18242-ready-stack-powerstore-dg.pdf?dgc=SM&cid=170850&lid=spr3492306896&linkId=93885839

Question #36

What is an alternative way to collect logs instead of using the Dell EMC PowerStore manager GUI?

  • A . Data Collect using Service Container
  • B . USB stick inserted into the system
  • C . Data Collect using vCenter
  • D . Discovery Utility

Reveal Solution Hide Solution

Correct Answer: A
Question #37

What are the recommended number of network switches in a Dell EMC PowerStore T environment?

  • A . 1
  • B . 2
  • C . 3
  • D . 4

Reveal Solution Hide Solution

Correct Answer: C
C

Explanation:

Reference: https://www.dell.com/support/manuals/pk/en/pkbsd1/powerstore-9000t/pwrstr-ntwk-plang/powerstore-t-model-appliance-networks?guid=guid-97a3e988-c1bc-4f51-a445-3af23f19da1b&lang=en-us

Question #38

A Storage Administrator has an existing single appliance Dell EMC PowerStore 3000T cluster. An additional PowerStore 9000T has been purchased to add into the existing cluster.

How does the administrator proceed?

  • A . Additional VLTi links on the ToR switching must be configured for the 9000T to support the increased inter-switch network load
  • B . Add the new 9000T appliance into the cluster per the procedure; mixed models of the same type are supported
  • C . Remove two of the four NVMe NVRAM drives from the 9000T the caching configuration of all clustered appliances must match
  • D . The new appliance cannot be added to the cluster; appliance model and type must match when clustering appliances together

Reveal Solution Hide Solution

Correct Answer: A
Question #39

What describes the SAS cabling when adding an expansion enclosure to a Dell EMC PowerStore, for each node and expansion enclosure side?

  • A . SAS cabling goes from existing A ports to new ports. At the last enclosure, SAS cabling returns from the A ports to the originating node’s B ports
  • B . SAS cabling goes from existing A ports to new ports. At the last enclosure, SAS cabling returns from the A ports to the alternate node’s ports
  • C . SAS cabling goes from existing ports to new A ports. At the last enclosure, SAS cabling returns from the ports to the alternate node’s A ports
  • D . SAS cabling goes from existing ports to new A ports. At the last enclosure, SAS cabling returns from the ports to the originating node’s A ports

Reveal Solution Hide Solution

Correct Answer: B
Question #40

During an emergency event an ESD-Kit is unavailable for FRU replacement.

How can the work proceed?

  • A . If FRU does not contain ESD-Kit, continue without it
  • B . Order “Emergency ESD-Kit” ASAP
  • C . Follow precautions described in the “Emergency Procedure”
  • D . Use package material to build “provisional ESD-Kit”

Reveal Solution Hide Solution

Correct Answer: C

Question #41

A Storage Administrator has just installed PSTCLI on a Linux client. The administrator is unfamiliar with the PSTCLI command list.

How can the administrator get a list of all PSTCLI commands from the cli> prompt?

  • A . Type the <Ctrl>+keys together
  • B . Press the <Tab> key
  • C . Use the show all command
  • D . Use the help all command

Reveal Solution Hide Solution

Correct Answer: D
D

Explanation:

https://dl.dell.com/topicspdf/pwrstr-cliug_en-us.pdf

Question #42

A Storage Administrator needs to add drives to a base enclosure of a Dell EMC PowerStore 7000T system. The system currently contains 10 750 GB NVMe SCM drives.

Which drive configuration maximizes the base enclosure capacity?

  • A . 11 15360 GB NVMe SSD drives in slots 10 – 20
  • B . 13 15360 GB NVMe SSD drives in slots 10 – 22
  • C . 11 750 GB NVMe SCM drives in slots 10 – 20
  • D . 13 750 GB NVMe SCM drives in slots 10 – 22

Reveal Solution Hide Solution

Correct Answer: C
Question #43

What is the maximum number of expansion enclosures that a single Dell EMC PowerStore appliance supports?

  • A . 2
  • B . 3
  • C . 4
  • D . 6

Reveal Solution Hide Solution

Correct Answer: B
B

Explanation:

Reference: https://www.dellemc.com/resources/en-us/asset/data-sheets/products/storage/h18143-dell-emc- powerstore-family-spec-sheet.pdf (1)

Question #44

What describes Dell EMC PowerStore X front-end cabling?

  • A . Uses internal VMware virtual switching and does not require a management network
  • B . Storage and management use the same LACP bonded cable connection
  • C . Uses VLTi data switch interconnectivity to support vMotion networks
  • D . Management and discovery use the same cables and connections as storage

Reveal Solution Hide Solution

Correct Answer: D
D

Explanation:

"For PowerStore T model appliances, the individual ports within the system bond could be running in active/active mode or active/passive mode. This state depends on whether Link Aggregation Control Protocol (LACP) has been configured on the network switches. To ensure best resiliency and network performance, it is recommended to enable LACP on the network. For more information about configuring LACP for a PowerStore T model appliance, see the document PowerStore Guide for PowerStore T Models on the PowerStore Info Hub. For PowerStore X model appliances, there is no system bond and no LACP configuration is needed because the link aggregation and failover is handled by the virtual switches within the VMware hypervisor. "

Question #45

A Storage Administrator wants to upgrade a two appliance Dell EMC PowerStore cluster.

Which Commit options need to be chosen to have all appliances upgraded in the last step?

  • A . Appliance, Cluster
  • B . Appliance, Appliance
  • C . Cluster, Appliance
  • D . Cluster, Cluster

Reveal Solution Hide Solution

Correct Answer: A
A

Explanation:

Appliance

– Deletes old docker images and packages

– Moves to next appliance

Cluster

– All appliances upgraded

– Marks new version as current

– Deletes old package name in GUI

Question #46

What method is used to power down a Dell EMC PowerStore system in a true emergency situation?

  • A . Run svc_node shutdown
  • B . Power Down Cluster in PowerStore GUI
  • C . Turn off the cabinet switches
  • D . Remove base enclosure power cables

Reveal Solution Hide Solution

Correct Answer: C
C

Explanation:

Reference: https://www.dell.com/support/manuals/pk/en/pkbsd1/powerstore-1000/pwrstr-isg/power-control-procedure-considerations?guid=guid-4352c94e-0ae7-4a2e-8593-9ae135bb9e34&lang=en-us

Question #47

How is a service laptop IP configured to connect to the Service LAN port of a Dell EMC PowerStore node?

  • A . Static IP: 128.221.1.249 and netmask: 255.255.255.0
  • B . Obtain IP address from DHCP on PowerStore
  • C . Static IP: 169.254.1.249 and netmask: 255.0.0.0
  • D . Leave IP address and netmask unconfigured

Reveal Solution Hide Solution

Correct Answer: A
Question #48

Which reference source provides service information and FRU procedures for the Dell EMC PowerStore?

  • A . SolVe Tool
  • B . Dell EMC PowerStore Product Page
  • C . PowerStore Manager help
  • D . DELL EMC Online Support

Reveal Solution Hide Solution

Correct Answer: A
Question #49

A Storage Administrator ran a PSTCLI command on a Linux host. The error " -bash: pstcli: command not found" appears.

How is the problem resolved?

  • A . Add the installation directory to the PATH variable on shell initialization file
  • B . Install in default directory /opt/dellemc/pstcli-version/bin/
  • C . Add /opt/dellemc/pstcli/bin/in PSTCLI.sh
  • D . Run rpm -ihv pstcli to reinstall the PSTCLI software on the Linux host

Reveal Solution Hide Solution

Correct Answer: A
Question #50

A Storage Administrator is adding an appliance into an existing Dell EMC PowerStore T cluster.

What is different about the management network configuration for the new appliance compared to configuring an initial appliance for the cluster?

  • A . All the needed management IP addresses for the new appliance must be pre-configured on the cluster
  • B . Additional appliance does not require a cluster management IP address
  • C . Additional appliance inherits all its management IPs from the existing appliance
  • D . All the needed management IP addresses for the new appliance are auto-generated by the cluster

Reveal Solution Hide Solution

Correct Answer: A
A

Explanation:

Each appliance must have Management and Storage networks configured. Management networks connect the cluster to management services such as DNS, NTP, and vCenter. The management network also enables external clients to access the cluster. The Storage network connects the cluster to an existing storage network or establishes a new network within the cluster. It also enables external clients to access the storage in the cluster. Both the Management and Storage networks require at least three IP addresses

Question #51

Which number in the code-naming schema represents a beta distribution?

  • A . 8
  • B . 6
  • C . 4
  • D . 5

Reveal Solution Hide Solution

Correct Answer: C
Question #52

Refer to the exhibit.

A Storage Administrator noticed a drive LED blinking blue.

What does this indicate?

  • A . Is faulted
  • B . Access activity
  • C . Power up
  • D . Identification is on

Reveal Solution Hide Solution

Correct Answer: B
Question #53

A Storage Administrator needs to connect through SSH to run svc commands.

How is the SSH session configured?

  • A . Appliance IP address using port 22
  • B . NAS server IP address using port 26
  • C . NAS server IP address using port 22
  • D . Appliance IP address using port 26

Reveal Solution Hide Solution

Correct Answer: A
Question #54

What is the result of setting a VLAN ID of 0 on a network when running ICW for Dell EMC PowerStore?

  • A . Network will pass tagged traffic
  • B . Static route is set
  • C . Network will pass untagged traffic
  • D . Default route is set

Reveal Solution Hide Solution

Correct Answer: C
C

Explanation:

Reference: https://topics-cdn.dell.com/pdf/pwrstr-ntwk-plang_en-us.pdf (22)

Question #55

DRAG DROP

Match the correct non-disruptive upgrade process step (answer column) with the correct sub-step (match column).

Reveal Solution Hide Solution

Correct Answer:

Explanation:

Upload => receives the package

Health check=> run in parallel on all appliances

Upgrade=> Starts with the master appliance

Commit => delete and mark the new version as current

upvoted 2 times


Question #56

Which component is an FRU?

  • A . DIMMs
  • B . Embedded IO Module
  • C . Nodes
  • D . Battery Backup Unit

Reveal Solution Hide Solution

Correct Answer: A
Question #57

What does the output of the PSTCLI command “nas_server show” display from a Dell EMC PowerStore T?

  • A . If NAS servers are present if they are either NFS or Licensed
  • B . Memory utilization and thread count for NFS NAS servers
  • C . If NAS servers are present and if they are either Started or Degraded
  • D . SIDs of SMB NAS servers joined to the AD Domain

Reveal Solution Hide Solution

Correct Answer: C
Question #58

Which account credentials are needed to run diagnostic commands?

  • A . root
  • B . service
  • C . console
  • D . admin

Reveal Solution Hide Solution

Correct Answer: B
Question #59

For what is the “svc_container_mgmt status CP” command used?

  • A . Clears the Control Path audit log
  • B . Resets the Data Path root access
  • C . Checks the status of the Control Path
  • D . Checks the status of the Data Path

Reveal Solution Hide Solution

Correct Answer: C
C

Explanation:

Reference: http://webcache.googleusercontent.com/search?q=cache:ZhvW4-xt2TEJ:dunmer.net/guides/powerstore-implementation/PowerStore%252BBasic%252BTroubleshooting%252BExternal%252B-%252BParticipant%252BGuide.pdf+&cd=3&hl=en&ct=clnk&gl=pk&client=ubuntu

Question #60

DRAG DROP

Correctly order the steps of the embedded module replacement procedure.

Reveal Solution Hide Solution

Correct Answer:

Explanation:

Step 1: Power down the node

Step 2: Label and disconnect all cables attached to the embedded module

Step 3: Push the orange tab to release the lever of the embedded module

Step 4: Remote the 4-port card from the old embedded module and install it into the new embedded module

Step 5: Align the embedded module with the empty slot and carefully push it into the slot

https://dl.dell.com/topicspdf/pwrstr-isg_en-us.pdf


Exit mobile version