A technician wants to remotely log in to a server but finds that the IDRAC virtual Console feature Is not available. Use the simulator to explore the system.
What Is the cause of this Issue? Note: It is necessary to dose (x) the simulator window before you can select a response to this question.
- A . The Virtual Console is disabled
- B . Operating system not installed on remote server
- C . The server has been powered down
- D . There are more than the maximum number of active sessions
What is a requirement to operate GPUs in a Dell EMC PowerEdge R740 server?
- A . All GPU cards must be installed at the same time
- B . All GPU cards must be of the same type but can be a different model
- C . All GPU cards must be of the same type and model
- D . All GPU cards must be installed on the same riser card
What happens when the Hardware Root of Trust fails to validate the BIOS?
- A . Boot Guard switches over to the backup BIOS and logs a warning in the system event log.
- B . Automated BIOS Recovery process recovers the BIOS from the DUP saved in the control panel.
- C . The server continues running and logs a critical error in the system event log.
- D . The server shuts down and logs a critical error in the system event log.
A technician receives a new server with five drives.
They need to configure the drives based on the following requirements received from the administrator:
– Drive 0 as a single disk with no RAID
– Drives 1-3 as a RAID 5 with drive 4 as a hot spare just for this newly created RAID 5
The administrator plans to add more disks as separate RAID arrays at a later date but only wants drive 4 to be available for this first RAID 5 set.
How should the technician configure the drives?
- A . Set drive 0 to Ready; set drives 1-3 as RAID 5; set drive 4 as a Global Hot Spare
- B . Set drive 0 to Non-Raid; set drives 1-3 as RAID 5; set drive 4 as a Dedicated Hot Spare
- C . Set drive 0 to Non-Raid; set drives 1-3 as RAID 5; set drive 4 as a Global Hot Spare
- D . Set drive 0 to Ready; set drives 1-3 as RAID 5; set drive 4 as a Dedicated Hot Spare
A technician must update the firmware on a savor, but has no network connectivity.
What can the technician use to update the BIOS and iDRAC/ lifecycle Controller firmware?
- A . OpenManage Server administrator DVD
- B . ftp dell.com
- C . NFS share
- D . USB key with Dell Update Package
A Dell EMC PowerEdge server has been updated with an LCC and iDRAC DUP to the latest firmware when performing a firmware rollback?
- A . The LCC can be rolled back; the iDRAC cannot be rolled back
- B . The iDRAC cannot be rolled back and the LCC cannot be rolled back
- C . The iDRAC can be rolled back; the LCC cannot be rolled back
- D . Both the iDRAC and the LCC can be rolled back
A technician wants to configure the iDRAC on a new server using the iDRAC Quick Sync 2 feature.
What is required to use this feature?
- A . OpenManage Mobile App installed on an Android or iOS device
- B . OpenManage Mobile App installed on a laptop
- C . Quick Sync enabled bezel
- D . iDRAC Enterprise license
Which is responsible for controlling the NVMe disks, when using a Paddle Card in a PowerEdge 15G server?
- A . S150
- B . HBA355
- C . H745
A technician needs to configure a server to allow the OS to manipulate processor frequencies for higher power efficiency.
Which setting can they enable to achieve this?
- A . Logical Processing
- B . Performance per Watt (DAPC)
- C . Adjacent Cache Line Prefetch
- D . Performance per Watt (OS)
How can a system administrator compare the currently installed hardware to the original system configuration?
- A . Pull a SupportAssist Collection Comparison Report
- B . Restore the original System Profile
- C . View Factory Shipped Inventory
- D . Export a Tech Support Report
A server has six memory modules attached to each CPU Memory Optimizer mode is configured. The user now wants to have maximum protection for the memory but cannot afford to lose any memory space.
What should the technician install/configure?
- A . No additional memory
Switch on Single Rank Spare Mode - B . No additional memory
Switch to memory Mirroring - C . Six additional memory modules matching the original
Switch on Single Rank Spare Mode - D . Six additional memory modules matching the original
Switch to Memory Mirroring
Where is the LCD panel located on a Dell PowerEdge 16G server?
- A . An add-on Server Bezel
- B . Rear of the server
- C . Left control panel
- D . Right control panel
A technician is trying to troubleshoot a server that constantly keeps raising and lowering the RPMs of the fans.
The technician investigates and finds the following:
– No errors are displayed
– No obvious log entries exist concerning temperatures
– Server cover is installed and secured
– No expansion cards are installed
What would be the quickest action plan that the technician could attempt to try to fix the issue with the fans?
- A . Replace all the fans
- B . Upload the latest iDRAC firmware
- C . Replace the fans one at a time until the faulty fan is identified
- D . Adjust the Multi Vector Cooling values
A technician installs a PCIe card into a server, but the card does not appear in the OS. The server does not have an LCD to display errors, but a light is flashing on the front of the server.
What actions can the technician take to troubleshoot the issue?
- A . Initiate Hardware Stress Test from iDRAC GUI
Check PCIe Bus Log for errors - B . Run Hardware Diagnostics from Lifecycle Controller
Review the Lifecycle Controller log for errors - C . Run Hardware Diagnostics from Lifecycle Controller
Initiate Hardware Stress Test from iDRAC GUI - D . Review the Lifecycle Controller log for errors
Check PCIe Bus Log for errors
What is the minimum number of components, beside the system board, required to POST?
- A . 1 PSU, 1 DIMM, and 1 CPU only
- B . 1 PSU, 1 CPU, 1 DIMM, and PERC SAS controller
- C . 1 PSU and 1 CPU only
- D . PSUs, CPUs, and DIMMs as configured in BIOS
Which export type in iDRAC restores a Server Configuration Profile to a known baseline?
- A . Advanced
- B . Replacement
- C . Basic
- D . Clone
A technician is setting up SNMP Trap Alerts on a 14G servers.
After specifying the trap destination address, what should be the next step?
- A . Enable the SMNP Client service on the iDRAC
- B . Include the server OS IP address in the destination systems authentication script
- C . Enable the SMNP services in the server operating system of the sending server
- D . Send an SNMP trap test to the destination system
A technician is installing Windows Server 2016 on a server with RAID 1 and RAID 5 virtual disks.
How should they configure the server and deploy the OS?
- A . Go to system setup to configure both virtual disks
Select the Deploy OS option in the system setup utility - B . Go to Settings in the Lifecycle Controller
Configure both virtual disks using the guided OS installation method - C . Create two virtual disks using the iDRAC UI
Access the Lifecycle Controller
Go to OS deployment using ‘Deploy OS’ - D . Go to the RAID Configuration menu in the Lifecycle Controller
Create both virtual disks
Go to OS deployment using ‘Deploy OS’
What is the maximum number of CPU cores that can be configured in a Dell EMC PowerEdge R6525 server?
- A . 56
- B . 64
- C . 112
- D . 128
A Dell EMC PowerEdge server logs the following CPU Machine Check error: CPU1 IERR.
What action might be required to solve the alert?
- A . Clear logs
- B . Update the Intel driver
- C . Swap the PERC controller
- D . Reseat the IDSDM
A technician needs to perform a RAID controller firmware update from within the Operating System. The server runs Red Hat Enterprise Linux and is configured with an iDRAC basic license.
Which three steps should the technician take to complete this task? (Choose three.)
- A . R estart the server and press F10 t o start the firmware update process
- B . After firmware update, run fsck command on the virtual disks
- C . Obtain the latest firmware update for the RAID controller
- D . Run racadm fwupdate command from a management station
- E . Open a command shell and execute the firmware package
- F . After the firmware update, restart the server
A technician must create a RAID array that uses striping with double parity.
Which RAID level must be used?
- A . RAID 5
- B . RAID 10
- C . RAID 50
- D . RAID 6
A technician installs eight servers into a fully operational rack with top of rack switch Each server has a quad 1Gb NIC and redundant power supplies. The company uses iDRAC in shared LOM mode with LOM1 as the selected NIC.
What should the technician do to verify iDRAC connectivity on each server?
- A . iDRAC Datacenter license is installed.
- B . Ethernet port LOM1 is cabled and the link light is green
- C . iDRAC dedicated NIC port is cabled and the link light is green
- D . iDRAC Enterprise license is installed
Which Dell PowerEdge 16G server has the highest GPU density to run workloads like HPC, AI, DB Analytics, and VDI?
- A . XR4520c
- B . XR7620
- C . XE8545
- D . XE8640
A technician in Portland, Oregon has been asked to update the firmware on a server in Omaha, Nebraska. They will use an NFS server also located in Nebraska for serving patches that have been vetted by their security teams.
What two pieces of information does the technician need in order to access the NFS patch server from the Lifecycle Controller or iDRAC? (Choose two.)
- A . Username and password
- B . CHAP authentication credentials
- C . IP address or hostname
- D . Share name
A remote technician needs to update the iDRAC with Lifecycle Controller firmware using the iDRAC GUI. They have downloaded the iDRAC firmware to the management station and connected to the iDRAC GUI.
What step is required to complete this task?
- A . Reboot the server to apply the update
- B . Boot the server into F10
- C . Start the Lifecycle Controller and select Firmware Update
- D . Use the Firmware Update page to upload and install the firmware
A technician is investigating a server that is reporting that the Lifecycle Controller is disabled during the power-on procedure.
After checking that the system is displaying no other errors, how can the technician re-enable the Lifecycle Controller?
- A . Access the System Setup utility
Select iDRAC Settings and then select Lifecycle Controller
Check the Enable option, save, and reboot the server - B . Enter the iDRAC GUI
Select iDRAC Settings > Lifecycle Controller
Check the Enable option and then power cycle the server - C . Reboot the server
Press F10 during power up and access the Lifecycle Controller GUI
Select Power On Messages, select Enable, and reboot the server - D . Reboot the server and press Ctrl+L during the power on procedure
At the prompt type “LCC-enable”
Select save and reboot the server
A technician wants to install a new version of OMSA onto a server that already has an existing version of OMSA.
What is required for this new installation?
- A . iSM must also be installed on the managed server
- B . iDRAC firmware needs to be at version 5.0 or higher
- C . Existing OMSA version must be disabled in Services
- D . Existing OMSA must be uninstalled before the new version is installed
Eight new servers have arrived at a datacenter. All use static IP addresses for iDRAC. The technician needs to enable these servers to contact the DHCP server on the network to obtain new IP addresses.
What method can the technician use to quickly switch to DHCP?
- A . Reboot each server to enable DHCP default settings
- B . Boot into CTRL+S and change iDRAC settings to DHCP
- C . Use the LCD panel to input a new IP address
- D . Log in to the iDRAC and enable DHCP
Which front disk chassis option is available in a Dell EMC PowerEdge R740 server?
- A . 4x 3.5" drives
- B . 8x 3.5" drives
- C . 12x 2.5" drives
- D . 24x 2.5" drives
You have been tasked with configuring a Dell EMC PowerEdge server to be a file server. The server operating system has been installed and there are 8 x 1TB drives that must be configured.
Which RAID configuration would provide the maximum usable space with maximum redundancy?
- A . RAID 10
- B . RAID 5
- C . RAID 50
- D . RAID 0
What type of fans are installed in servers with NVMe storage and GPU configurations?
- A . STD
- B . HPR
- C . LFM
- D . VHP
What is used by the Lifecycle Controller to directly back up the server profile on a 14G Dell EMC PowerEdge server?
- A . vFlash SD card
- B . USB Flash drive
- C . Network share
- D . IDSDM SD card
SPECIAL INSTRUCTIONS
The remaining Part1 questions are associated with four case studies that describe various environments or settings. Each case study appears on its own display screen. Questions for each case study will appear on separate display screens. When displaying a question, you can easily review the related case study by clicking on the ‘Review Case Study’ icon shown below:
Case Study 5 – Refer to the Exhibit.
Backing up data from a Dell EMC Isilon cluster exceeds the company’s backup window. Because the company has a large amount of data with a continuous high growth rate, they want to change their backup strategy. The Gen 6 Isilon cluster consists of 24 nodes.
Their current backup strategy is an NDMP three-way backup performing weekly full backups to tape and incremental backups each night. The strategy uses Dell EMC Net Worker. The DMA uses Include paths to specify what data to backup. All data on the cluster must remain accessible.
The company’s IT team is now looking for a method to increase the performance of their backups. After some investigations, you notice that the backup job quiesces the file system. This is creating lock contention issues on open files and not allowing users full access to data when the backup job runs.
What advice should be provided to the team to eliminate lock contention and allow full access to users?
- A . Create a cron job to remove all locks before each backup.
- B . Add A100 Backup Accelerators and configure for three-way NDMP
- C . Stop using an NDMP-based backup strategy.
- D . Enhance the backup strategy using snapshots for backups.
SPECIAL INSTRUCTIONS
The remaining Part1 questions are associated with four case studies that describe various environments or settings. Each case study appears on its own display screen. Questions for each case study will appear on separate display screens. When displaying a question, you can easily review the related case study by clicking on the ‘Review Case Study’ icon shown below:
Case Study 5 – Refer to the Exhibit.
Backing up data from a Dell EMC Isilon cluster exceeds the company’s backup window. Because the company has a large amount of data with a continuous high growth rate, they want to change their backup strategy. The Gen 6 Isilon cluster consists of 24 nodes.
Their current backup strategy is an NDMP three-way backup performing weekly full backups to tape and incremental backups each night. The strategy uses Dell EMC Net Worker. The DMA uses Include paths to specify what data to backup. All data on the cluster must remain accessible.
The company’s IT team is now looking for a method to increase the performance of their backups. After some investigations, you notice that the backup job quiesces the file system. This is creating lock contention issues on open files and not allowing users full access to data when the backup job runs.
What advice should be provided to the team to eliminate lock contention and allow full access to users?
- A . Create a cron job to remove all locks before each backup.
- B . Add A100 Backup Accelerators and configure for three-way NDMP
- C . Stop using an NDMP-based backup strategy.
- D . Enhance the backup strategy using snapshots for backups.
SPECIAL INSTRUCTIONS
The remaining Part1 questions are associated with four case studies that describe various environments or settings. Each case study appears on its own display screen. Questions for each case study will appear on separate display screens. When displaying a question, you can easily review the related case study by clicking on the ‘Review Case Study’ icon shown below:
Case Study 5 – Refer to the Exhibit.
Backing up data from a Dell EMC Isilon cluster exceeds the company’s backup window. Because the company has a large amount of data with a continuous high growth rate, they want to change their backup strategy. The Gen 6 Isilon cluster consists of 24 nodes.
Their current backup strategy is an NDMP three-way backup performing weekly full backups to tape and incremental backups each night. The strategy uses Dell EMC Net Worker. The DMA uses Include paths to specify what data to backup. All data on the cluster must remain accessible.
The company’s IT team is now looking for a method to increase the performance of their backups. After some investigations, you notice that the backup job quiesces the file system. This is creating lock contention issues on open files and not allowing users full access to data when the backup job runs.
What advice should be provided to the team to eliminate lock contention and allow full access to users?
- A . Create a cron job to remove all locks before each backup.
- B . Add A100 Backup Accelerators and configure for three-way NDMP
- C . Stop using an NDMP-based backup strategy.
- D . Enhance the backup strategy using snapshots for backups.
SPECIAL INSTRUCTIONS
The remaining Part1 questions are associated with four case studies that describe various environments or settings. Each case study appears on its own display screen. Questions for each case study will appear on separate display screens. When displaying a question, you can easily review the related case study by clicking on the ‘Review Case Study’ icon shown below:
Case Study 5 – Refer to the Exhibit.
Backing up data from a Dell EMC Isilon cluster exceeds the company’s backup window. Because the company has a large amount of data with a continuous high growth rate, they want to change their backup strategy. The Gen 6 Isilon cluster consists of 24 nodes.
Their current backup strategy is an NDMP three-way backup performing weekly full backups to tape and incremental backups each night. The strategy uses Dell EMC Net Worker. The DMA uses Include paths to specify what data to backup. All data on the cluster must remain accessible.
The company’s IT team is now looking for a method to increase the performance of their backups. After some investigations, you notice that the backup job quiesces the file system. This is creating lock contention issues on open files and not allowing users full access to data when the backup job runs.
What advice should be provided to the team to eliminate lock contention and allow full access to users?
- A . Create a cron job to remove all locks before each backup.
- B . Add A100 Backup Accelerators and configure for three-way NDMP
- C . Stop using an NDMP-based backup strategy.
- D . Enhance the backup strategy using snapshots for backups.
SPECIAL INSTRUCTIONS
The remaining Part1 questions are associated with four case studies that describe various environments or settings. Each case study appears on its own display screen. Questions for each case study will appear on separate display screens. When displaying a question, you can easily review the related case study by clicking on the ‘Review Case Study’ icon shown below:
Case Study 5 – Refer to the Exhibit.
Backing up data from a Dell EMC Isilon cluster exceeds the company’s backup window. Because the company has a large amount of data with a continuous high growth rate, they want to change their backup strategy. The Gen 6 Isilon cluster consists of 24 nodes.
Their current backup strategy is an NDMP three-way backup performing weekly full backups to tape and incremental backups each night. The strategy uses Dell EMC Net Worker. The DMA uses Include paths to specify what data to backup. All data on the cluster must remain accessible.
The company’s IT team is now looking for a method to increase the performance of their backups. After some investigations, you notice that the backup job quiesces the file system. This is creating lock contention issues on open files and not allowing users full access to data when the backup job runs.
What advice should be provided to the team to eliminate lock contention and allow full access to users?
- A . Create a cron job to remove all locks before each backup.
- B . Add A100 Backup Accelerators and configure for three-way NDMP
- C . Stop using an NDMP-based backup strategy.
- D . Enhance the backup strategy using snapshots for backups.
SPECIAL INSTRUCTIONS
The remaining Part1 questions are associated with four case studies that describe various environments or settings. Each case study appears on its own display screen. Questions for each case study will appear on separate display screens. When displaying a question, you can easily review the related case study by clicking on the ‘Review Case Study’ icon shown below:
Case Study 5 – Refer to the Exhibit.
Backing up data from a Dell EMC Isilon cluster exceeds the company’s backup window. Because the company has a large amount of data with a continuous high growth rate, they want to change their backup strategy. The Gen 6 Isilon cluster consists of 24 nodes.
Their current backup strategy is an NDMP three-way backup performing weekly full backups to tape and incremental backups each night. The strategy uses Dell EMC Net Worker. The DMA uses Include paths to specify what data to backup. All data on the cluster must remain accessible.
The company’s IT team is now looking for a method to increase the performance of their backups. After some investigations, you notice that the backup job quiesces the file system. This is creating lock contention issues on open files and not allowing users full access to data when the backup job runs.
What advice should be provided to the team to eliminate lock contention and allow full access to users?
- A . Create a cron job to remove all locks before each backup.
- B . Add A100 Backup Accelerators and configure for three-way NDMP
- C . Stop using an NDMP-based backup strategy.
- D . Enhance the backup strategy using snapshots for backups.
SPECIAL INSTRUCTIONS
The remaining Part1 questions are associated with four case studies that describe various environments or settings. Each case study appears on its own display screen. Questions for each case study will appear on separate display screens. When displaying a question, you can easily review the related case study by clicking on the ‘Review Case Study’ icon shown below:
Case Study 5 – Refer to the Exhibit.
Backing up data from a Dell EMC Isilon cluster exceeds the company’s backup window. Because the company has a large amount of data with a continuous high growth rate, they want to change their backup strategy. The Gen 6 Isilon cluster consists of 24 nodes.
Their current backup strategy is an NDMP three-way backup performing weekly full backups to tape and incremental backups each night. The strategy uses Dell EMC Net Worker. The DMA uses Include paths to specify what data to backup. All data on the cluster must remain accessible.
The company’s IT team is now looking for a method to increase the performance of their backups. After some investigations, you notice that the backup job quiesces the file system. This is creating lock contention issues on open files and not allowing users full access to data when the backup job runs.
What advice should be provided to the team to eliminate lock contention and allow full access to users?
- A . Create a cron job to remove all locks before each backup.
- B . Add A100 Backup Accelerators and configure for three-way NDMP
- C . Stop using an NDMP-based backup strategy.
- D . Enhance the backup strategy using snapshots for backups.
A technician is sent on-site to troubleshoot a server that halts during POST. The iDRAC System Event Log shows the following errors: A bus fatal error was detected on a component at bus 0 device 1 function 1 A bus fatal error was detected on a component at bus 1 device 0 function 0 CPU 1 has an internal error (IERR)
The following system information is provided.
Which system component is the most likely cause?
- A . Processor
- B . Network daughter card
- C . RAID controller
- D . System board
A system administrator plans to use a remote desktop that has the DRAC tools installed to run RACADM commands.
Which two CLI options must be in the RACADM command? (Select 2)
- A . Login credentials
- B . Certificate
- C . IP address of iDRAC
- D . Host OS credentials
Which tool allows an administrator to remotely back up a PowerEdge server configuration to streamline server deployments?
- A . OME
- B . OMSA
- C . iDRAC
- D . Virtual console
Which three steps must a technician take prior to replacing a server component with blue tabs/release? (Choose three.)
- A . Powers off the server
- B . Apply anti-static procedures
- C . Hot-swap the component
- D . Put the server into maintenance mode
- E . Remove power cables
How can a technician know whether IDRAC9 System Lockdown mode is enabled?
- A . Lockdown activation message in red box in the iDRAC web GUI Access to LCC is disabled when the server boots
- B . Lockdown activation message in yellow box in the iDRAC web GUI Access to LCC is disabled when the server boots
- C . Lockdown activation message in red box in the iDRAC web GUI Access to LCC requires a password when the server boots
- D . Lockdown activation message in yellow box in the iDRAC web GUI Access to LCC requires a password when the server boots
Which application reduces the manual effort to update 500 Dell EMC PowerEdge R750 servers?
- A . iDRAC9
- B . Lifecycle Controller
- C . OpenManage Enterprise
- D . OpenManage Server Administrator
An error occurs during data transmission between the CPU and DIMM.
Which feature in a Dell PowerEdge 16G server is responsible for fixing correctable memory errors?
- A . Memory Retraining
- B . Persistent Memory
- C . Post Package Repair
- D . Memory Health Check
What is the minimum version of ESXi that should be used to avoid potential issues writing to the SD cards when running ESXi 7 from an IDSDM?
- A . 7.0 U2e
- B . 7.0 U2c
- C . 7.0 U3g
- D . 7.0 U3c
A technician needs to connect a server to a network but the network switch has only two available network ports so only two network cables can be connected. The user needs as much bandwidth as possible for their workload so the two network cables need to connect to LOM1 and LOM2.
At some point in the future a new network switch will enable additional cables to be used. The technician wants to satisfy the user requirements yet still be able to access the iDRAC without having to reconfigure the iDRAC once new cables are installed in the iDRAC Dedicated NIC.
What is the best way to configure the iDRAC?
- A . Use a splitter cable in one of the network switch ports to connect the same cable to both LOM1 and the iDRAC dedicated NIC
- B . Use a splitter cable in one of the network switch ports to connect the same cable to both LOM1 and LOM2 with the second network cable connecting to the iDRAC dedicated NIC
- C . Set up a dedicated NIC with LOM1 as the NIC selection
- D . Set up a shared NIC with LOM1 as the NIC selection with Auto Dedicated NIC selected
Which two iDRAC license editions support enabling the Lockdown Mode feature? (Select 2)
- A . iDRAC Basic
- B . iDRAC Datacenter
- C . iDRAC Express
- D . iDRAC Enterprise
In which Dell EMC PowerEdge server generation was the BOSS card introduced?
- A . 12G
- B . 13G
- C . 14G
- D . 15G
What image does the iDRAC9 BIOS/UEFI Recovery feature use to flash a corrupt BIOS?
- A . Latest BIOS DUP from the online Dell catalog
- B . Last known good BIOS image
- C . Latest BIOS DUP that the system is aware of
- D . Dell DUP supplied by the system administrator
What operation should a technician perform to ensure configuration recovery if a server must be physically replaced?
- A . Create and export a Server Configuration Profile
- B . Back up the Server Profile to a network share or vFlash SD card
- C . Enable the export configuration option in System Setup
- D . View and export the current hardware inventory
A Dell PowerEdge R740 server with two CPUs has six memory modules that are attached to each CPU. Memory Optimizer mode is configured. The user now wants to have maximum protection for the memory but cannot afford to lose any memory space.
What should be installed or configured?
- A . No additional memory
Switch to Memory Mirroring - B . Six additional memory modules matching the original
Switch on Single Rank Spare Mode - C . Twelve additional memory modules matching the original (six for each CPU)
Switch to Memory Mirroring - D . No additional memory
Switch on Single Rank Spare Mode
When does a customer require the Service Tag of the Dell EMC PowerEdge server?
- A . First time logging in to iDRAC
- B . First time accessing the BIOS
- C . Activating the OS
- D . Obtaining warranty information
A technician needs to install a server with a PERC RAID controller and 24, 2.5" SAS SED drives.
The installation requires the following items to be created:
– Three equal-sized virtual disks
– Encrypted virtual disks
– A global hot spare
In addition to selecting the physical drive to be the hot spare disk, what tasks should the technician perform to set up the RAID controller?
- A . Boot to Ctrl+R and create the three virtual disks
Select each physical drive and enable encryption - B . Boot to F12 and create the three virtual disks
Select each physical drive and enable encryption - C . Boot to F12 and create the three virtual disks
Select each virtual disk and enable encryption - D . Access the iDRAC GUI and create the three virtual disks
Select each virtual disk and enable encryption
Refer to the exhibit.
Match each callout to the Dell EMC PowerEdge server model shown.
A technician deletes the iDRAC Enterprise license on a R640 server.
Which license type is then enabled?
- A . iDRAC Express license
- B . iDRAC will not have a license until a new one is installed
- C . iDRAC Basic license
- D . iDRAC Enterprise license cannot be deleted
Where is the Asset Tag located on the Dell EMC PowerEdge server?
- A . Server chassis
- B . BIOS settings
- C . Dell manufacturing label
- D . Pull-out information tab
A server has the following configuration:
– 5x 1 TB drives configured in a RAID 5 array
– 1x 1 TB as a global hot spare
– Persistent Hot Spare Slot enabled
A user adds one additional 2 TB drive to the existing array using RAID migration.
How much disk space is available to the operating system?
- A . 5 TB
- B . 6 TB
- C . 7 TB
- D . 8 TB
What is a systems management console solution optimized for monitoring and managing Dell enterprise and remote office hardware?
- A . SupportAssist Enterprise
- B . iSM
- C . OpenManage Essentials
- D . iDRAC9
What is a valid password option available from the iDRAC9 Unique ID feature?
- A . Encryption Default
- B . Secure Default
- C . Legacy Generated
- D . Randomly Generated
An administrator is troubleshooting a no power issue on his PowerEdge server. They have confirmed the cable is "known good," and the LED on the PSU is green.
What is the next step in troubleshooting this issue?
- A . Disable the PSU hot spare.
- B . Ensure the power supply is RAF.
- C . Reseat the power supply.
- D . Replace the power supply.
A technician needs to improve overall server performance. All servers run a Dell-supported version of RedHat Linux. Turbo boost has been highly beneficial. CPU performance should be maximized, but not at the expense of power usage.
What is the most efficient way to implement these profile options?
- A . In iDRAC, under Hardware Overview > System Performance, select Performance mode
- B . In System BIOS Settings, select Performance per Watt (Operating System)
- C . In System BIOS Settings, select Performance per Watt (Dell Active Power Control)
- D . In iDRAC, under Hardware > CPU, enable Turbo mode and Dell Active Power Control
What are key characteristics of SupportAssist Enterprise on Dell EMC PowerEdge 14G servers?
- A . System generated
Proactive
Predictive - B . Automated
Proactive
Predictive - C . Manual intervention
Steady state
Remediation - D . Automated
Steady state
Predictive
A technician creates two virtual disks and assigns a dedicated hot spare to each virtual disk. The technician also creates a global hot spare. A drive fails on the second virtual disk.
What is the result?
- A . The dedicated hot spare for the virtual disk replaces the failed drive.
- B . The global hot spare replaces the failed drive.
- C . A copyback operation occurs between the failed drive and the dedicated hot spare.
- D . A copyback operation occurs between the failed drive and the global hot spare.
What category of error is indicated by HWC8011?
- A . Configuration validation error
- B . Uncorrectable memory error
- C . Voltage irregularity error
- D . Dell diagnostics error
What is the drive characteristic of a BOSS M.2 drive in a Dell EMC PowerEdge server?
- A . Single-level cell
- B . Write Intensive
- C . Quad-level cell
- D . Read Intensive
One of the servers in a datacenter is set to use the 1+1 power redundancy option with a hot spare. The server uses 1100W PSUs. An SNMP trap has been sent alerting the technician to a PSU failure.
Since this is the "hot spare" PSU, the technician chooses an available, higher capacity Titanium PSU. After replacing the PSU and connecting the power cable, the PSU indicator/handle flashes green, then turns off.
The technician has taken the following actions:
– Reseated the PSU
– Checked the firmware version
– Checked the cable connections
The PSU continues to flash green then turn off.
What should the technician do?
- A . Check the Titanium PSU in another server to ensure it is not defective
- B . Wait for the PSU firmware to update
- C . Replace the 1100W PSU with a matching unit
- D . Change the redundancy from 1+1 to 2+0 and then enable the hot spare
A technician needs to troubleshoot a server. The OS was operational. After an untrained person accesses the System Setup utility on the server, the OS now fails to load.
The technician reboots the server, selects F2, accesses the System Setup utility, and selects System BIOS. The technician needs to verify items in the System BIOS settings before reloading the OS.
Which two items should the technician verify? (Choose two.)
- A . Boot Settings > Boot Option Settings > Boot Sequence
- B . Device Settings > Boot Sequence
- C . Integrated Devices > OS Watchdog Timer
- D . Boot Settings > Boot Mode
A technician must use the iDRAC UI to roll back a diagnostics firmware revision on a server that was updated four weeks previously. However, the replaced version cannot be found in the Firmware Rollback section on the iDRAC UI.
What is the cause of this issue?
- A . The Rollback feature was not enabled in iDRAC Settings.
- B . Diagnostics firmware is not supported in the Rollback feature.
- C . The Lifecycle Controller was not updated before the rollback.
- D . Firmware can only be rolled back within a week of being replaced.
A technician has a server in production. The iDRAC SEL log indicates a possible issue with DIMMs A1 and A2. Firmware is up to date.
What is the most efficient way to troubleshoot this issue?
- A . Reseat DIMMs A1 and A2
- B . Swap DIMMs A1 and A2 to B1 and B2
- C . Swap DIMMs A1 and A2 to A3 and A4
- D . Swap DIMMs A1 and A2 to B1 and B3
A company that has very specific firmware requirements has acquired Dell EMC PowerEdge servers Any replaced parts of the type must match the original parts identically. The procedure must be as simple as possible with minimal risk.
What action should a technician take to help accomplish this goal?
- A . Configure servers to access the remote firmware repository
- B . Enable the Match Firmware of Replaced Part setting in the system BIOS
- C . Install and configure a repository manager
- D . Enable the Collect System Inventory On Restart (CSIOR) attribute
What is a custom form factor mezzanine card that contains a complete NIC subsystem?
- A . PCIe
- B . LOM
- C . OCP
- D . SNAP I/O
A technician builds a bootable ISO with Repository Manager, and then mounts the ISO via the iDRAC virtual console. After the updates have completed, the technician reboots the server to apply the updates. When reviewing the updates, the technician determines NOT all updates were applied.
What is causing this issue?
- A . The iDRAC update caused virtual media disconnect.
- B . A SUU repository must be used to update the firmware instead of the bootable ISO.
- C . An OS was NOT installed prior to upgrading the firmware.
- D . The firmware must be manually updated from the iDRAC.
A technician is changing the iDRAC IP address from the static IP address 10.37.125.88 to DHCP on the technician’s PowerEdge R640 that does not have a front LCD. After completing this task, they are unable to determine which IP address was given to the iDRAC and they cannot reboot the server.
What method could the technician use to determine what IP address is assigned to the iDRAC?
- A . Use the iDRAC Direct feature. Access iDRAC web GUI and determine the assigned IP address
- B . Plug a monitor or KVM into the system. Reboot the server to view the assigned IP iDRAC address on the Dell boot up splash screen
- C . Log in to the Lifecycle and check the iDRAC Settings.
- D . Hold the system identification button down for more than 3 seconds to reset it back to the default static address 192.168.0.120
What are two ways to check on the health status of a server? (Select 2)
- A . iDRAC Dashboard
- B . System BIOS
- C . Front panel LEDs
- D . iDRAC Settings Overview
- E . Job Queue
What is the result when iDRAC is in Lockdown Mode?
- A . iDRAC is only accessible to administrators.
- B . The virtual console is not accessible.
- C . Local iDRAC users have read-only access.
- D . Lifecycle Controller is inaccessible.
Starting from which Dell EMC PowerEdge server hardware generation is the Micro SD card in the IDSDM/vFlash module supported?
- A . 11G
- B . 12G
- C . 13G
- D . 14G
While working on a Dell EMC PowerEdge R640 server, a technician accidently removes two fans at the same time.
What should happen to the server?
- A . Remaining fans increase RPM to compensate for the removed fans
LCD changes to amber and displays an error message
Server stays operational - B . Remaining fans stay at the recommended RPM
iDRAC slows down the speed of the CPUs to avoid a temperature increase
LCD changes to blue but an alert would have been sent out - C . Remaining fans increase RPM to compensate for the removed fans
LCD changes to amber and displays an error message
Server performs a controlled shutdown - D . Remaining fans increase RPM to compensate for the removed fans
LCD changes to blue and displays an error description
Server performs a controlled shutdown
An existing server is transferred to a new location. When the iDRAC port is plugged into the network, it causes an IP conflict. The technician is directed to change iDRAC settings via the LCD Front Panel Display. There is NO option to make changes.
What is the most probable cause of this issue?
- A . The LCD Front Panel Display can only be used for initial iDRAC configuration.
- B . iDRAC settings can NOT be changed from LCD Front Panel once the OS has started.
- C . LCD Front Panel Display functionality has been limited to view only state in iDRAC
- D . iDRAC port settings can NOT be configured via LCD Front Panel Display.
A technician receives a repurposed PowerEdge server. After racking and cabling the server, they attempt to log into the iDRAC but cannot do so. The default login account has been disabled.
What method can be used to enable the default login account?
- A . Run the racadm racreset command from the host OS
- B . Boot to F2 and select iDRAC Settings > Reset iDRAC configurations to defaults all
- C . Hold down the i button for 16 seconds
- D . SSH into the iDRAC and run the racadm racreset command
What is the maximum number of local iDRAC users that can be created?
- A . 32
- B . 4
- C . 16
- D . 8
A technician needs to replace a server component with orange tabs/releases.
Which two steps should the technician take to complete this task? (Choose two.)
- A . Power off the server
- B . Remove power cables
- C . Cold swap the component
- D . Apply anti-static procedures
- E . Hot swap the component
A technician installs a PCIe Host Bus Adapter in a server, powers on the server, then starts the Lifecycle Controller to update the adapter’s firmware. Before starting the firmware update, they examine the Current Hardware Inventory. The Host Bus Adapter is not visible so it cannot be selected for a firmware update.
How should the technician address this issue?
- A . Power down the server, reseat the adapter, and reboot the server
- B . Perform a server profile backup and reboot the server
- C . Disable Collect Service Inventory on Restart and reboot the server
- D . Enable Collect System Inventory on Restart and reboot the server
What type of screwdriver is required to remove the processor heat sink module?
- A . Torx
- B . Hex
- C . Phillips
- D . Torque
An engineer needs to upgrade a Dell EMC PowerEdge R440 server from a single PSU to dual PSU configuration. There are unused PSU modules from PowerEdge R430 and R420 servers available, and they have the same wattage ratings.
What should the engineer do to complete the task?
- A . Configure the PowerEdge R440 PSU with 1+1 configuration
- B . Order a new PSU specific to the existing PowerEdge R440
- C . Add the PowerEdge R420 PSU modules to the PowerEdge R440
- D . Add the PowerEdge R430 PSU modules to the PowerEdge R440
A server administrator needs to access the iDRAC8 default interface. They are not using DHCP. They open a web browser and prepare to enter an IP address.
What IP address should they use?
- A . https://192.168.120.1
- B . https://192.168.0.120
- C . https://192.168.1.120
- D . https://10.195.2.120
A technician needs to install the OS on a server remotely using iDRAC.
What is the minimum iDRAC license required to perform this task?
- A . Express
- B . Enterprise
- C . Basic
- D . Baseboard Management Controller
A technician needs to configure the Lifecycle Controller network settings with a static IP address. A limited number of static IP addresses are available for use.
Which previously assigned IP address can also be used for the Lifecycle Controller?
- A . The host operating system’s IP address
- B . The iDRAC IP address
- C . The IP address of a different server on the network
- D . The default gateway IP address
Which memory operation modes are supported for a Dell PowerEdge R660?
- A . Optimizer and Persistent Memory
- B . Optimizer and Dell Default Resilient
- C . Optimizer and Mirror
- D . Dell Default Resilient and Mirror
A technician has a 13G system that is giving NO video to a crash cart connected to the front VGA port. The LCD is NOT reporting any errors.
The system reports ‘CPU Resetting’ messages sporadically in the lifecycle log. The iDRAC runs an Express license. The technician needs to most efficiently determine if the system is completing POST despite the video issue.
Which two steps should the technician take to perform this task? (Choose two.)
- A . Reduce to minimum to post
- B . Launch the iDRAC virtual console
- C . Connect to rear VGA port
- D . Hold the system identification button for 6 seconds
A Dell EMC PowerEdge 13G server is being controlled through a secure port by iDRAC8.
What login connection options are available on server using a secure port?
- A . DRM only
- B . RACADM CLI and DRM
- C . Web GUI and RACADM CLI
- D . Web GUI and SSH
A technician needs to analyze a server that is using more power than expected. The server is part of a cluster that runs jobs between 8 AM and 5 PM. The cluster is not used at other times of the day. The server runs an unsupported OS. Performance while jobs are running is a key consideration.
Which option should the technician choose from within System Profile Settings within System Setup to address this issue?
- A . Dense Configuration
- B . Performance Per Watt (DAPC)
- C . Performance
- D . Performance Per Watt (OS)
Case Study 1
A company has several independent business units that operate globally. The company has consolidated its IT infrastructure services and operations. Common infrastructural services which include IPAM, DNS, NTP, DHCP, and SMTP have been consolidated.
The company has complimented its infrastructure development by investing in Dell EMC Isilon clusters to host its user’s home and group directories and for compliance archival purposes required by individual business units. The IT operations are located in India and the United States with its primary data center facilities co-located between New York and Texas.
The company has a total of 60 AD forests:
– 1 main domain
– 55 domains have one-way trust relationships with the main domain
– An additional 4 domains do not have any trust relationship with no future plans of establishing trust relationships with the other domains.
Users of different AD domains use different FQDN to access their corresponding file services. Additionally, the company does not plan to consolidate the AD domains and each domain uses a different IP subnet.
The users of the domains with no trust relationships have a compliance archival requirement. The company wants to all data to be replicated between New York and Texas.
How many tenant Access zones will be required?
- A . 1
- B . 55
- C . 59
- D . 60
A technician needs to update the iDRAC license on a PowerEdge R740 server from Express to Enterprise.
The server has the following components:
– 2x CPUs
– 384 GB RAM
– 6x 1 TB drives
– 1x PSU
The server is powered down but connected to active AC. The user wants it to stay powered down and not connect to any networks. No errors are presently displayed.
How can the technician upgrade the license?
- A . The license cannot be upgraded because the user will not allow the server to be powered on
- B . The license cannot be upgraded on a single PSU system
- C . Power on the server then connect to the iDRAC and upgrade iDRAC license before powering the server down
- D . Connect to the iDRAC GUI and upgrade the iDRAC license while the server is powered down.
Where is the data stored to allow Easy Restore to successfully complete a system board replacement?
- A . NAND Flash module on the disk drive mid plane
- B . IDSDM SD card
- C . vFlash SD card
- D . Serial Flash storage in the server’s front panel
Beginning with which generation Dell EMC PowerEdge server is the NDC available?
- A . 11G
- B . 12G
- C . 13G
- D . 14G
A user installed OME on a PowerEdge R640 server. OME has discovered and is currently monitoring another 30 remote PowerEdge 14G servers.
Each server has the following configuration:
– 2x CPUs
– 384 GB RAM
– 6x 1TB drives in a RAID 6 virtual disk
– No hot spare drive
– PERC
– vFlash
– iDRAC9 Express license
At 9 PM on Monday evening, one of the remote servers has a disk failure but stays operational. The administrator monitoring OME does not find out about the issue until 5 PM in the following Friday. They place a support call to investigate why OME was not informed about the disk failure before then.
What is the reason for this issue not being reported to OME?
- A . Remote servers are not configured with OME as the trap destination address. OME discovered the issue during a routing status check which is configured to run at 5 PM every Friday.
- B . OME only updates its alert database at 5 PM every Friday.
- C . Remote servers are not configured with OME as the trap destination address. OME was informed of the issue when remote servers sent alerts at 5 PM Friday.
- D . Remote servers need to have the iDRAC Enterprise license installed to be able to send alerts.
Which sections are included in the iDRAC Troubleshooting tab?
- A . Post Code, Diagnostics, and Video capture
- B . Diagnostics, Last crash screen, and Post Code
- C . Video capture, Post Code, and Last crash screen
- D . Last crash screen, Video capture, and, Diagnostics
A technician is creating a virtual disk in the DRAC (2x 4 TB NL-SAS in RAID 1) to install Windows 2016. They manually boot to the OS installation media without using the Lifecycle Controller OS Deployment wizard. Only the first 2048 GB on the virtual disk can be partitioned.
How should the technician obtain access to the remaining 2 TB (approximately) of storage?
- A . Delete the 4 TB virtual disk and create a virtual (boot) disk no longer than 2048 GB.
- B . Upgrade to a newer version of the operating system.
- C . Use the lifecycle Controller’s OS Deployment Wizard to deploy the OS on this server.
- D . Use F2 to go into the BIOS, change the BIOS boot mode to UEFI, and try again.
Refer to the exhibit.
A technician tries to apply a BIOS update through the iDRAC web interface on a server using the Linux Dell Update Package file BIOS_2H4CC_LN_2 0.2.BIN. The error shown occurs.
How should this error be fixed?
- A . Download and apply the Windows Dell Update Package file
- B . Extract the Linux Dell Update Package and apply payload file
- C . Redownload the file to replace corrupted version and reinstall
- D . Reset the iDRAC and reapply the update
A technician needs to change the iDRAC password on a Dell EMC PowerEdge 14G server in a lights-out datacenter. The be rebooted because it is in production. The iDRAC is configured with the default credentials.
How could the technician change the iDRAC password?
- A . SupportAssist Enterprise
- B . iDRAC Web GUI
- C . OpenManage Server Administrator
- D . Virtual Console; press F2 after rebooting system
A server is configured in a 1+1 power configuration with both PSUs connected to a single PDU.
Which redundancy options does this configuration supply?
- A . PSU redundancy only
- B . PSU redundancy and PDU redundancy
- C . No redundancy unless each PSU is connected to a separate PDU
- D . PSU redundancy and Grid redundancy
Which two tools provide a user interface to manage the Boot Optimized Storage Solution (BOSS) cards? (Select 2)
- A . OpenManage Mobile (OMM)
- B . Intelligent Platform Management Interface Tool (IPMITool)
- C . Integrated Dell Remote Access Controller (iDRAC)
- D . OpenManage Server Administrator (OMSA)
- E . Remote Access Controller Admin (RACADM)
A technician needs to remotely update the iDRAC with Lifecycle Controller firmware. They have downloaded the latest iDRAC firmware to the management station and connected to the iDRAC GUI.
What step is required to complete the update?
- A . Go to the Summary Page and reset the iDRAC
- B . Boot into the OS via Virtual Console and execute the firmware
- C . Go to the Firmware Update page and upload the iDRAC firmware
- D . Boot the server into F10 to start the firmware update
Case Study 3
A financial services company has file sharing workflows and 2000 home directories which include 70% Microsoft Windows and 30% Linux. The Security team is also interested in credit card usage data analytics such as point of sale, geolocation, and authorization and transaction data. Home directories and file shares do not require D@RE or SEC compliance.
However, due to the sensitivity of the credit card data, the company requires D@RE for credit card information and must adhere to the U.S. SEC 17a-4(f) compliance standards. Additionally, they are interested in auditing user access and anti-virus features.
The compute and storage environment consists of the following:
– 200 TB of Fibre Channel drives on NetApp ONTAP 7
– Environment is expected to grow 200 TB over the next three years
Which combined solution addresses the company’s requirement for D@RE and U.S.SEC 17a-4(f)?
- A . All Flash and SmartLock Compliance mode
- B . SmartLock Enterprise mode and STIG
- C . SED and SmartLock Enterprise mode
- D . SED and SmartLock Compliance mode
Which iDRAC menu includes the detailed log files required to troubleshoot a hardware issue on a Dell EMC PowerEdge server?
- A . Diagnostics
- B . Maintenance
- C . Troubleshooting
- D . System
A technician needs to set a server to always attempt PXE boot before booting to the hard drive.
What two items does the technician need to set to achieve this? (Choose two.)
- A . Remove all boot options except network card
- B . Select PXE Boot from F11 Boot Manager
- C . Change the Boot Sequence so the network card is first
- D . Set the Legacy Boot Protocol for the network card to PXE
An existing server is transferred to a new location. The technician is directed to change the information displayed on the LCD located on the front bezel to show the ambient temperature.
What is a consideration for the technician?
- A . LCD information can be configured for displaying ambient temperature using the iDRAC GUI.
- B . iDRAC Enterprise license must be installed to allow the LCD information to be changed.
- C . Ambient temperature information cannot be displayed on the LCD.
- D . LCD information can only be configured to display the Service Tag and any errors that occur.
Refer to the exhibit.
A system administrator wants to monitor information about the system using their smartphone and a Bluetooth connection. LED labeled 3 on the control panel is solid white.
What does the LED indicate?
- A . The system is powered on.
- B . Quick SYNC 2 is ready to communicate.
- C . OMM is transferring data.
- D . The system is in failsafe mode.
What does OBPAR allow on a PowerEdge MX750c?
- A . Run a compute sled with memory overclocking.
- B . Boot a compute sled with only one CPU.
- C . Run a compute sled with maximum performance.
- D . Boot a compute sled with reduced frequency.
A company’s servers were ordered with iDRAC Enterprise with vFlash. The server profile was backed up after the first boot. Changes have been made to the server BIOS settings and firmware versions, which have resulted in many performance issues.
What is the most efficient way for the technician to address the performance issues?
- A . Upload the approved corporate firmware versions from the file share
- B . Restore system profile using the iDRAC or Lifecycle Controller
- C . Run the racadm racresetcfg command to reset all server settings
- D . Reboot the server to F10 and perform System Repurpose/Retire
A technician resets the iDRAC but when they attempt to log back in to the iDRAC is offline.
Why is the iDRAC offline?
- A . DRAC has reset to the default IP address of 192.168.0.120
- B . Technician must use iDRAC Direct to enable the iDRAC network
- C . iDRAC is still in the reset process
- D . Technician must move the iDRAC network cable back to the iDRAC dedicated NIC
A technician has the ISO image of an OS that they need to install on a server in a remote location. They are already logged into the iDRAC.
How should the technician install the OS?
- A . Click Launch under the Virtual Console Preview, Select Next Boot, and choose Virtual CD/DVD/ISO
- B . Click Launch under the Virtual Console Preview and then connect to Virtual Media
- C . Click Launch under the Virtual Console Preview, reboot the server into F10, and start the Lifecycle Controller OS Deployment wizard
- D . Click on Update and Rollback under Quick Launch Tasks
From PERC8 to PERC9, the maximum number of individual drives upon which a virtual disk can be created changed.
How did this value change?
- A . 8 to 32
- B . 16 to 64
- C . 16 to 32
- D . 8 to 16
A user has a number of PowerEdge servers and installs OME on a remote system to monitor the servers. When attempting to discover one of the servers, the discovery process is unsuccessful. The user accesses the Troubleshooting tool to establish that the communication pathway is correct.
After entering the server iDRAC IP address, which network protocol should be selected to communicate with the iDRAC?
- A . SNMP
- B . IPMI
- C . In-Band
- D . WS-MAN
A technician is tasked to perform a RAID Level Migration (RLM) of a RAID 5 array to a RAID 6 array. They back up data and look in iDRAC Storage and find that the current RAID 5 array is sliced into two virtual disks.
What should the technician do to achieve the desired RAID level?
- A . Reboot and press Ctrl-R to complete RAID migration
- B . Use iDRAC GUI under Storage Configuration to delete the arrays and recreate the new RAID 6 array
- C . Open the OpenManage Enterprise GUI, delete the arrays, and recreate the new RAID 6 array
- D . Use SupportAssist Enterprise to complete RAID migration
A technician needs to initially configure a server from a bare metal condition in the following areas:
– Processor settings
– Disk configuration
– iDRAC network settings
The technician can only reboot once to achieve these tasks.
Where should the technician configure these settings? (Choose three.)
- A . PXE Settings
- B . System BIOS
- C . PERC Configuration Utility
- D . iDRAC Settings
- E . Device Settings
Which characteristic of system management enables a company to reduce costs?
- A . Integration with third-party tools
- B . Multi-tenancy support
- C . Rich management interface
- D . Automation of routine tasks
On a PowerEdge R640 server, the System Lockdown mode has been enabled. Certain features are no longer available in the System BIOS utility or IDRAC GUI.
Which other feature is no longer available?
- A . OMSA
- B . Lifecycle Controller
- C . iSM
- D . Booting to a 32-bit OS
A system administrator is trying to connect with a mobile device to a Dell PowerEdge 16G server using Quick Sync 2. They failed to make a connection.
What is the reason for the failure?
- A . Bluetooth is disabled on the mobile device.
- B . NFC is disabled on the mobile device.
- C . There is no iDRAC IP address configured.
- D . The mobile device is using iOS.
An engineer needs to install an additional PSU on an existing, single PSU Dell EMC PowerEdge R740. They complete the initial installation and cabling procedures. They connect an AC cable and the power distribution unit produces normal AC output. The engineer checks power management and sees that the new PSU is in the Failed state.
What task should be completed to troubleshoot this issue?
- A . Confirm the System Input Power CAP is not set to Low
- B . Set the PSU AC redundancy to 1+1
- C . Set the PSU AC redundancy to 1+0
- D . Verify the new PSU is the same type and wattage rating
A new server with default iDRAC network configurations is plugged into a segregated management network configured for 10.0.0.x/24. The technician cannot connect to the iDRAC.
How can the on-site technician configure the iDRAC for network access?
- A . Change iDRAC network settings from a workstation on the management network
- B . Perform an AC power cycle to reset the iDRAC
- C . Modify the iDRAC settings using the iDRAC Direct feature
- D . Configure a DHCP reservation for the iDRAC MAC address
A technician is deploying a server.
What should they do once the server is fully configured and deployed?
- A . Switch on write-protect for the vFlash SD card
- B . Back up the server profile and reset the iDRAC to Default Settings
- C . Back up the server profile and configure the Parts Replacement feature
- D . Change the iDRAC secure password based on the users’ company policies