DELL EMC D-PE-OE-23 Dell Technologies PowerEdge Operate 2023 Online Training
DELL EMC D-PE-OE-23 Online Training
The questions for D-PE-OE-23 were last updated at Nov 23,2024.
- Exam Code: D-PE-OE-23
- Exam Name: Dell Technologies PowerEdge Operate 2023
- Certification Provider: DELL EMC
- Latest update: Nov 23,2024
While working on a Dell EMC PowerEdge R640 server, a technician accidently removes two fans at the same time.
What should happen to the server?
- A . Remaining fans increase RPM to compensate for the removed fans
LCD changes to amber and displays an error message
Server stays operational - B . Remaining fans stay at the recommended RPM
iDRAC slows down the speed of the CPUs to avoid a temperature increase
LCD changes to blue but an alert would have been sent out - C . Remaining fans increase RPM to compensate for the removed fans
LCD changes to amber and displays an error message
Server performs a controlled shutdown - D . Remaining fans increase RPM to compensate for the removed fans
LCD changes to blue and displays an error description
Server performs a controlled shutdown
An existing server is transferred to a new location. When the iDRAC port is plugged into the network, it causes an IP conflict. The technician is directed to change iDRAC settings via the LCD Front Panel Display. There is NO option to make changes.
What is the most probable cause of this issue?
- A . The LCD Front Panel Display can only be used for initial iDRAC configuration.
- B . iDRAC settings can NOT be changed from LCD Front Panel once the OS has started.
- C . LCD Front Panel Display functionality has been limited to view only state in iDRAC
- D . iDRAC port settings can NOT be configured via LCD Front Panel Display.
A technician receives a repurposed PowerEdge server. After racking and cabling the server, they attempt to log into the iDRAC but cannot do so. The default login account has been disabled.
What method can be used to enable the default login account?
- A . Run the racadm racreset command from the host OS
- B . Boot to F2 and select iDRAC Settings > Reset iDRAC configurations to defaults all
- C . Hold down the i button for 16 seconds
- D . SSH into the iDRAC and run the racadm racreset command
What is the maximum number of local iDRAC users that can be created?
- A . 32
- B . 4
- C . 16
- D . 8
A technician needs to replace a server component with orange tabs/releases.
Which two steps should the technician take to complete this task? (Choose two.)
- A . Power off the server
- B . Remove power cables
- C . Cold swap the component
- D . Apply anti-static procedures
- E . Hot swap the component
A technician installs a PCIe Host Bus Adapter in a server, powers on the server, then starts the Lifecycle Controller to update the adapter’s firmware. Before starting the firmware update, they examine the Current Hardware Inventory. The Host Bus Adapter is not visible so it cannot be selected for a firmware update.
How should the technician address this issue?
- A . Power down the server, reseat the adapter, and reboot the server
- B . Perform a server profile backup and reboot the server
- C . Disable Collect Service Inventory on Restart and reboot the server
- D . Enable Collect System Inventory on Restart and reboot the server
What type of screwdriver is required to remove the processor heat sink module?
- A . Torx
- B . Hex
- C . Phillips
- D . Torque
An engineer needs to upgrade a Dell EMC PowerEdge R440 server from a single PSU to dual PSU configuration. There are unused PSU modules from PowerEdge R430 and R420 servers available, and they have the same wattage ratings.
What should the engineer do to complete the task?
- A . Configure the PowerEdge R440 PSU with 1+1 configuration
- B . Order a new PSU specific to the existing PowerEdge R440
- C . Add the PowerEdge R420 PSU modules to the PowerEdge R440
- D . Add the PowerEdge R430 PSU modules to the PowerEdge R440
A server administrator needs to access the iDRAC8 default interface. They are not using DHCP. They open a web browser and prepare to enter an IP address.
What IP address should they use?
- A . https://192.168.120.1
- B . https://192.168.0.120
- C . https://192.168.1.120
- D . https://10.195.2.120
A technician needs to install the OS on a server remotely using iDRAC.
What is the minimum iDRAC license required to perform this task?
- A . Express
- B . Enterprise
- C . Basic
- D . Baseboard Management Controller