DELL EMC D-PE-OE-23 Dell Technologies PowerEdge Operate 2023 Online Training
DELL EMC D-PE-OE-23 Online Training
The questions for D-PE-OE-23 were last updated at Nov 23,2024.
- Exam Code: D-PE-OE-23
- Exam Name: Dell Technologies PowerEdge Operate 2023
- Certification Provider: DELL EMC
- Latest update: Nov 23,2024
A server has the following configuration:
– 5x 1 TB drives configured in a RAID 5 array
– 1x 1 TB as a global hot spare
– Persistent Hot Spare Slot enabled
A user adds one additional 2 TB drive to the existing array using RAID migration.
How much disk space is available to the operating system?
- A . 5 TB
- B . 6 TB
- C . 7 TB
- D . 8 TB
What is a systems management console solution optimized for monitoring and managing Dell enterprise and remote office hardware?
- A . SupportAssist Enterprise
- B . iSM
- C . OpenManage Essentials
- D . iDRAC9
What is a valid password option available from the iDRAC9 Unique ID feature?
- A . Encryption Default
- B . Secure Default
- C . Legacy Generated
- D . Randomly Generated
An administrator is troubleshooting a no power issue on his PowerEdge server. They have confirmed the cable is "known good," and the LED on the PSU is green.
What is the next step in troubleshooting this issue?
- A . Disable the PSU hot spare.
- B . Ensure the power supply is RAF.
- C . Reseat the power supply.
- D . Replace the power supply.
A technician needs to improve overall server performance. All servers run a Dell-supported version of RedHat Linux. Turbo boost has been highly beneficial. CPU performance should be maximized, but not at the expense of power usage.
What is the most efficient way to implement these profile options?
- A . In iDRAC, under Hardware Overview > System Performance, select Performance mode
- B . In System BIOS Settings, select Performance per Watt (Operating System)
- C . In System BIOS Settings, select Performance per Watt (Dell Active Power Control)
- D . In iDRAC, under Hardware > CPU, enable Turbo mode and Dell Active Power Control
What are key characteristics of SupportAssist Enterprise on Dell EMC PowerEdge 14G servers?
- A . System generated
Proactive
Predictive - B . Automated
Proactive
Predictive - C . Manual intervention
Steady state
Remediation - D . Automated
Steady state
Predictive
A technician creates two virtual disks and assigns a dedicated hot spare to each virtual disk. The technician also creates a global hot spare. A drive fails on the second virtual disk.
What is the result?
- A . The dedicated hot spare for the virtual disk replaces the failed drive.
- B . The global hot spare replaces the failed drive.
- C . A copyback operation occurs between the failed drive and the dedicated hot spare.
- D . A copyback operation occurs between the failed drive and the global hot spare.
What category of error is indicated by HWC8011?
- A . Configuration validation error
- B . Uncorrectable memory error
- C . Voltage irregularity error
- D . Dell diagnostics error
What is the drive characteristic of a BOSS M.2 drive in a Dell EMC PowerEdge server?
- A . Single-level cell
- B . Write Intensive
- C . Quad-level cell
- D . Read Intensive
One of the servers in a datacenter is set to use the 1+1 power redundancy option with a hot spare. The server uses 1100W PSUs. An SNMP trap has been sent alerting the technician to a PSU failure.
Since this is the "hot spare" PSU, the technician chooses an available, higher capacity Titanium PSU. After replacing the PSU and connecting the power cable, the PSU indicator/handle flashes green, then turns off.
The technician has taken the following actions:
– Reseated the PSU
– Checked the firmware version
– Checked the cable connections
The PSU continues to flash green then turn off.
What should the technician do?
- A . Check the Titanium PSU in another server to ensure it is not defective
- B . Wait for the PSU firmware to update
- C . Replace the 1100W PSU with a matching unit
- D . Change the redundancy from 1+1 to 2+0 and then enable the hot spare