DELL EMC D-PSC-DY-23 Dell PowerScale Deploy 2023 Online Training
DELL EMC D-PSC-DY-23 Online Training
The questions for D-PSC-DY-23 were last updated at Nov 26,2024.
- Exam Code: D-PSC-DY-23
- Exam Name: Dell PowerScale Deploy 2023
- Certification Provider: DELL EMC
- Latest update: Nov 26,2024
You have followed the configuration document and set up a new cluster in Compliance mode. You meet with the customer to plan directory layout and configuration requirements.
What directory types will you be able to consider for this cluster?
- A . Non-WORM and Compliance Smart Lock directories only
- B . Non-WORM, Enterprise Smart Lock, and Compliance Smart Lock directories
- C . Compliance Smart Lock directories only
- D . Enterprise Smart Lock and Compliance Smart Lock directories only
A new file pool policy is configured on a Dell PowerScale cluster to move all media files to A200 nodes. The previously written media files are located on H500 nodes.
What does the administrator need to run to apply the new file pool policy on the old media files?
- A . SetProtectPlus job
- B . MediaScan job
- C . SmartPools job
- D . MultiScan job
Which type of information does the Isilon isi statistics command provide?
- A . Job engine and critical alerts
- B . Drive statistics and hardware condition
- C . Protocol and node statistics
- D . Drive replacement and node management
Which SSH Multi-Factor Authentication (MFA) service is supported by OneFS 8.2.0?
- A . Duo
- B . RSA
- C . Okta
- D . Yubico
A Dell EMC Isilon customer’s existing cluster has Gen 5 nodes. They are using both 1 GbE and 10 GbE connectivity options. The 1 GbE is configured with the management network.
The 10 GbE is connected to the data and replication network. The customer is planning to add new Gen 6 nodes to their cluster. They want to know the available options for front-end connectivity on Gen 6 nodes.
Which information should be provided to the customer?
- A . 1 GbE and 10 GbE front-end Ethernet options are available in Gen 5 nodes
10 GbE and 40 GbE front-end Ethernet options are only available in Gen 6 nodes - B . 1 GbE, 10 GbE, and 40 GbE front-end Ethernet options are only available in Gen 6 nodes
- C . 1 GbE, 10 GbE, and 40 GbE front-end Ethernet options are available on both Gen 5 and Gen 6 nodes
- D . 10 GbE and 40 GbE front-end Ethernet options are only available in Gen 5 nodes
1 GbE and 10 GbE front-end Ethernet options are available in Gen 6 nodes
How many Isilon Job Engine v2.0 components will be present on a single node?
- A . One director
- B . Two managers per job
- C . Two workers per task
- D . Three coordinators
What can be determined when auditing is enabled on an EMC Isilon cluster?
- A . Who made the change When the change was made If the change can be undone
- B . When the change was made If the change can be undone If proper ITIL process was followed
- C . Who observed the change When the change was made If the change can be undone
- D . When the change was planned If the change can be undone If proper change control was followed
Which basic administration task can be performed using the front panel of an Isilon node?
- A . Adding the node to a cluster
- B . Creating a Smart Connect zone
- C . Configuring an additional interface
- D . Creating an access zone
What must be done to configure cluster name resolution for SmartConnect?
- A . Create the SSIP, add the DNS delegation, configure the subnet, and configure the node pool
- B . Create a host A record, create an NS record, configure the subnet, and configure the pool
- C . Create the SSIP, create an NS record, configure the subnet, and configure IPv6 and IPv4
- D . Create a host A record, add the DNS delegation, configure the subnet, and configure IPv4
What is the recommended method when cabling an Isilon cluster with dual InfiniBand switches?
- A . All int-a InfiniBand switch ports should be connected to one switch and all int-b ports should be cabled to the second switch.
- B . All internal switch ports on odd-numbered nodes should be attached to switch one and all even numbered nodes should be cabled to switch two.
- C . All int-a switch ports should be cabled to the top row of switch ports on switch one and all int-b ports should be cabled to the bottom row of ports of switch one. Once switch one is full, continue cabling on switch two.
- D . It does not matter which switch ports are used. Any internal switch port can be cabled to either of the InfiniBand switches.