DELL EMC D-PE-OE-23 Dell Technologies PowerEdge Operate 2023 Online Training
DELL EMC D-PE-OE-23 Online Training
The questions for D-PE-OE-23 were last updated at Nov 23,2024.
- Exam Code: D-PE-OE-23
- Exam Name: Dell Technologies PowerEdge Operate 2023
- Certification Provider: DELL EMC
- Latest update: Nov 23,2024
A technician needs to troubleshoot a server. The OS was operational. After an untrained person accesses the System Setup utility on the server, the OS now fails to load.
The technician reboots the server, selects F2, accesses the System Setup utility, and selects System BIOS. The technician needs to verify items in the System BIOS settings before reloading the OS.
Which two items should the technician verify? (Choose two.)
- A . Boot Settings > Boot Option Settings > Boot Sequence
- B . Device Settings > Boot Sequence
- C . Integrated Devices > OS Watchdog Timer
- D . Boot Settings > Boot Mode
A technician must use the iDRAC UI to roll back a diagnostics firmware revision on a server that was updated four weeks previously. However, the replaced version cannot be found in the Firmware Rollback section on the iDRAC UI.
What is the cause of this issue?
- A . The Rollback feature was not enabled in iDRAC Settings.
- B . Diagnostics firmware is not supported in the Rollback feature.
- C . The Lifecycle Controller was not updated before the rollback.
- D . Firmware can only be rolled back within a week of being replaced.
A technician has a server in production. The iDRAC SEL log indicates a possible issue with DIMMs A1 and A2. Firmware is up to date.
What is the most efficient way to troubleshoot this issue?
- A . Reseat DIMMs A1 and A2
- B . Swap DIMMs A1 and A2 to B1 and B2
- C . Swap DIMMs A1 and A2 to A3 and A4
- D . Swap DIMMs A1 and A2 to B1 and B3
A company that has very specific firmware requirements has acquired Dell EMC PowerEdge servers Any replaced parts of the type must match the original parts identically. The procedure must be as simple as possible with minimal risk.
What action should a technician take to help accomplish this goal?
- A . Configure servers to access the remote firmware repository
- B . Enable the Match Firmware of Replaced Part setting in the system BIOS
- C . Install and configure a repository manager
- D . Enable the Collect System Inventory On Restart (CSIOR) attribute
What is a custom form factor mezzanine card that contains a complete NIC subsystem?
- A . PCIe
- B . LOM
- C . OCP
- D . SNAP I/O
A technician builds a bootable ISO with Repository Manager, and then mounts the ISO via the iDRAC virtual console. After the updates have completed, the technician reboots the server to apply the updates. When reviewing the updates, the technician determines NOT all updates were applied.
What is causing this issue?
- A . The iDRAC update caused virtual media disconnect.
- B . A SUU repository must be used to update the firmware instead of the bootable ISO.
- C . An OS was NOT installed prior to upgrading the firmware.
- D . The firmware must be manually updated from the iDRAC.
A technician is changing the iDRAC IP address from the static IP address 10.37.125.88 to DHCP on the technician’s PowerEdge R640 that does not have a front LCD. After completing this task, they are unable to determine which IP address was given to the iDRAC and they cannot reboot the server.
What method could the technician use to determine what IP address is assigned to the iDRAC?
- A . Use the iDRAC Direct feature. Access iDRAC web GUI and determine the assigned IP address
- B . Plug a monitor or KVM into the system. Reboot the server to view the assigned IP iDRAC address on the Dell boot up splash screen
- C . Log in to the Lifecycle and check the iDRAC Settings.
- D . Hold the system identification button down for more than 3 seconds to reset it back to the default static address 192.168.0.120
What are two ways to check on the health status of a server? (Select 2)
- A . iDRAC Dashboard
- B . System BIOS
- C . Front panel LEDs
- D . iDRAC Settings Overview
- E . Job Queue
What is the result when iDRAC is in Lockdown Mode?
- A . iDRAC is only accessible to administrators.
- B . The virtual console is not accessible.
- C . Local iDRAC users have read-only access.
- D . Lifecycle Controller is inaccessible.
Starting from which Dell EMC PowerEdge server hardware generation is the Micro SD card in the IDSDM/vFlash module supported?
- A . 11G
- B . 12G
- C . 13G
- D . 14G