DELL EMC D-PE-OE-23 Dell Technologies PowerEdge Operate 2023 Online Training
DELL EMC D-PE-OE-23 Online Training
The questions for D-PE-OE-23 were last updated at Nov 22,2024.
- Exam Code: D-PE-OE-23
- Exam Name: Dell Technologies PowerEdge Operate 2023
- Certification Provider: DELL EMC
- Latest update: Nov 22,2024
A technician needs to perform a RAID controller firmware update from within the Operating System. The server runs Red Hat Enterprise Linux and is configured with an iDRAC basic license.
Which three steps should the technician take to complete this task? (Choose three.)
- A . R estart the server and press F10 t o start the firmware update process
- B . After firmware update, run fsck command on the virtual disks
- C . Obtain the latest firmware update for the RAID controller
- D . Run racadm fwupdate command from a management station
- E . Open a command shell and execute the firmware package
- F . After the firmware update, restart the server
A technician must create a RAID array that uses striping with double parity.
Which RAID level must be used?
- A . RAID 5
- B . RAID 10
- C . RAID 50
- D . RAID 6
A technician installs eight servers into a fully operational rack with top of rack switch Each server has a quad 1Gb NIC and redundant power supplies. The company uses iDRAC in shared LOM mode with LOM1 as the selected NIC.
What should the technician do to verify iDRAC connectivity on each server?
- A . iDRAC Datacenter license is installed.
- B . Ethernet port LOM1 is cabled and the link light is green
- C . iDRAC dedicated NIC port is cabled and the link light is green
- D . iDRAC Enterprise license is installed
Which Dell PowerEdge 16G server has the highest GPU density to run workloads like HPC, AI, DB Analytics, and VDI?
- A . XR4520c
- B . XR7620
- C . XE8545
- D . XE8640
A technician in Portland, Oregon has been asked to update the firmware on a server in Omaha, Nebraska. They will use an NFS server also located in Nebraska for serving patches that have been vetted by their security teams.
What two pieces of information does the technician need in order to access the NFS patch server from the Lifecycle Controller or iDRAC? (Choose two.)
- A . Username and password
- B . CHAP authentication credentials
- C . IP address or hostname
- D . Share name
A remote technician needs to update the iDRAC with Lifecycle Controller firmware using the iDRAC GUI. They have downloaded the iDRAC firmware to the management station and connected to the iDRAC GUI.
What step is required to complete this task?
- A . Reboot the server to apply the update
- B . Boot the server into F10
- C . Start the Lifecycle Controller and select Firmware Update
- D . Use the Firmware Update page to upload and install the firmware
A technician is investigating a server that is reporting that the Lifecycle Controller is disabled during the power-on procedure.
After checking that the system is displaying no other errors, how can the technician re-enable the Lifecycle Controller?
- A . Access the System Setup utility
Select iDRAC Settings and then select Lifecycle Controller
Check the Enable option, save, and reboot the server - B . Enter the iDRAC GUI
Select iDRAC Settings > Lifecycle Controller
Check the Enable option and then power cycle the server - C . Reboot the server
Press F10 during power up and access the Lifecycle Controller GUI
Select Power On Messages, select Enable, and reboot the server - D . Reboot the server and press Ctrl+L during the power on procedure
At the prompt type “LCC-enable”
Select save and reboot the server
A technician wants to install a new version of OMSA onto a server that already has an existing version of OMSA.
What is required for this new installation?
- A . iSM must also be installed on the managed server
- B . iDRAC firmware needs to be at version 5.0 or higher
- C . Existing OMSA version must be disabled in Services
- D . Existing OMSA must be uninstalled before the new version is installed
Eight new servers have arrived at a datacenter. All use static IP addresses for iDRAC. The technician needs to enable these servers to contact the DHCP server on the network to obtain new IP addresses.
What method can the technician use to quickly switch to DHCP?
- A . Reboot each server to enable DHCP default settings
- B . Boot into CTRL+S and change iDRAC settings to DHCP
- C . Use the LCD panel to input a new IP address
- D . Log in to the iDRAC and enable DHCP
Which front disk chassis option is available in a Dell EMC PowerEdge R740 server?
- A . 4x 3.5" drives
- B . 8x 3.5" drives
- C . 12x 2.5" drives
- D . 24x 2.5" drives