HP HPE6-A66 Aruba Certified Design Associate Exam Online Training
HP HPE6-A66 Online Training
The questions for HPE6-A66 were last updated at Dec 20,2024.
- Exam Code: HPE6-A66
- Exam Name: Aruba Certified Design Associate Exam
- Certification Provider: HP
- Latest update: Dec 20,2024
When a WLAN has to support nomadic devices, a network architect must primarily plan for which component in their design?
- A . type of users
- B . number of users per location
- C . mobility requirements and usage
- D . density of users
Which two challenges do802.1ig barcode scanners present to a WLAN design? (Select two.)
- A . roaming between APs
- B . encountering RF interference by devices
- C . determining the RF channel bandwidth consumed per Barcode scanner
- D . implementing adequate security measures to ensure PCI compliance
- E . providing consistent performance on all available channels
A network architect is creating a new wireless solution for a customer. Wireless coverage is required throughout all four floors of two buildings on the same campus. Dynamic RF capabilities, including AirMatch, are required. Seamless roaming is required within and between the two buildings. Each floor will have approximately 20 APs and 6 external APs are required for connectivity between the two buildings.
- A . Given this information, which Aruba solution would be the most cost-effective while still meeting the customer’s requirements? O An IAP cluster per floor
- B . A standalone 7008 controller per floor
- C . Two 7205 mobility controllers in a cluster
- D . Two 7030 mobility controllers in a cluster
Which must you perform in IRIS to assign a device to a Design Group?
- A . Right-click the device and select Set Layer Membership
- B . Right-click the device and select Set Design Group
- C . Drag and drop the device into the Site
- D . Drag and drop the device into the Design Group
A network architect is designing a wireless solution for a company that is leasing one floor in a multi-floor building in a downtown area. The customer is concerned about ensuring complete Wi-Fi coverage and pin-pointing RF hazards.
What type of survey should the network architect perform?
- A . Active
- B . Virtual
- C . Passive
- D . Spectrum clearing
A customer placed an order for an ArubaOS 5406R switch and plans to rack mount it in a wiring closet. The dimensions of the switch are 17.5 inches wide (44.45 cm), 6.9 inches high (17.5 cm), and 17.75 inches deep (45.1 cm).
How many rack units should a customer plan for this switch?
- A . 5
- B . 4
- C . 6
- D . 3
A wiring closet with a POE+ switch is 250 feet (76 meters) away from an AP on a building floor. The AP’s smart-rate port is connected to a smart-rate port on the switch, which is capable of 10 Gbps. The cable type is Cat5e STP.
What is the maximum speed that the customer can expect from the connected AP?
- A . 2.5 Gbps
- B . 1 Gbps
- C . 5 Gbps
- D . 10 Gbps
A customer has some employees that travel to various locations, where these employees will need Wi-Fi access at these locations. Because many of these locations do not have wireless support, the employees will need to carry an AP solution with them. Internet connectivity, if it doesn’t exist at these locations, will be provided by a national phone company USB wireless card which will be connected to AP. The wireless solution needs minimal bandwidth, but needs to minimally support 802.1 lac wave 1 devices.
Which Aruba AP wireless solution would meet the needs of these employees most effectively and cost efficiently?
- A . 318
- B . 303H
- C . 365
- D . 203R
NewStellar has a main corporate campus in a business park with two adjacent buildings. Each building has three floors and each floor is 322 x 175 feet (98 x 53 meters) for 56,350 square feet (5,235 square meters) total. The ceiling for each floor is 12 feet (3.6 meters) high with a drop-down ceiling at 10 feet (3 meters).
The network architect has given you one floor to analyze, Building 1 Floor 2, shown in the attached exhibit.
This floor has a central main corridor with washrooms, stairs, elevators and supply and network cabinets. There are cubicles around the perimeter of the floor. The central part main corridor’s dimensions contain 9,350 square feet (870 square meters).
Assuming that wireless coverage is not required in the central area, which square footage (square meter) value should a network architect use when determining the number of APs in a capacity design for each floor?
- A . 55.750 square feet {5,175 square meters)
- B . 56.350 square feet {5,235 square meters)
- C . 47.000 square feet {4,365 square meters)
- D . 338,100 feet {31,410 square meters)
A network architect is redesigning a wireless network. The architect begins by analyzing the number of spatial streams supported by APs of various vendors as well as the wireless devices currently in the network, if the company wants to ensure that new wireless design, including user wireless devices, support Multi-User MIMO (MU-MIMO).
Which standard or standards must the wireless products support?
- A . Only 802.11ax and 8011.ac
- B . Only 802.11ax
- C . Only 802.11ax,802.1lac, and 802.l1n
- D . Only 802.11ax,802.11ac, 802.11n, and 802.11a