Which action ensures consistency between the two times?

Refer to the exhibit.

An engineer is troubleshooting BGP on a device but discovers that the clock on the device does not correspond to the time stamp of the log entries.

Which action ensures consistency between the two times?
A . Configure the service timestamps log uptime command in global configuration mode.
B . Configure the logging clock synchronize command in global configuration mode.
C . Configure the service timestamps log datetime localtime command in global configuration mode.
D . Make sure that the clock on the device is synchronized with an NTP server.

Answer: A

Explanation:

https://community.cisco.com/t5/networking-documents/router-log-timestamp-entries-are-

different-from-the-system-clock/ta-p/3132258

Latest 300-410 Dumps Valid Version with 213 Q&As

Latest And Valid Q&A | Instant Download | Once Fail, Full Refund

Subscribe
Notify of
guest
1 Comment
Inline Feedbacks
View all comments
Jeremy
Jeremy
3 years ago

The correct answer is C. By default, the timestamp of syslogs and debug mesages uses UTC regardless the timezone that the device was configured. You have to append the “localtime” keyword to the “service timestamps log datetime msec” and “service timestamps debug datetime msec” to change the behavior.