Multimode optical fiber is generally used for campus or building applications due to the ability to use cost effective:

Multimode optical fiber is generally used for campus or building applications due to the ability to use cost effective:A . ConnectorsB . CableC . Installation methodsD . TransceiversE . DesignsView AnswerAnswer: D

January 9, 2021 No Comments READ MORE +

In a run requiring 15 m (50 ft) of cable between the floor distributor and the consolidation point, the MAXIMUM length of cable allowed between the CP and the telecommunications outlet is:

In a run requiring 15 m (50 ft) of cable between the floor distributor and the consolidation point, the MAXIMUM length of cable allowed between the CP and the telecommunications outlet is:A . 27.4 m (90 ft)B . 36.5 m (120 ft)C . 45.8 m (150 ft)D . 75 m...

January 9, 2021 No Comments READ MORE +

The standard floor space coverage area for each building automation system (BAS) is a BAS outlet or device for every ________ of floor space.

The standard floor space coverage area for each building automation system (BAS) is a BAS outlet or device for every ________ of floor space.A . 9.3 sq m (100 sq ft)B . 23 sq m (250 sq ft)C . 31 sq m (330 sq ft)D . 56 sq m (600...

January 9, 2021 No Comments READ MORE +

Rack mounted hardware is installed in two standard sized racks or cabinets. Those sizes are:

Rack mounted hardware is installed in two standard sized racks or cabinets. Those sizes are:A . 482 mm (19 in) and 584 mm (23 in)B . 482 mm (19 in) and 762 mm (30 in)C . 610 mm (24 in) and 762 mm (30 in)D . 762 mm (30 in)...

January 9, 2021 No Comments READ MORE +

The ability of a conductors insulation to transmit an electric field is called:

The ability of a conductors insulation to transmit an electric field is called:A . ConductivityB . TransmitabilityC . PermittivityD . CapacitanceE . ReactanceView AnswerAnswer: C

January 9, 2021 No Comments READ MORE +

When installing a heavy backbone cabling vertically, recommended methods of securing the cable include all of the following EXCEPT:

When installing a heavy backbone cabling vertically, recommended methods of securing the cable include all of the following EXCEPT:A . Tie wrapsB . BracketsC . Steel or plastic strapsD . Collar or mesh basket gripsE . Steel cable tiesView AnswerAnswer: A

January 9, 2021 No Comments READ MORE +

When installing outlet boxes in ten private offices in an area which may prove to be difficult to install future additional telecommunications outlets, the MINIMUM quantity of outlet boxes that should be installed is:

When installing outlet boxes in ten private offices in an area which may prove to be difficult to install future additional telecommunications outlets, the MINIMUM quantity of outlet boxes that should be installed is:A . 10B . 20C . 30D . Based on the type of cabling specifiedView AnswerAnswer: B

January 9, 2021 No Comments READ MORE +

Which of the following is the MINIMUM width pull box that is to be provided?

You are designing a horizontal pathway system where you will provide 100 mm (4 in) conduit and pull boxes. The building architectural elements will only allow for a single layer of conduits (not stacked). The main horizontal pathway system consists of five 100 mm (4 in) conduits. Large single sheath...

January 9, 2021 No Comments READ MORE +

Important considerations when designing telecommunications distribution within modular furniture include all of the following EXCEPT:

Important considerations when designing telecommunications distribution within modular furniture include all of the following EXCEPT:A . How the furniture pathways will be connected to horizontal building pathwaysB . Separation of telecommunications cabling and electrical powerC . Diameter of cable to be installedD . Maximum initial fill ratio of 40 percent...

January 9, 2021 No Comments READ MORE +

What is the International Organization for Standardization/International Electrotechnical Commission ISO/IEC class rating for American National Standards Institute/Telecommunication Industry Association (ANSI/TIA) Category 5e cable?

What is the International Organization for Standardization/International Electrotechnical Commission ISO/IEC class rating for American National Standards Institute/Telecommunication Industry Association (ANSI/TIA) Category 5e cable?A . Class BB . Class CC . Class DD . Class EE . Class FView AnswerAnswer: C

January 8, 2021 No Comments READ MORE +