BluePrism AD01 Blue Prism Developer Online Training
BluePrism AD01 Online Training
The questions for AD01 were last updated at Nov 22,2024.
- Exam Code: AD01
- Exam Name: Blue Prism Developer
- Certification Provider: BluePrism
- Latest update: Nov 22,2024
Refer to the Exhibit.
The Process is intended to attempt to perform the processing in the recover block, Block 3. a maximum of three times before throwing an exception.
Data Item ‘Attempts’ is a number data item with an initial value of 0 Data Item "Max Attempts" is a number data item with an initial value of 3
The ‘Increment Attempts’ calculation stage add 1 to the attempts value and outputs a result to the "Attempts" data item
To enable this to work correctly, what is the correct expressions for the Try Again’ decision stage?
- A . [Attempts] < [Max]
- B . [Attempts] > [Max]
- C . [Attempts] = [Max]
- D . [Attempts] + 1
Examine the following process flow:
The Orders Collection contains the following data
The Saved Quantity Data Item is configured as a number with the initial value 0.
The Loop Orders stage is configured to loop though the Orders collection.
The Get Quantity stage is configured as follows:
What will the data item Saved Quantity contain after the execution of the page?
- A . 4
- B . 5
- C . 1
- D . 19
How many Start Stages can a sub-page in a Process have?
- A . 0
- B . 1
- C . 2
- D . Any Number
Study the following process flow:
The data item "Loop Counter" is a number data item and has an initial value of 0. The data item "Max Loops" is a number data item and has an initial value of 10.
The two stages are configured as follows:
How many times will the Loop Again stage be executed when the page is executed?
- A . 10
- B . 9
- C . 11
- D . The loop will be infinite
The calculation stages contain the following:
What will be the outcome after the page has run?
- A . Data Item Output Value contains A
- B . Data Item Output Value contains B
- C . Data Item Output Value contains C
- D . An Internal Exception will be thrown
Examine the following process flow:
The Loop Orders loop is configured to loop through the Orders collection.
How Many times will the ‘Process Order’ page be executed?
- A . 1
- B . 15
- C . The loop will be infinite
- D . It’s impossible to tell. There is no loop counter.
Study the following page in a process:
Calculation stages will write A, B or C to the Output value data item.
What will be the outcome after the page has run?
- A . Data Item Output Value contains “A"
- B . Data Item Output Value contains "B"
- C . Data Item Output Value contains "C"
- D . An Internal Exception will be thrown
Study the following process flow:
This is the Mam Page of a simple process which calls the Page Calculation before completing.
The data items are configured as follows:
• X is a Number data item with an initial value of 20
• Y is a Number data item with an initial value of 5
• Result is a Number data item with no initial value
The Calculation Page stage is configured as follows:
The Calculation Page is as follows:
The Data Items are configured as follow:
• X is a Number data item with an initial value of 10
• Y is a Number data item with an initial value of 5
• Result is a Number data item with no initial value
The Start Stage is configured pass through the X and Y values as input parameters.
The divide calculation stage expression is [X] / [Y]
The end stage is configured to pass back the results value as an output parameter.
What will be contained in the Result Data Item on the Mam Page following the execution of the Process?
- A . 0
- B . No Value
- C . 2
- D . 4
Study the following configuration
Which of the following statements is correct?
- A . When the configuration is run in Control Room, it will become stuck in an infinite loop
- B . When the configuration is run in Control Room, it will become stuck in an infinite loop until the ‘Switch’ Session Variable is changed to True in System Manager
- C . When the configuration is run in Control Room, it will become stuck in an infinite loop until the ‘Switch’ Session Variable is changed to True in the Control Room
- D . When the configuration is run in Control Room, it will fail with an internal error on the first execution of the ‘Switch?’ stage with the error: Decision did not result in a yes/no
Consider the following flow in an object:
Which of the following statements are true?
- A . There just needs to be a wait stage after the start stage to correct this action.
- B . There should be a wait stage after every stage in this flow (i.e. after the navigate, read, write stages.
- C . If during testing in object studio this flow works, no additional wait stages should be added as they will slow the interface down.
- D . There should be an intelligent wait stage after the start stage and after any stage that cause the application we are interfacing with to change