DELL EMC D-PE-OE-23 Dell Technologies PowerEdge Operate 2023 Online Training
DELL EMC D-PE-OE-23 Online Training
The questions for D-PE-OE-23 were last updated at Nov 22,2024.
- Exam Code: D-PE-OE-23
- Exam Name: Dell Technologies PowerEdge Operate 2023
- Certification Provider: DELL EMC
- Latest update: Nov 22,2024
A server has six memory modules attached to each CPU Memory Optimizer mode is configured. The user now wants to have maximum protection for the memory but cannot afford to lose any memory space.
What should the technician install/configure?
- A . No additional memory
Switch on Single Rank Spare Mode - B . No additional memory
Switch to memory Mirroring - C . Six additional memory modules matching the original
Switch on Single Rank Spare Mode - D . Six additional memory modules matching the original
Switch to Memory Mirroring
Where is the LCD panel located on a Dell PowerEdge 16G server?
- A . An add-on Server Bezel
- B . Rear of the server
- C . Left control panel
- D . Right control panel
A technician is trying to troubleshoot a server that constantly keeps raising and lowering the RPMs of the fans.
The technician investigates and finds the following:
– No errors are displayed
– No obvious log entries exist concerning temperatures
– Server cover is installed and secured
– No expansion cards are installed
What would be the quickest action plan that the technician could attempt to try to fix the issue with the fans?
- A . Replace all the fans
- B . Upload the latest iDRAC firmware
- C . Replace the fans one at a time until the faulty fan is identified
- D . Adjust the Multi Vector Cooling values
A technician installs a PCIe card into a server, but the card does not appear in the OS. The server does not have an LCD to display errors, but a light is flashing on the front of the server.
What actions can the technician take to troubleshoot the issue?
- A . Initiate Hardware Stress Test from iDRAC GUI
Check PCIe Bus Log for errors - B . Run Hardware Diagnostics from Lifecycle Controller
Review the Lifecycle Controller log for errors - C . Run Hardware Diagnostics from Lifecycle Controller
Initiate Hardware Stress Test from iDRAC GUI - D . Review the Lifecycle Controller log for errors
Check PCIe Bus Log for errors
What is the minimum number of components, beside the system board, required to POST?
- A . 1 PSU, 1 DIMM, and 1 CPU only
- B . 1 PSU, 1 CPU, 1 DIMM, and PERC SAS controller
- C . 1 PSU and 1 CPU only
- D . PSUs, CPUs, and DIMMs as configured in BIOS
Which export type in iDRAC restores a Server Configuration Profile to a known baseline?
- A . Advanced
- B . Replacement
- C . Basic
- D . Clone
A technician is setting up SNMP Trap Alerts on a 14G servers.
After specifying the trap destination address, what should be the next step?
- A . Enable the SMNP Client service on the iDRAC
- B . Include the server OS IP address in the destination systems authentication script
- C . Enable the SMNP services in the server operating system of the sending server
- D . Send an SNMP trap test to the destination system
A technician is installing Windows Server 2016 on a server with RAID 1 and RAID 5 virtual disks.
How should they configure the server and deploy the OS?
- A . Go to system setup to configure both virtual disks
Select the Deploy OS option in the system setup utility - B . Go to Settings in the Lifecycle Controller
Configure both virtual disks using the guided OS installation method - C . Create two virtual disks using the iDRAC UI
Access the Lifecycle Controller
Go to OS deployment using ‘Deploy OS’ - D . Go to the RAID Configuration menu in the Lifecycle Controller
Create both virtual disks
Go to OS deployment using ‘Deploy OS’
What is the maximum number of CPU cores that can be configured in a Dell EMC PowerEdge R6525 server?
- A . 56
- B . 64
- C . 112
- D . 128
A Dell EMC PowerEdge server logs the following CPU Machine Check error: CPU1 IERR.
What action might be required to solve the alert?
- A . Clear logs
- B . Update the Intel driver
- C . Swap the PERC controller
- D . Reseat the IDSDM