BICSI RCDD-001 BICSI Registered Communications Distribution Designer – RCDD Online Training
BICSI RCDD-001 Online Training
The questions for RCDD-001 were last updated at Apr 27,2025.
- Exam Code: RCDD-001
- Exam Name: BICSI Registered Communications Distribution Designer - RCDD
- Certification Provider: BICSI
- Latest update: Apr 27,2025
Which of the following is NOT an example of a perimeter pathway?
- A . Furniture pathways
- B . Surface raceways
- C . Multi channel raceways
- D . Under carpet cabling
- E . Raceways integrated within walls
When placing an optical fiber cable in the horizontal optical fiber cabling subsystem, what is the MAXIMUM number of splices that can be used?
- A . 1
- B . 2
- C . 3
- D . 4
- E . 5
From a 1000 ft (305 m) roll of optical fiber, how many MAXIMUM length centralized optical fiber cabling runs can be made?
- A . 1
- B . 2
- C . 3
- D . 4
- E . 5
Using the "pathway design" for horizontal cable distribution, how many cable runs are placed to serve 15 individual?
- A . 15
- B . 30
- C . 45
- D . 60
Which of the following is NOT considered acceptable in an information technology system (ITS) conduit design and installation?
- A . Contains no continuous sections longer than 30 m (100 ft)
- B . Bonded to ground on one or both ends in accordance with national or local code requirements
- C . Will withstand the environment to which they were exposed
- D . Uses flexible conduit to access wall outlets
- E . Avoid routing conduit over or adjacent to heat sources
Which of the following is true when describing slip sleeves or gutters?
- A . More costly than pull boxes
- B . Can be used as a splice location
- C . Provides more space for pulling
- D . Cannot be used in place of a pull box
- E . Must be equal in size to the main conduit
The MINIMUM finished height of access flooring in a general office area is:
- A . 50 mm (2 in)
- B . 150 mm (6 in)
- C . 200 mm (8 in)
- D . 250 mm (10 in)
- E . 300 mm (12 in)
Which of the following is NOT an advantage of access floor systems?
- A . They have a low initial cost
- B . They are designed for high capacity
- C . They are aesthetically acceptable for office decor
- D . Cabling is easily accessible across the entire floor
- E . Changes can be made quickly with little occupant disruption
In the ceiling zone method of distribution, the usable floor area should be divided into zones each measuring:
- A . 9.3 sq m (100 sq ft) to 23 sq m (250 sq ft)
- B . 23 sq m (250 sq ft) to 56 sq m (600 sq ft)
- C . 23 sq m (250 sq ft) to 84 sq m (904 sq ft)
- D . 56 sq m (600 sq ft) to 84 sq m (904 sq ft)
- E . 56 sq m (600 sq ft) to 100 sq m (1,100 sq ft)
Which type of cable tray is best described as a ventilated bottom with side rails?
- A . Ventilated channel
- B . Ladder
- C . Spline
- D . Ventilated trough
- E . Basket tray