DELL EMC D-PSC-MN-01 Dell PowerScale Maintenance Online Training
DELL EMC D-PSC-MN-01 Online Training
The questions for D-PSC-MN-01 were last updated at Mar 06,2025.
- Exam Code: D-PSC-MN-01
- Exam Name: Dell PowerScale Maintenance
- Certification Provider: DELL EMC
- Latest update: Mar 06,2025
A platform engineer must replace a failed chassis on a Dell PowerScale Gen6 cluster.
What must the engineer do after powering off the nodes?
- A . Remove the drive sleds, label them for identification, and place the drive sleds In the newly installed chassis.
- B . Remove the drive sleds and motherboard and transfer them to the new chassis.
- C . Remove the drives and compute modules and reimage each drive before installing them in the chassis.
- D . Remove the drives, install the chassis, and place the drives in the new chassis.
Dell Technical Support has requested a part be sent back to Dell Logistics to be studied.
Which process or document musi be completed before sending the part back?
- A . WWFA
- B . DTFA
- C . DMR
- D . CDMR
What must be enabled in SMB to ensure nondisruptive upgrades?
- A . SMB multichannel
- B . SMB encryption
- C . SMB direct
- D . SMB continuous availability
Windows clients cannot connect using the fully qualified domain name when testing the connectivity of a newly created cluster.
What connection test identifies the problem?
- A . DNS
- B . NFS Mount
- C . Mapping a Windows drive
- D . WebUI using IP address
An engineer runs ini_reformat_node command.
What are they attempting to do?
- A . Reformat the mirrored FEC data.
- B . Reformat a node quickly to repurpose a node.
- C . Reformat the mirrored journals.
- D . Reformat a node to securely erase all data.
An existing PowerScale cluster consists of four A300 and three F600 nodes.
What is the minimum number of nodes an engineer can add to expand both node pools?
- A . txA300 2xF600
- B . 2xA300 2xF600
- C . 3xF600 4xA300
- D . 2xA300 1x F600
What type of upgrade on a Dell PowerScale cluster requires the least amount of time?
- A . Simultaneous
- B . Parallel
- C . Rolling
- D . Automatic
Refer to the exhibit.
An engineer replaced the drive in C1. They run the isi devices drive list command and obtain the output that is shown.
What action must the engineer take?
- A . Run the 1 = 1 devices drive add c1 command.
- B . Run the isi devices drive format C1 command.
- C . Contact Dell support.
- D . Update the drive firmware.
What is the isi diagnostics gather command used for?
- A . Diagnose the CPU.
- B . Diagnose the TPM
- C . Gather performance data.
- D . Gather cluster logs
Which model is a part of the Isilon Gen6 platform?
- A . F600
- B . F810
- C . F900
- D . F200